corrigendum tender for material and labour in replacement for acsr , supply and erect steel tubular swaged poles , supply and fixing in replacement of stay assembly , material and labour in replacement cross arms , material and labour for restrainging acsr conductor , prunning of trees of over head , supply and fixing in replacement loop type , supply and fixing in replacement of pin type , excavation in trenches in soft , removal of surplus spoil to a distance , material and labour for pcc , material and labour , cable end termination jointing kit , material and labour for testing , supply testing and laying xlpe , supply and fixing of cable jointing kit for 33 kv, repair and replacement of standby power supply to mrs alongwith connected items, material and labour in replacement for acsr conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent ht lt poles and calculating weight of conductor of size length by adding 3percent extra for sag jointing jumpers etc complete all as specified and directed., supply and erect steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts and screws as specified type 410 sp 55 11 mtr long erecting in position all as specified, supply and fixing in replacement of stay assembly comprising of 7 oblique 2.50mm galvanized ms stay wire of reqd length, fixed to poles with and including of fi clamps made out of fi 40x6mm and nuts bolts washers of suitable size ms stay bow 14mm dia galvanized 40cm long ms galvanised stay rod threaded with nut 16mm dia 21 cm long with washers ms stay plate galvanized 230x30x6mm incl necessary excavation and pcc, material and labour in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint., material and labour for restrainging acsr conductor 33kv ht line providing suitable proper sag all as specified and directed., prunning of trees of over head 33kv ht lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by engr in charge., supply and fixing in replacement loop type porcelain white, brown or green large size with cover dimensions of 90mmx140mm clearance of whole 25.5 mm as specified, supply and fixing in replacement of pin type porcelain white brown or green insulator including one galvanized mild steel spindle two galvanised iron washers and one galvanised nut 50mm height 65mm dia for working pressure 33000 volts grade.all as specified and, excavation in trenches in soft oblique loose soil not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation of poles stay cable pipes etc and getting out complete all as specified., removal of surplus spoil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified., material and labour for pcc 1 ratio 4 ratio 8 type d2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as soecified., material and labour for pcc 1 ratio 3 ratio 6 type d2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as soecified., cable end termination jointing kit for 33 kv earthed grade cable outdoor type heat shrink type joint complete with jointing material and accessories suitable for single core xlpe sqmm and entire satisfaction of engnr-in-charge complete all as specifiedand directed, material and labour for testing of faulty ht cable 33kv by using ht voltage fault locating machine and finding the fault and to be repaired the same including all t and p as required on site complete all as directed., supply testing and laying xlpe insulated, screened pvc bedded galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor 33000 volts earthed grade of size 300 sqmm single core complete, supply and fixing of cable jointing kit for 33 kv earthed grade cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for single core xlpe armoured al conductor cable of size 300 sq mm and entire satisfaction of

Latest Tender Detail from indian army for the corrigendum tender for material and labour in replacement for acsr , supply and erect steel tubular swaged poles , supply and fixing in replacement of stay assembly , material and labour in replacement cross arms , material and labour for restrainging acsr conductor , prunning of trees of over head , supply and fixing in replacement loop type , supply and fixing in replacement of pin type , excavation in trenches in soft , removal of surplus spoil to a distance , material and labour for pcc , material and labour , cable end termination jointing kit , material and labour for testing , supply testing and laying xlpe , supply and fixing of cable jointing kit for 33 kv, repair and replacement of standby power supply to mrs alongwith connected items, material and labour in replacement for acsr conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent ht lt poles and calculating weight of conductor of size length by adding 3percent extra for sag jointing jumpers etc complete all as specified and directed., supply and erect steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts and screws as specified type 410 sp 55 11 mtr long erecting in position all as specified, supply and fixing in replacement of stay assembly comprising of 7 oblique 2.50mm galvanized ms stay wire of reqd length, fixed to poles with and including of fi clamps made out of fi 40x6mm and nuts bolts washers of suitable size ms stay bow 14mm dia galvanized 40cm long ms galvanised stay rod threaded with nut 16mm dia 21 cm long with washers ms stay plate galvanized 230x30x6mm incl necessary excavation and pcc, material and labour in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint., material and labour for restrainging acsr conductor 33kv ht line providing suitable proper sag all as specified and directed., prunning of trees of over head 33kv ht lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by engr in charge., supply and fixing in replacement loop type porcelain white, brown or green large size with cover dimensions of 90mmx140mm clearance of whole 25.5 mm as specified, supply and fixing in replacement of pin type porcelain white brown or green insulator including one galvanized mild steel spindle two galvanised iron washers and one galvanised nut 50mm height 65mm dia for working pressure 33000 volts grade.all as specified and, excavation in trenches in soft oblique loose soil not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation of poles stay cable pipes etc and getting out complete all as specified., removal of surplus spoil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified., material and labour for pcc 1 ratio 4 ratio 8 type d2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as soecified., material and labour for pcc 1 ratio 3 ratio 6 type d2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as soecified., cable end termination jointing kit for 33 kv earthed grade cable outdoor type heat shrink type joint complete with jointing material and accessories suitable for single core xlpe sqmm and entire satisfaction of engnr-in-charge complete all as specifiedand directed, material and labour for testing of faulty ht cable 33kv by using ht voltage fault locating machine and finding the fault and to be repaired the same including all t and p as required on site complete all as directed., supply testing and laying xlpe insulated, screened pvc bedded galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor 33000 volts earthed grade of size 300 sqmm single core complete, supply and fixing of cable jointing kit for 33 kv earthed grade cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for single core xlpe armoured al conductor cable of size 300 sq mm and entire satisfaction of in jammu, jammu & kashmir,. Reference number 16213419. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!

