Latest Tender Detail from indian army for the tender for rcc foundation by footing , pcc layer , reinforcement , anchor bolts , rcc pedestal , main pole , base plate , gusset plate , display frame , display unit , acp clading , acp border bording , surface treatment , cable management , electrical protection , febrication and welding , excavation , pcc , rcc footing , main reinforcement , distribution ties , concrete cover , anchor template , curing , pole height , gusset plates , rear support grid , fasteners , welding , led module , led cabinet , cabinet fixing , module alignment , receiving card , smps , service access , ventilation , ac distribution , smps input , dc distribution , signal chain , power and signal separation , cable protection , cable entry , earthing , spd , testing , acp sheet , pole cladding , display border , side return depth , corners , joints , bottom closure , ms steel , exposed outdoor steel , welded areas , final colour, installation of digital info display screen for transient and tourist, material dash m20 grade rcc typical size by thickness approx 600 x 600 x 750 mm foundation sized as per soil condition and wind load, material pcc typical size 100 mm thick tech specification dash below rcc footing, material tmt steel typical size dash 12mm mainby 8 dash 10 mm distribution tech specification spacing cage to structual design, material dash gi by hdg typical size dash m16 by m20 tech specification heavy dash duty bolts with nuts and washers, material m20 rcc typical size approx300 x 300 mm tech specification raised pedestal above finished ground level, material ms by gi squre pipe typical size 100 x 100 x 4 mm tech specification heavy duty single pole support, material ms plate typical size 10-12 mm thick tech specification approx 250 x 250 by 300 x 300 mm final size by engineer, material ms plate typical size as reqd tech specfication strengthening between pole and base plate, material ms by gi squre rectangular pipe typical size 40 x 40 2 mm or 50 x 25 x 2 m tech specification frame fabricated to display dimensions, material led digital signage typical size as per approved design tech specification secure mounted with service access, material exterior grade acp typical size 3 mm tech specification clading on pole and structual frame, material acp folded sheet typical size approx 50 dash 100 mm tech specification neat folded corners and concealed fixing, material primer plus exterior paint hdg typical size as specified tech specification anti corrosion protection for outdor use, material outdoor conduit typical size as required tech specification concealed vertical cable routing through pole, material mcb spd earthing typical size as required tech specification waterproof instalation and proper earthing, material ms gi fabrication typical size as per structural detail tech specification continuous appropriate welds visible welds ground smooth, as per structural drawing firm undisturbed bearing surface, 100 mm thick below rcc footing., m20 grade previous reference approx 600 x 600 x 750 mm final size to be recalculated for actual pole display and wind moment, 12 mm dia tmt bar number spacing and cage arrangement as per structural design, 8 dash10 mm dia tmt spacing as per structural design, as per structural civil design maintain proper cover with spacers chairs, approx 300 x 300 mm raised above finished ground as required, m16 m20 gi or hdg quantity diameter grade and bolt pattern as per base plate calculation, ms template plate keep bolt centers accurate during rcc casting, proper curing after casting not load erect before adequate concrete strength is achieved, 100 x100 x 4 mm ms gi square tube single pole support final section by engineer, approx 12 ft above ground final height according to visibility and structural design, 10 dash12 mm ms plate typical 250 x 250 or 300 x 300 mm final plate by calculation, ms plate typically 6 dash 10 mm provided at polebase connection as required, 40x40x2 mm or 50x25x2 mm ms gi rigid perimeter intermediate members spacing to match cabinet module fixing points, ms gi square rectangular tube size grade according to connection design provide locking arrangement where required, high strength gi hdg bolts nuts & washers locking arrangement where required, qualified ms gi fabrication proper structural welds exposed visible welds to be ground smooth, common outdoor module format 320 x 160 mm fix into manufacturer approved cabinet module receiving surface, common modular cabinet formats approx. 960 x 960 mm or 960 x 640 mm use exact cabinet size supplied with selected led system, ms gi rear frame suitable brackets fasteners align cabinet rows columns level faces and maintain uniform joints, row by row column bycolumn correct orientation and pixelpitch continuity, inside cabinet signal orientation according to selected receiving card manufacturer arrangement, inside cabinet protected rear compartment quantity and wattage based on actual led load, rear or front service maintain safe clearance for module smps and receiving card maintenance, natural forced ventilation as cabinet design requires avoid blocked heat dissipation, dedicated protected supply mcb isolator sized from calculated load, properly rated outdoor cable to each cabinet section, manufacturer-approved dc wires connectors correct polarity and cable size, controller sending system receiving cards module data chain, route power and signal wiring neatly avoid unnecessary parallel runs, uv/weather resistant conduit flexible conduit or suitable cable protection, weatherproof glands sealed entries and drip loops, bond metal structure and electrical equipment as required by electrical design, surge protection recommended selected according to electrical design, continuity polarity insulation earthing signal sequence and full display load test, 3 mm exterior grade acp approved colour texture, 3 mm acp folded panels neat folded returns concealed mechanically secure fixing, approx 50 100 mm visible border uniform width around display, as per actual cabinet frame depth measure before acp folding, folded bent where practical clean aligned corners, exteriorgrade neutralcure silicone approved sealant weather sealed neat finish, acp closure skirting as required keep drainageservice access where needed, clean degrease suitable anti corrosion primer exterior-grade top coat, prefer hot dip galvanizing where specified otherwise suitable epoxy pu paint system, clean slag spatter grind where appropriate and prime repaired areas before top coat, as per approved branding design ensure coating finish is compatible with primer in tawang, arunachal pradesh,. Reference number 17806862. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!
Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.