corrigendum tender for 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp, vrf ac work at sme hazratganj, supply of air cooled 20 hp outdoor units suitable for cooling and heating. refer technical specification and boq for details., supply of 5 ceiling suspended 4-way vrf/vrv cassette type 2.0 tr indoor unit in in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply of ceiling suspended 4-way vrf/vrv cassette type 1.3 tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply installation of joints, installation, testing and commissioning of vrf 20hp outdoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 2.0 tr indoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 1.3 tr indoor with gas etc. including making good of damages complete in all respects., commisioning of complete vrf system with all machines, supply, installation, testing and commissioning of interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. refer technical specification and boq for details., ms sloted angle for pipe paying, supply and installation of robust ms angle, ms flat fabricated floor/ wall mounting stand suitable for 20 hp vrf outdoor units. refer technical specification and boq for details.

Latest Tender Detail from state bank of india SBI for the corrigendum tender for 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp, vrf ac work at sme hazratganj, supply of air cooled 20 hp outdoor units suitable for cooling and heating. refer technical specification and boq for details., supply of 5 ceiling suspended 4-way vrf/vrv cassette type 2.0 tr indoor unit in in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply of ceiling suspended 4-way vrf/vrv cassette type 1.3 tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply installation of joints, installation, testing and commissioning of vrf 20hp outdoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 2.0 tr indoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 1.3 tr indoor with gas etc. including making good of damages complete in all respects., commisioning of complete vrf system with all machines, supply, installation, testing and commissioning of interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. refer technical specification and boq for details., ms sloted angle for pipe paying, supply and installation of robust ms angle, ms flat fabricated floor/ wall mounting stand suitable for 20 hp vrf outdoor units. refer technical specification and boq for details. in lucknow, uttar pradesh,. Reference number 15996315. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!

T18 Ref No:15996315
Tender ID:GEM/2026/B/7667301
Tender Agency:state bank of india SBI
City:lucknow
State:uttar pradesh
Tender Related Keywords :supply and installation, refrigerant pipe, water drainage, false ceiling, vrf system, drain pipe, water pipe, ms angle, ms flat, vrf ac
Description :total quantity = 545 ----- document required from seller = experience criteria,oem authorization certificate ----- evaluation method = total value wise evaluation
Tender Value:1136000
Tender EMD:11000
Tender Fee:Refer Document
Published Date:Jun 26, 2026
Due Date:Jun 29, 2026
Tender Opening Date:Jun 29, 2026
T18 Ref No:15996315Tender Value:1136000
Tender ID:GEM/2026/B/7667301Tender EMD:11000
Tender Agency:state bank of india SBITender Fee:Refer Document
City:lucknowPublished Date:Jun 26, 2026
State:uttar pradeshDue Date:Jun 29, 2026
Tender Related Keywords :supply and installation, refrigerant pipe, water drainage, false ceiling, vrf system, drain pipe, water pipe, ms angle, ms flat, vrf acTender Opening Date:Jun 29, 2026
Description :total quantity = 545 ----- document required from seller = experience criteria,oem authorization certificate ----- evaluation method = total value wise evaluation
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

This Government Tender has been Published  by State bank of india SBI for work related to supply and installation,refrigerant pipe,water drainage,false ceiling,vrf system,drain pipe,water pipe,ms angle,ms flat,vrf ac in Lucknow, Uttar pradesh. The Tender work is corrigendum tender for 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp, vrf ac work at sme hazratganj, supply of air cooled 20 hp outdoor units suitable for cooling and heating. refer technical specification and boq for details., supply of 5 ceiling suspended 4-way vrf/vrv cassette type 2.0 tr indoor unit in in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply of ceiling suspended 4-way vrf/vrv cassette type 1.3 tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply installation of joints, installation, testing and commissioning of vrf 20hp outdoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 2.0 tr indoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 1.3 tr indoor with gas etc. including making good of damages complete in all respects., commisioning of complete vrf system with all machines, supply, installation, testing and commissioning of interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. refer technical specification and boq for details., ms sloted angle for pipe paying, supply and installation of robust ms angle, ms flat fabricated floor/ wall mounting stand suitable for 20 hp vrf outdoor units. refer technical specification and boq for details.. Tender18 Provide this type Government Tender Information on daily basis.


This tender invites eligible contractors, suppliers, manufacturers, consultants, Startups, Msmes, traders and service providers to submit bids for the specified project, supply, service, or work requirement.


Before applying, interested bidders should review the tender scope, eligibility criteria, estimated contract value, important dates, technical requirements, reqired docuent list for bidder and bid submission instructions as per provided in the official tender documents. 


This Verified Information Provide By Tender18 in this page so Bidder Can Easiy  Understanding tender  requirements and bidders can prepare a compliant and competitive tender proposal.