T18 Ref No.
16213419
Tender ID
GEM/2026/B/7753472
Tender Agency
City
Tender Related Keywords
-
Description :
total quantity = 254 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc) ----- evaluation method = total value wise evaluation
T18 Ref No.
16213419
Tender ID
GEM/2026/B/7753472
Tender Value
Refer Document
Tender EMD
Refer Document
Tender Agency
Tender Fee
Refer Document
City
Published Date
Jul 11, 2026
Due Date
Jul 23, 2026
Tender Opening Date
Jul 23, 2026
Tender Related Keywords
-
Description :
total quantity = 254 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc) ----- evaluation method = total value wise evaluation

Get Complete Tender Documents to Participate

Tender NoticeBOQEligibilityEMD DetailsImportant Dates
We take all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Browse GeM Portal Tenders

This Government Tender has been Published  by Indian Army for work related to steel tubular swaged poles,aluminium conductor,cable jointing kit,structural steel,end termination,conductor cable,acsr conductor,cable jointing,electric cable,steel tubular,power supply,al conductor,steel strip,base plate,mild steel,cast iron,stay wire,nut bolts,stay rod,ht cable,ht line,bolts in Jammu, Jammu & Kashmir. The Tender work is corrigendum tender for material and labour in replacement for acsr , supply and erect steel tubular swaged poles , supply and fixing in replacement of stay assembly , material and labour in replacement cross arms , material and labour for restrainging acsr conductor , prunning of trees of over head , supply and fixing in replacement loop type , supply and fixing in replacement of pin type , excavation in trenches in soft , removal of surplus spoil to a distance , material and labour for pcc , material and labour , cable end termination jointing kit , material and labour for testing , supply testing and laying xlpe , supply and fixing of cable jointing kit for 33 kv, repair and replacement of standby power supply to mrs alongwith connected items, material and labour in replacement for acsr conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent ht lt poles and calculating weight of conductor of size length by adding 3percent extra for sag jointing jumpers etc complete all as specified and directed., supply and erect steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts and screws as specified type 410 sp 55 11 mtr long erecting in position all as specified, supply and fixing in replacement of stay assembly comprising of 7 oblique 2.50mm galvanized ms stay wire of reqd length, fixed to poles with and including of fi clamps made out of fi 40x6mm and nuts bolts washers of suitable size ms stay bow 14mm dia galvanized 40cm long ms galvanised stay rod threaded with nut 16mm dia 21 cm long with washers ms stay plate galvanized 230x30x6mm incl necessary excavation and pcc, material and labour in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint., material and labour for restrainging acsr conductor 33kv ht line providing suitable proper sag all as specified and directed., prunning of trees of over head 33kv ht lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by engr in charge., supply and fixing in replacement loop type porcelain white, brown or green large size with cover dimensions of 90mmx140mm clearance of whole 25.5 mm as specified, supply and fixing in replacement of pin type porcelain white brown or green insulator including one galvanized mild steel spindle two galvanised iron washers and one galvanised nut 50mm height 65mm dia for working pressure 33000 volts grade.all as specified and, excavation in trenches in soft oblique loose soil not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation of poles stay cable pipes etc and getting out complete all as specified., removal of surplus spoil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified., material and labour for pcc 1 ratio 4 ratio 8 type d2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as soecified., material and labour for pcc 1 ratio 3 ratio 6 type d2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as soecified., cable end termination jointing kit for 33 kv earthed grade cable outdoor type heat shrink type joint complete with jointing material and accessories suitable for single core xlpe sqmm and entire satisfaction of engnr-in-charge complete all as specifiedand directed, material and labour for testing of faulty ht cable 33kv by using ht voltage fault locating machine and finding the fault and to be repaired the same including all t and p as required on site complete all as directed., supply testing and laying xlpe insulated, screened pvc bedded galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor 33000 volts earthed grade of size 300 sqmm single core complete, supply and fixing of cable jointing kit for 33 kv earthed grade cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for single core xlpe armoured al conductor cable of size 300 sq mm and entire satisfaction of. Tender18 Provide this type Government Tender Information on daily basis.


This tender invites eligible contractors, suppliers, manufacturers, consultants, Startups, Msmes, traders and service providers to submit bids for the specified project, supply, service, or work requirement.


Before applying, interested bidders should review the tender scope, eligibility criteria, estimated contract value, important dates, technical requirements, reqired docuent list for bidder and bid submission instructions as per provided in the official tender documents. 


This Verified Information Provide By Tender18 in this page so Bidder Can Easiy  Understanding tender  requirements and bidders can prepare a compliant and competitive tender proposal.

To participate in the corrigendum tender for material and labour in replacement for acsr , supply and erect steel tubular swaged poles , supply and fixing in replacement of stay assembly , material and labour in replacement cross arms , material and labour for restrainging acsr conductor , prunning of trees of over head , supply and fixing in replacement loop type , supply and fixing in replacement of pin type , excavation in trenches in soft , removal of surplus spoil to a distance , material and labour for pcc , material and labour , cable end termination jointing kit , material and labour for testing , supply testing and laying xlpe , supply and fixing of cable jointing kit for 33 kv, repair and replacement of standby power supply to mrs alongwith connected items, material and labour in replacement for acsr conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent ht lt poles and calculating weight of conductor of size length by adding 3percent extra for sag jointing jumpers etc complete all as specified and directed., supply and erect steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts and screws as specified type 410 sp 55 11 mtr long erecting in position all as specified, supply and fixing in replacement of stay assembly comprising of 7 oblique 2.50mm galvanized ms stay wire of reqd length, fixed to poles with and including of fi clamps made out of fi 40x6mm and nuts bolts washers of suitable size ms stay bow 14mm dia galvanized 40cm long ms galvanised stay rod threaded with nut 16mm dia 21 cm long with washers ms stay plate galvanized 230x30x6mm incl necessary excavation and pcc, material and labour in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint., material and labour for restrainging acsr conductor 33kv ht line providing suitable proper sag all as specified and directed., prunning of trees of over head 33kv ht lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by engr in charge., supply and fixing in replacement loop type porcelain white, brown or green large size with cover dimensions of 90mmx140mm clearance of whole 25.5 mm as specified, supply and fixing in replacement of pin type porcelain white brown or green insulator including one galvanized mild steel spindle two galvanised iron washers and one galvanised nut 50mm height 65mm dia for working pressure 33000 volts grade.all as specified and, excavation in trenches in soft oblique loose soil not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation of poles stay cable pipes etc and getting out complete all as specified., removal of surplus spoil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified., material and labour for pcc 1 ratio 4 ratio 8 type d2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as soecified., material and labour for pcc 1 ratio 3 ratio 6 type d2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as soecified., cable end termination jointing kit for 33 kv earthed grade cable outdoor type heat shrink type joint complete with jointing material and accessories suitable for single core xlpe sqmm and entire satisfaction of engnr-in-charge complete all as specifiedand directed, material and labour for testing of faulty ht cable 33kv by using ht voltage fault locating machine and finding the fault and to be repaired the same including all t and p as required on site complete all as directed., supply testing and laying xlpe insulated, screened pvc bedded galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor 33000 volts earthed grade of size 300 sqmm single core complete, supply and fixing of cable jointing kit for 33 kv earthed grade cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for single core xlpe armoured al conductor cable of size 300 sq mm and entire satisfaction of, bidders should first download and review all available tender documents. These documents generally include the Notice Inviting Tender (NIT), Bill of Quantities (BOQ), technical specifications, eligibility criteria, scope of work, and bid submission instructions.


Tender Governemnt Authorities like Indian Army usually publish these documents on their official eProcurement portals, departmental tender portals, the GeM Tender Portal, or other government procurement platforms or on newspapre. Finding and accessing the correct tender documents across multiple portals can sometimes be time-consuming for bidders. 


To make the process easier, Tender18 provides quick access to the available tender documents related to this Jammu , Jammu & Kashmir tender on a single page. Businesses involved in steel tubular swaged poles,aluminium conductor,cable jointing kit,structural steel,end termination,conductor cable,acsr conductor,cable jointing,electric cable,steel tubular,power supply,al conductor,steel strip,base plate,mild steel,cast iron,stay wire,nut bolts,stay rod,ht cable,ht line,bolts related products, services, or works can conveniently download the relevant documents and review the tender requirements without spending time searching across different procurement portals.