To participate in the corrigendum tender for 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp, vrf ac work at sme hazratganj, supply of air cooled 20 hp outdoor units suitable for cooling and heating. refer technical specification and boq for details., supply of 5 ceiling suspended 4-way vrf/vrv cassette type 2.0 tr indoor unit in in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply of ceiling suspended 4-way vrf/vrv cassette type 1.3 tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply installation of joints, installation, testing and commissioning of vrf 20hp outdoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 2.0 tr indoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 1.3 tr indoor with gas etc. including making good of damages complete in all respects., commisioning of complete vrf system with all machines, supply, installation, testing and commissioning of interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. refer technical specification and boq for details., ms sloted angle for pipe paying, supply and installation of robust ms angle, ms flat fabricated floor/ wall mounting stand suitable for 20 hp vrf outdoor units. refer technical specification and boq for details., bidders should first download and review all available tender documents. These documents generally include the Notice Inviting Tender (NIT), Bill of Quantities (BOQ), technical specifications, eligibility criteria, scope of work, and bid submission instructions.


Tender Governemnt Authorities like State bank of india SBI usually publish these documents on their official eProcurement portals, departmental tender portals, the GeM Tender Portal, or other government procurement platforms or on newspapre. Finding and accessing the correct tender documents across multiple portals can sometimes be time-consuming for bidders. 


To make the process easier, Tender18 provides quick access to the available tender documents related to this Lucknow , Uttar pradesh tender on a single page. Businesses involved in supply and installation,refrigerant pipe,water drainage,false ceiling,vrf system,drain pipe,water pipe,ms angle,ms flat,vrf ac related products, services, or works can conveniently download the relevant documents and review the tender requirements without spending time searching across different procurement portals.

The corrigendum tender for 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp, vrf ac work at sme hazratganj, supply of air cooled 20 hp outdoor units suitable for cooling and heating. refer technical specification and boq for details., supply of 5 ceiling suspended 4-way vrf/vrv cassette type 2.0 tr indoor unit in in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply of ceiling suspended 4-way vrf/vrv cassette type 1.3 tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply installation of joints, installation, testing and commissioning of vrf 20hp outdoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 2.0 tr indoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 1.3 tr indoor with gas etc. including making good of damages complete in all respects., commisioning of complete vrf system with all machines, supply, installation, testing and commissioning of interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. refer technical specification and boq for details., ms sloted angle for pipe paying, supply and installation of robust ms angle, ms flat fabricated floor/ wall mounting stand suitable for 20 hp vrf outdoor units. refer technical specification and boq for details. from Lucknow, Uttar pradesh may be relevant for contractors, suppliers, vendors, manufacturers, consultants, service providers, startups, MSMEs, and other organizations involved in supply and installation,refrigerant pipe,water drainage,false ceiling,vrf system,drain pipe,water pipe,ms angle,ms flat,vrf ac related products, services, or works. However, eligibility to participate depends on the qualification criteria specified by State bank of india SBI in the official tender documents.

Before submitting a bid, interested applicants should carefully review the eligibility conditions, technical requirements, financial criteria, work experience requirements, annual turnover conditions, registrations, certifications, and any other supporting documents required by the tendering authority. The detailed qualification requirements and bidder eligibility criteria are available in the tender notice and related documents provided on this page. 

Ensuring compliance with all eligibility and qualification requirements before bid submission can help bidders avoid disqualification and improve their chances of successful participation in the tender process.

Tende18 provides comprehensive tender bidding services, including a complete tender summary along with a detailed analysis of the Tender Qualification and Eligibility Criteria.

Interested in participating in the corrigendum tender for 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp, vrf ac work at sme hazratganj, supply of air cooled 20 hp outdoor units suitable for cooling and heating. refer technical specification and boq for details., supply of 5 ceiling suspended 4-way vrf/vrv cassette type 2.0 tr indoor unit in in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply of ceiling suspended 4-way vrf/vrv cassette type 1.3 tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply installation of joints, installation, testing and commissioning of vrf 20hp outdoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 2.0 tr indoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 1.3 tr indoor with gas etc. including making good of damages complete in all respects., commisioning of complete vrf system with all machines, supply, installation, testing and commissioning of interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. refer technical specification and boq for details., ms sloted angle for pipe paying, supply and installation of robust ms angle, ms flat fabricated floor/ wall mounting stand suitable for 20 hp vrf outdoor units. refer technical specification and boq for details. issued by State bank of india SBI for supply and installation,refrigerant pipe,water drainage,false ceiling,vrf system,drain pipe,water pipe,ms angle,ms flat,vrf ac related work in Lucknow, Uttar pradesh? TENDER18 provides complete assistance to help businesses understand tender requirements, access tender documents, review eligibility criteria, qualification requirements, important dates, and bid submission guidelines associated with this tender.