The corrigendum tender for material and labour in replacement for acsr , supply and erect steel tubular swaged poles , supply and fixing in replacement of stay assembly , material and labour in replacement cross arms , material and labour for restrainging acsr conductor , prunning of trees of over head , supply and fixing in replacement loop type , supply and fixing in replacement of pin type , excavation in trenches in soft , removal of surplus spoil to a distance , material and labour for pcc , material and labour , cable end termination jointing kit , material and labour for testing , supply testing and laying xlpe , supply and fixing of cable jointing kit for 33 kv, repair and replacement of standby power supply to mrs alongwith connected items, material and labour in replacement for acsr conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent ht lt poles and calculating weight of conductor of size length by adding 3percent extra for sag jointing jumpers etc complete all as specified and directed., supply and erect steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts and screws as specified type 410 sp 55 11 mtr long erecting in position all as specified, supply and fixing in replacement of stay assembly comprising of 7 oblique 2.50mm galvanized ms stay wire of reqd length, fixed to poles with and including of fi clamps made out of fi 40x6mm and nuts bolts washers of suitable size ms stay bow 14mm dia galvanized 40cm long ms galvanised stay rod threaded with nut 16mm dia 21 cm long with washers ms stay plate galvanized 230x30x6mm incl necessary excavation and pcc, material and labour in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint., material and labour for restrainging acsr conductor 33kv ht line providing suitable proper sag all as specified and directed., prunning of trees of over head 33kv ht lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by engr in charge., supply and fixing in replacement loop type porcelain white, brown or green large size with cover dimensions of 90mmx140mm clearance of whole 25.5 mm as specified, supply and fixing in replacement of pin type porcelain white brown or green insulator including one galvanized mild steel spindle two galvanised iron washers and one galvanised nut 50mm height 65mm dia for working pressure 33000 volts grade.all as specified and, excavation in trenches in soft oblique loose soil not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation of poles stay cable pipes etc and getting out complete all as specified., removal of surplus spoil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified., material and labour for pcc 1 ratio 4 ratio 8 type d2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as soecified., material and labour for pcc 1 ratio 3 ratio 6 type d2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as soecified., cable end termination jointing kit for 33 kv earthed grade cable outdoor type heat shrink type joint complete with jointing material and accessories suitable for single core xlpe sqmm and entire satisfaction of engnr-in-charge complete all as specifiedand directed, material and labour for testing of faulty ht cable 33kv by using ht voltage fault locating machine and finding the fault and to be repaired the same including all t and p as required on site complete all as directed., supply testing and laying xlpe insulated, screened pvc bedded galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor 33000 volts earthed grade of size 300 sqmm single core complete, supply and fixing of cable jointing kit for 33 kv earthed grade cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for single core xlpe armoured al conductor cable of size 300 sq mm and entire satisfaction of from Jammu, Jammu & Kashmir may be relevant for contractors, suppliers, vendors, manufacturers, consultants, service providers, startups, MSMEs, and other organizations involved in steel tubular swaged poles,aluminium conductor,cable jointing kit,structural steel,end termination,conductor cable,acsr conductor,cable jointing,electric cable,steel tubular,power supply,al conductor,steel strip,base plate,mild steel,cast iron,stay wire,nut bolts,stay rod,ht cable,ht line,bolts related products, services, or works. However, eligibility to participate depends on the qualification criteria specified by Indian Army in the official tender documents.

Before submitting a bid, interested applicants should carefully review the eligibility conditions, technical requirements, financial criteria, work experience requirements, annual turnover conditions, registrations, certifications, and any other supporting documents required by the tendering authority. The detailed qualification requirements and bidder eligibility criteria are available in the tender notice and related documents provided on this page. 

Ensuring compliance with all eligibility and qualification requirements before bid submission can help bidders avoid disqualification and improve their chances of successful participation in the tender process.

Tende18 provides comprehensive tender bidding services, including a complete tender summary along with a detailed analysis of the Tender Qualification and Eligibility Criteria.

Interested in participating in the corrigendum tender for material and labour in replacement for acsr , supply and erect steel tubular swaged poles , supply and fixing in replacement of stay assembly , material and labour in replacement cross arms , material and labour for restrainging acsr conductor , prunning of trees of over head , supply and fixing in replacement loop type , supply and fixing in replacement of pin type , excavation in trenches in soft , removal of surplus spoil to a distance , material and labour for pcc , material and labour , cable end termination jointing kit , material and labour for testing , supply testing and laying xlpe , supply and fixing of cable jointing kit for 33 kv, repair and replacement of standby power supply to mrs alongwith connected items, material and labour in replacement for acsr conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent ht lt poles and calculating weight of conductor of size length by adding 3percent extra for sag jointing jumpers etc complete all as specified and directed., supply and erect steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts and screws as specified type 410 sp 55 11 mtr long erecting in position all as specified, supply and fixing in replacement of stay assembly comprising of 7 oblique 2.50mm galvanized ms stay wire of reqd length, fixed to poles with and including of fi clamps made out of fi 40x6mm and nuts bolts washers of suitable size ms stay bow 14mm dia galvanized 40cm long ms galvanised stay rod threaded with nut 16mm dia 21 cm long with washers ms stay plate galvanized 230x30x6mm incl necessary excavation and pcc, material and labour in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint., material and labour for restrainging acsr conductor 33kv ht line providing suitable proper sag all as specified and directed., prunning of trees of over head 33kv ht lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by engr in charge., supply and fixing in replacement loop type porcelain white, brown or green large size with cover dimensions of 90mmx140mm clearance of whole 25.5 mm as specified, supply and fixing in replacement of pin type porcelain white brown or green insulator including one galvanized mild steel spindle two galvanised iron washers and one galvanised nut 50mm height 65mm dia for working pressure 33000 volts grade.all as specified and, excavation in trenches in soft oblique loose soil not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation of poles stay cable pipes etc and getting out complete all as specified., removal of surplus spoil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified., material and labour for pcc 1 ratio 4 ratio 8 type d2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as soecified., material and labour for pcc 1 ratio 3 ratio 6 type d2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as soecified., cable end termination jointing kit for 33 kv earthed grade cable outdoor type heat shrink type joint complete with jointing material and accessories suitable for single core xlpe sqmm and entire satisfaction of engnr-in-charge complete all as specifiedand directed, material and labour for testing of faulty ht cable 33kv by using ht voltage fault locating machine and finding the fault and to be repaired the same including all t and p as required on site complete all as directed., supply testing and laying xlpe insulated, screened pvc bedded galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor 33000 volts earthed grade of size 300 sqmm single core complete, supply and fixing of cable jointing kit for 33 kv earthed grade cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for single core xlpe armoured al conductor cable of size 300 sq mm and entire satisfaction of issued by Indian Army for steel tubular swaged poles,aluminium conductor,cable jointing kit,structural steel,end termination,conductor cable,acsr conductor,cable jointing,electric cable,steel tubular,power supply,al conductor,steel strip,base plate,mild steel,cast iron,stay wire,nut bolts,stay rod,ht cable,ht line,bolts related work in Jammu, Jammu & Kashmir? TENDER18 provides complete assistance to help businesses understand tender requirements, access tender documents, review eligibility criteria, qualification requirements, important dates, and bid submission guidelines associated with this tender.