Our Tender18 Expert Technical team can assist with vendor and GeM registration on the relevant departmental, eProcurement, GeM, or government tender portal, preparation of technical and financial bid documents, compliance with qualification criteria, document verification, and complete online tender submission support. Whether you are a contractor, supplier, manufacturer, consultant, startup, or MSME working in the field of supply and installation,refrigerant pipe,water drainage,false ceiling,vrf system,drain pipe,water pipe,ms angle,ms flat,vrf ac, Tender18 can help simplify the tender participation process and support you throughout every stage of bidding for this tender. so that tender18 is one the top leading tender consultant in Inda.

1.

Whom should I contact if I have further queries about the Tender scope?

You can fill out the integrated inquiry form below on this detail page to share your company profile. Our consultancy desk will review your query regarding supply and installation,refrigerant pipe,water drainage,false ceiling,vrf system,drain pipe,water pipe,ms angle,ms flat,vrf ac parameters and guide you on how to coordinate efficiently with the procurement team of State bank of india SBI

2.

How can Tender18 assist my business in winning this government contract?

Tender18 provides end-to-end professional bidding support and documentation advisory for corrigendum tender for 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp, vrf ac work at sme hazratganj, supply of air cooled 20 hp outdoor units suitable for cooling and heating. refer technical specification and boq for details., supply of 5 ceiling suspended 4-way vrf/vrv cassette type 2.0 tr indoor unit in in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply of ceiling suspended 4-way vrf/vrv cassette type 1.3 tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply installation of joints, installation, testing and commissioning of vrf 20hp outdoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 2.0 tr indoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 1.3 tr indoor with gas etc. including making good of damages complete in all respects., commisioning of complete vrf system with all machines, supply, installation, testing and commissioning of interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. refer technical specification and boq for details., ms sloted angle for pipe paying, supply and installation of robust ms angle, ms flat fabricated floor/ wall mounting stand suitable for 20 hp vrf outdoor units. refer technical specification and boq for details. . Our senior analysts help you decode the complete project guidelines, manage accurate costing sheets, and complete error-free submissions on the official platform used by State bank of india SBI.

3.

What are the main reasons for a technical tender rejection?

Most online bids face rejection during the initial evaluation round due to avoidable errors like uploading blurred document scans, submitting expired DSCs, or missing critical experience papers required for corrigendum tender for 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp, vrf ac work at sme hazratganj, supply of air cooled 20 hp outdoor units suitable for cooling and heating. refer technical specification and boq for details., supply of 5 ceiling suspended 4-way vrf/vrv cassette type 2.0 tr indoor unit in in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply of ceiling suspended 4-way vrf/vrv cassette type 1.3 tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply installation of joints, installation, testing and commissioning of vrf 20hp outdoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 2.0 tr indoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 1.3 tr indoor with gas etc. including making good of damages complete in all respects., commisioning of complete vrf system with all machines, supply, installation, testing and commissioning of interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. refer technical specification and boq for details., ms sloted angle for pipe paying, supply and installation of robust ms angle, ms flat fabricated floor/ wall mounting stand suitable for 20 hp vrf outdoor units. refer technical specification and boq for details. in Uttar pradesh.

4.

Can contractors located outside the local region participate in this bid?

Eligibility for outstation bidders depends entirely on the terms set inside the document for corrigendum tender for 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp, vrf ac work at sme hazratganj, supply of air cooled 20 hp outdoor units suitable for cooling and heating. refer technical specification and boq for details., supply of 5 ceiling suspended 4-way vrf/vrv cassette type 2.0 tr indoor unit in in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply of ceiling suspended 4-way vrf/vrv cassette type 1.3 tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply installation of joints, installation, testing and commissioning of vrf 20hp outdoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 2.0 tr indoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 1.3 tr indoor with gas etc. including making good of damages complete in all respects., commisioning of complete vrf system with all machines, supply, installation, testing and commissioning of interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. refer technical specification and boq for details., ms sloted angle for pipe paying, supply and installation of robust ms angle, ms flat fabricated floor/ wall mounting stand suitable for 20 hp vrf outdoor units. refer technical specification and boq for details.. While many public sector projects allow national competitive bidding, certain localized works require local offices or specific registration metrics in Lucknow.

5.

Do I need an active GeM Portal registration to apply for this work?

If this procurement is routed through the central marketplace, an active GeM Seller ID is mandatory to supply supply and installation,refrigerant pipe,water drainage,false ceiling,vrf system,drain pipe,water pipe,ms angle,ms flat,vrf ac items. Tender18 offers complete assistance for brand cataloging, profile creation, and vendor assessment required officially by State bank of india SBI

6.