Our Tender18 Expert Technical team can assist with vendor and GeM registration on the relevant departmental, eProcurement, GeM, or government tender portal, preparation of technical and financial bid documents, compliance with qualification criteria, document verification, and complete online tender submission support. Whether you are a contractor, supplier, manufacturer, consultant, startup, or MSME working in the field of steel tubular swaged poles,aluminium conductor,cable jointing kit,structural steel,end termination,conductor cable,acsr conductor,cable jointing,electric cable,steel tubular,power supply,al conductor,steel strip,base plate,mild steel,cast iron,stay wire,nut bolts,stay rod,ht cable,ht line,bolts, Tender18 can help simplify the tender participation process and support you throughout every stage of bidding for this tender. so that tender18 is one the top leading tender consultant in Inda.

1.

Whom should I contact if I have further queries about the Tender scope?

You can fill out the integrated inquiry form below on this detail page to share your company profile. Our consultancy desk will review your query regarding steel tubular swaged poles,aluminium conductor,cable jointing kit,structural steel,end termination,conductor cable,acsr conductor,cable jointing,electric cable,steel tubular,power supply,al conductor,steel strip,base plate,mild steel,cast iron,stay wire,nut bolts,stay rod,ht cable,ht line,bolts parameters and guide you on how to coordinate efficiently with the procurement team of Indian Army

2.

How can Tender18 assist my business in winning this government contract?

Tender18 provides end-to-end professional bidding support and documentation advisory for Corrigendum Tender For Material And Labour In Replacement For Acsr , Supply And Erect Steel Tubular Swaged Poles , Supply And Fixing In Replacement Of Stay Assembly , Material And Labour In Replacement Cross Arms , Material And Labour For Restrainging Acsr Conductor , Prunning Of Trees Of Over Head , Supply And Fixing In Replacement Loop Type , Supply And Fixing In Replacement Of Pin Type , Excavation In Trenches In Soft , Removal Of Surplus Spoil To A Distance , Material And Labour For Pcc , Material And Labour , Cable End Termination Jointing Kit , Material And Labour For Testing , Supply Testing And Laying Xlpe , Supply And Fixing Of Cable Jointing Kit For 33 Kv, Repair And Replacement Of Standby Power Supply To Mrs Alongwith Connected Items, Material And Labour In Replacement For Acsr Conductor Any Size Drawn Straight Horizontal On Over Head Lines On Existing Poles Including Binding With Insulators Weight Of Conductor Shall Be Measured Straight Horizontal Distance Between Centre Of Two Adjacent Ht Lt Poles And Calculating Weight Of Conductor Of Size Length By Adding 3percent Extra For Sag Jointing Jumpers Etc Complete All As Specified And Directed., Supply And Erect Steel Tubular Swaged Poles Complete With Cast Iron Base Plate, Final Taper Plug, Bolts Nuts And Screws As Specified Type 410 Sp 55 11 Mtr Long Erecting In Position All As Specified, Supply And Fixing In Replacement Of Stay Assembly Comprising Of 7 Oblique 2.50mm Galvanized Ms Stay Wire Of Reqd Length, Fixed To Poles With And Including Of Fi Clamps Made Out Of Fi 40x6mm And Nuts Bolts Washers Of Suitable Size Ms Stay Bow 14mm Dia Galvanized 40cm Long Ms Galvanised Stay Rod Threaded With Nut 16mm Dia 21 Cm Long With Washers Ms Stay Plate Galvanized 230x30x6mm Incl Necessary Excavation And Pcc, Material And Labour In Replacement Cross Arms Bracings Supports Clamps And Back Plates Fabricated From Structural Steel Sections Including Nut Bolts Washers Welding Bending Cold And Hot Drilling Holes For Bolts In Any Shape Or Size As Indicate Or Directed And Inclusive Of One Primer Coat One Under Coat And One Finishing Coat Of Paint., Material And Labour For Restrainging Acsr Conductor 33kv Ht Line Providing Suitable Proper Sag All As Specified And Directed., Prunning Of Trees Of Over Head 33kv Ht Lines By Taking Proper Shutdown & Removing The Same From Site Upto A Distance Of 50 Mtr All As Directed By Engr In Charge., Supply And Fixing In Replacement Loop Type Porcelain White, Brown Or Green Large Size With Cover Dimensions Of 90mmx140mm Clearance Of Whole 25.5 Mm As Specified, Supply And Fixing In Replacement Of Pin Type Porcelain White Brown Or Green Insulator Including One Galvanized Mild Steel Spindle Two Galvanised Iron Washers And One Galvanised Nut 50mm Height 65mm Dia For Working Pressure 33000 Volts Grade.all As Specified And, Excavation In Trenches In Soft Oblique Loose Soil Not Exceeding 1.50 M Wide And Not Exceeding 1.50 M In Depth For Foundation Of Poles Stay Cable Pipes Etc And Getting Out Complete All As Specified., Removal Of Surplus Spoil To A Distance Not Exc. 50m And Depositing Where Directed At A Level Not Exc. 1.5m Above The Starting Point Complete All As Specified., Material And Labour For Pcc 1 Ratio 4 Ratio 8 Type D2 Using 40mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Poles Complete All As Soecified., Material And Labour For Pcc 1 Ratio 3 Ratio 6 Type D2 Using 20mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Stays Complete All As Soecified., Cable End Termination Jointing Kit For 33 Kv Earthed Grade Cable Outdoor Type Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Sqmm And Entire Satisfaction Of Engnr-in-charge Complete All As Specifiedand Directed, Material And Labour For Testing Of Faulty Ht Cable 33kv By Using Ht Voltage Fault Locating Machine And Finding The Fault And To Be Repaired The Same Including All T And P As Required On Site Complete All As Directed., Supply Testing And Laying Xlpe Insulated, Screened Pvc Bedded Galvanised Steel Strip Or Wire Armoured Heavy Duty Electric Cable With Stranded Aluminium Conductor 33000 Volts Earthed Grade Of Size 300 Sqmm Single Core Complete, Supply And Fixing Of Cable Jointing Kit For 33 Kv Earthed Grade Cable For Straight Through Joint Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Armoured Al Conductor Cable Of Size 300 Sq Mm And Entire Satisfaction Of . Our senior analysts help you decode the complete project guidelines, manage accurate costing sheets, and complete error-free submissions on the official platform used by Indian Army.

3.

What are the main reasons for a technical tender rejection?

Most online bids face rejection during the initial evaluation round due to avoidable errors like uploading blurred document scans, submitting expired DSCs, or missing critical experience papers required for Corrigendum Tender For Material And Labour In Replacement For Acsr , Supply And Erect Steel Tubular Swaged Poles , Supply And Fixing In Replacement Of Stay Assembly , Material And Labour In Replacement Cross Arms , Material And Labour For Restrainging Acsr Conductor , Prunning Of Trees Of Over Head , Supply And Fixing In Replacement Loop Type , Supply And Fixing In Replacement Of Pin Type , Excavation In Trenches In Soft , Removal Of Surplus Spoil To A Distance , Material And Labour For Pcc , Material And Labour , Cable End Termination Jointing Kit , Material And Labour For Testing , Supply Testing And Laying Xlpe , Supply And Fixing Of Cable Jointing Kit For 33 Kv, Repair And Replacement Of Standby Power Supply To Mrs Alongwith Connected Items, Material And Labour In Replacement For Acsr Conductor Any Size Drawn Straight Horizontal On Over Head Lines On Existing Poles Including Binding With Insulators Weight Of Conductor Shall Be Measured Straight Horizontal Distance Between Centre Of Two Adjacent Ht Lt Poles And Calculating Weight Of Conductor Of Size Length By Adding 3percent Extra For Sag Jointing Jumpers Etc Complete All As Specified And Directed., Supply And Erect Steel Tubular Swaged Poles Complete With Cast Iron Base Plate, Final Taper Plug, Bolts Nuts And Screws As Specified Type 410 Sp 55 11 Mtr Long Erecting In Position All As Specified, Supply And Fixing In Replacement Of Stay Assembly Comprising Of 7 Oblique 2.50mm Galvanized Ms Stay Wire Of Reqd Length, Fixed To Poles With And Including Of Fi Clamps Made Out Of Fi 40x6mm And Nuts Bolts Washers Of Suitable Size Ms Stay Bow 14mm Dia Galvanized 40cm Long Ms Galvanised Stay Rod Threaded With Nut 16mm Dia 21 Cm Long With Washers Ms Stay Plate Galvanized 230x30x6mm Incl Necessary Excavation And Pcc, Material And Labour In Replacement Cross Arms Bracings Supports Clamps And Back Plates Fabricated From Structural Steel Sections Including Nut Bolts Washers Welding Bending Cold And Hot Drilling Holes For Bolts In Any Shape Or Size As Indicate Or Directed And Inclusive Of One Primer Coat One Under Coat And One Finishing Coat Of Paint., Material And Labour For Restrainging Acsr Conductor 33kv Ht Line Providing Suitable Proper Sag All As Specified And Directed., Prunning Of Trees Of Over Head 33kv Ht Lines By Taking Proper Shutdown & Removing The Same From Site Upto A Distance Of 50 Mtr All As Directed By Engr In Charge., Supply And Fixing In Replacement Loop Type Porcelain White, Brown Or Green Large Size With Cover Dimensions Of 90mmx140mm Clearance Of Whole 25.5 Mm As Specified, Supply And Fixing In Replacement Of Pin Type Porcelain White Brown Or Green Insulator Including One Galvanized Mild Steel Spindle Two Galvanised Iron Washers And One Galvanised Nut 50mm Height 65mm Dia For Working Pressure 33000 Volts Grade.all As Specified And, Excavation In Trenches In Soft Oblique Loose Soil Not Exceeding 1.50 M Wide And Not Exceeding 1.50 M In Depth For Foundation Of Poles Stay Cable Pipes Etc And Getting Out Complete All As Specified., Removal Of Surplus Spoil To A Distance Not Exc. 50m And Depositing Where Directed At A Level Not Exc. 1.5m Above The Starting Point Complete All As Specified., Material And Labour For Pcc 1 Ratio 4 Ratio 8 Type D2 Using 40mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Poles Complete All As Soecified., Material And Labour For Pcc 1 Ratio 3 Ratio 6 Type D2 Using 20mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Stays Complete All As Soecified., Cable End Termination Jointing Kit For 33 Kv Earthed Grade Cable Outdoor Type Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Sqmm And Entire Satisfaction Of Engnr-in-charge Complete All As Specifiedand Directed, Material And Labour For Testing Of Faulty Ht Cable 33kv By Using Ht Voltage Fault Locating Machine And Finding The Fault And To Be Repaired The Same Including All T And P As Required On Site Complete All As Directed., Supply Testing And Laying Xlpe Insulated, Screened Pvc Bedded Galvanised Steel Strip Or Wire Armoured Heavy Duty Electric Cable With Stranded Aluminium Conductor 33000 Volts Earthed Grade Of Size 300 Sqmm Single Core Complete, Supply And Fixing Of Cable Jointing Kit For 33 Kv Earthed Grade Cable For Straight Through Joint Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Armoured Al Conductor Cable Of Size 300 Sq Mm And Entire Satisfaction Of in Jammu & Kashmir.