What are the primary legal documents required to submit a valid bid?

To register an eligible bid for these supply and installation,refrigerant pipe,water drainage,false ceiling,vrf system,drain pipe,water pipe,ms angle,ms flat,vrf ac contracts, companies must prepare their core compliance documents. Vendors operating across Uttar pradesh must ensure they possess a valid GST registration, permanent account number (PAN), and active Class-3 Digital Signature Certificates.

7.

What products or services are required for this active work?

This public procurement cycle is specifically looking for qualified vendors and suppliers who can provide high-quality supply and installation,refrigerant pipe,water drainage,false ceiling,vrf system,drain pipe,water pipe,ms angle,ms flat,vrf ac solutions. The operational execution, delivery, and deployment of these materials must be managed locally within the Lucknow region.

8.

Where can I review the estimated cost or budget details for this Tender?

The estimated project cost and budget thresholds can be reviewed directly inside the tender document. Bidders can analyze these qualification files to check if their firm meets the financial capability criteria specified for corrigendum tender for 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp, vrf ac work at sme hazratganj, supply of air cooled 20 hp outdoor units suitable for cooling and heating. refer technical specification and boq for details., supply of 5 ceiling suspended 4-way vrf/vrv cassette type 2.0 tr indoor unit in in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply of ceiling suspended 4-way vrf/vrv cassette type 1.3 tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply installation of joints, installation, testing and commissioning of vrf 20hp outdoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 2.0 tr indoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 1.3 tr indoor with gas etc. including making good of damages complete in all respects., commisioning of complete vrf system with all machines, supply, installation, testing and commissioning of interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. refer technical specification and boq for details., ms sloted angle for pipe paying, supply and installation of robust ms angle, ms flat fabricated floor/ wall mounting stand suitable for 20 hp vrf outdoor units. refer technical specification and boq for details. by State bank of india SBI

9.

How can I download the official BOQ file for this opportunity?

You can download the commercial Bill of Quantities (BOQ) spreadsheet directly using the secure link provided on this page. The BOQ file contains the item descriptions and rate filling forms officially validated for corrigendum tender for 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp, vrf ac work at sme hazratganj, supply of air cooled 20 hp outdoor units suitable for cooling and heating. refer technical specification and boq for details., supply of 5 ceiling suspended 4-way vrf/vrv cassette type 2.0 tr indoor unit in in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply of ceiling suspended 4-way vrf/vrv cassette type 1.3 tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply installation of joints, installation, testing and commissioning of vrf 20hp outdoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 2.0 tr indoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 1.3 tr indoor with gas etc. including making good of damages complete in all respects., commisioning of complete vrf system with all machines, supply, installation, testing and commissioning of interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. refer technical specification and boq for details., ms sloted angle for pipe paying, supply and installation of robust ms angle, ms flat fabricated floor/ wall mounting stand suitable for 20 hp vrf outdoor units. refer technical specification and boq for details. within the Uttar pradesh jurisdiction

10.

How can I find the submission closing date for this contract?

The official timeline and deadline details for corrigendum tender for 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of 20 hp vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 9.5 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp, vrf ac work at sme hazratganj, supply of air cooled 20 hp outdoor units suitable for cooling and heating. refer technical specification and boq for details., supply of 5 ceiling suspended 4-way vrf/vrv cassette type 2.0 tr indoor unit in in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply of ceiling suspended 4-way vrf/vrv cassette type 1.3 tr indoor unit in recessed manner in false ceiling with full function wireless remote and auto restart feature. refer technical specification and boq for details., supply installation of joints, installation, testing and commissioning of vrf 20hp outdoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 2.0 tr indoor with gas etc. including making good of damages complete in all respects., installation, testing and commissioning of vrv/vrf cassette 1.3 tr indoor with gas etc. including making good of damages complete in all respects., commisioning of complete vrf system with all machines, supply, installation, testing and commissioning of interconnecting 28.6 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 22.2 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 19.1 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 15.9 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of interconnecting 9.5 mm refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. size (thickness and diameter) of both copper pipes. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 32 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply, installation, testing and commissioning of pvc 25 mm water pipe with 6 mm thik nitrile rubber insulation and accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages. refer technical specification and boq for details., supply & fixing of control cum transmission wiring of 3 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. refer technical specification and boq for details., ms sloted angle for pipe paying, supply and installation of robust ms angle, ms flat fabricated floor/ wall mounting stand suitable for 20 hp vrf outdoor units. refer technical specification and boq for details. are available inside the detailed notification files. Bidders planning to target this contract in Lucknow should check the official portal schedule early to complete their online technical and financial submission well before the closing hours.

Tender Inquiry