4.

Can contractors located outside the local region participate in this bid?

Eligibility for outstation bidders depends entirely on the terms set inside the document for Corrigendum Tender For Material And Labour In Replacement For Acsr , Supply And Erect Steel Tubular Swaged Poles , Supply And Fixing In Replacement Of Stay Assembly , Material And Labour In Replacement Cross Arms , Material And Labour For Restrainging Acsr Conductor , Prunning Of Trees Of Over Head , Supply And Fixing In Replacement Loop Type , Supply And Fixing In Replacement Of Pin Type , Excavation In Trenches In Soft , Removal Of Surplus Spoil To A Distance , Material And Labour For Pcc , Material And Labour , Cable End Termination Jointing Kit , Material And Labour For Testing , Supply Testing And Laying Xlpe , Supply And Fixing Of Cable Jointing Kit For 33 Kv, Repair And Replacement Of Standby Power Supply To Mrs Alongwith Connected Items, Material And Labour In Replacement For Acsr Conductor Any Size Drawn Straight Horizontal On Over Head Lines On Existing Poles Including Binding With Insulators Weight Of Conductor Shall Be Measured Straight Horizontal Distance Between Centre Of Two Adjacent Ht Lt Poles And Calculating Weight Of Conductor Of Size Length By Adding 3percent Extra For Sag Jointing Jumpers Etc Complete All As Specified And Directed., Supply And Erect Steel Tubular Swaged Poles Complete With Cast Iron Base Plate, Final Taper Plug, Bolts Nuts And Screws As Specified Type 410 Sp 55 11 Mtr Long Erecting In Position All As Specified, Supply And Fixing In Replacement Of Stay Assembly Comprising Of 7 Oblique 2.50mm Galvanized Ms Stay Wire Of Reqd Length, Fixed To Poles With And Including Of Fi Clamps Made Out Of Fi 40x6mm And Nuts Bolts Washers Of Suitable Size Ms Stay Bow 14mm Dia Galvanized 40cm Long Ms Galvanised Stay Rod Threaded With Nut 16mm Dia 21 Cm Long With Washers Ms Stay Plate Galvanized 230x30x6mm Incl Necessary Excavation And Pcc, Material And Labour In Replacement Cross Arms Bracings Supports Clamps And Back Plates Fabricated From Structural Steel Sections Including Nut Bolts Washers Welding Bending Cold And Hot Drilling Holes For Bolts In Any Shape Or Size As Indicate Or Directed And Inclusive Of One Primer Coat One Under Coat And One Finishing Coat Of Paint., Material And Labour For Restrainging Acsr Conductor 33kv Ht Line Providing Suitable Proper Sag All As Specified And Directed., Prunning Of Trees Of Over Head 33kv Ht Lines By Taking Proper Shutdown & Removing The Same From Site Upto A Distance Of 50 Mtr All As Directed By Engr In Charge., Supply And Fixing In Replacement Loop Type Porcelain White, Brown Or Green Large Size With Cover Dimensions Of 90mmx140mm Clearance Of Whole 25.5 Mm As Specified, Supply And Fixing In Replacement Of Pin Type Porcelain White Brown Or Green Insulator Including One Galvanized Mild Steel Spindle Two Galvanised Iron Washers And One Galvanised Nut 50mm Height 65mm Dia For Working Pressure 33000 Volts Grade.all As Specified And, Excavation In Trenches In Soft Oblique Loose Soil Not Exceeding 1.50 M Wide And Not Exceeding 1.50 M In Depth For Foundation Of Poles Stay Cable Pipes Etc And Getting Out Complete All As Specified., Removal Of Surplus Spoil To A Distance Not Exc. 50m And Depositing Where Directed At A Level Not Exc. 1.5m Above The Starting Point Complete All As Specified., Material And Labour For Pcc 1 Ratio 4 Ratio 8 Type D2 Using 40mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Poles Complete All As Soecified., Material And Labour For Pcc 1 Ratio 3 Ratio 6 Type D2 Using 20mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Stays Complete All As Soecified., Cable End Termination Jointing Kit For 33 Kv Earthed Grade Cable Outdoor Type Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Sqmm And Entire Satisfaction Of Engnr-in-charge Complete All As Specifiedand Directed, Material And Labour For Testing Of Faulty Ht Cable 33kv By Using Ht Voltage Fault Locating Machine And Finding The Fault And To Be Repaired The Same Including All T And P As Required On Site Complete All As Directed., Supply Testing And Laying Xlpe Insulated, Screened Pvc Bedded Galvanised Steel Strip Or Wire Armoured Heavy Duty Electric Cable With Stranded Aluminium Conductor 33000 Volts Earthed Grade Of Size 300 Sqmm Single Core Complete, Supply And Fixing Of Cable Jointing Kit For 33 Kv Earthed Grade Cable For Straight Through Joint Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Armoured Al Conductor Cable Of Size 300 Sq Mm And Entire Satisfaction Of. While many public sector projects allow national competitive bidding, certain localized works require local offices or specific registration metrics in Jammu.

5.

Do I need an active GeM Portal registration to apply for this work?

If this procurement is routed through the central marketplace, an active GeM Seller ID is mandatory to supply steel tubular swaged poles,aluminium conductor,cable jointing kit,structural steel,end termination,conductor cable,acsr conductor,cable jointing,electric cable,steel tubular,power supply,al conductor,steel strip,base plate,mild steel,cast iron,stay wire,nut bolts,stay rod,ht cable,ht line,bolts items. Tender18 offers complete assistance for brand cataloging, profile creation, and vendor assessment required officially by Indian Army

6.

What are the primary legal documents required to submit a valid bid?

To register an eligible bid for these steel tubular swaged poles,aluminium conductor,cable jointing kit,structural steel,end termination,conductor cable,acsr conductor,cable jointing,electric cable,steel tubular,power supply,al conductor,steel strip,base plate,mild steel,cast iron,stay wire,nut bolts,stay rod,ht cable,ht line,bolts contracts, companies must prepare their core compliance documents. Vendors operating across Jammu & Kashmir must ensure they possess a valid GST registration, permanent account number (PAN), and active Class-3 Digital Signature Certificates.

7.

What products or services are required for this active work?

This public procurement cycle is specifically looking for qualified vendors and suppliers who can provide high-quality steel tubular swaged poles,aluminium conductor,cable jointing kit,structural steel,end termination,conductor cable,acsr conductor,cable jointing,electric cable,steel tubular,power supply,al conductor,steel strip,base plate,mild steel,cast iron,stay wire,nut bolts,stay rod,ht cable,ht line,bolts solutions. The operational execution, delivery, and deployment of these materials must be managed locally within the Jammu region.

8.

Where can I review the estimated cost or budget details for this Tender?

The estimated project cost and budget thresholds can be reviewed directly inside the tender document. Bidders can analyze these qualification files to check if their firm meets the financial capability criteria specified for Corrigendum Tender For Material And Labour In Replacement For Acsr , Supply And Erect Steel Tubular Swaged Poles , Supply And Fixing In Replacement Of Stay Assembly , Material And Labour In Replacement Cross Arms , Material And Labour For Restrainging Acsr Conductor , Prunning Of Trees Of Over Head , Supply And Fixing In Replacement Loop Type , Supply And Fixing In Replacement Of Pin Type , Excavation In Trenches In Soft , Removal Of Surplus Spoil To A Distance , Material And Labour For Pcc , Material And Labour , Cable End Termination Jointing Kit , Material And Labour For Testing , Supply Testing And Laying Xlpe , Supply And Fixing Of Cable Jointing Kit For 33 Kv, Repair And Replacement Of Standby Power Supply To Mrs Alongwith Connected Items, Material And Labour In Replacement For Acsr Conductor Any Size Drawn Straight Horizontal On Over Head Lines On Existing Poles Including Binding With Insulators Weight Of Conductor Shall Be Measured Straight Horizontal Distance Between Centre Of Two Adjacent Ht Lt Poles And Calculating Weight Of Conductor Of Size Length By Adding 3percent Extra For Sag Jointing Jumpers Etc Complete All As Specified And Directed., Supply And Erect Steel Tubular Swaged Poles Complete With Cast Iron Base Plate, Final Taper Plug, Bolts Nuts And Screws As Specified Type 410 Sp 55 11 Mtr Long Erecting In Position All As Specified, Supply And Fixing In Replacement Of Stay Assembly Comprising Of 7 Oblique 2.50mm Galvanized Ms Stay Wire Of Reqd Length, Fixed To Poles With And Including Of Fi Clamps Made Out Of Fi 40x6mm And Nuts Bolts Washers Of Suitable Size Ms Stay Bow 14mm Dia Galvanized 40cm Long Ms Galvanised Stay Rod Threaded With Nut 16mm Dia 21 Cm Long With Washers Ms Stay Plate Galvanized 230x30x6mm Incl Necessary Excavation And Pcc, Material And Labour In Replacement Cross Arms Bracings Supports Clamps And Back Plates Fabricated From Structural Steel Sections Including Nut Bolts Washers Welding Bending Cold And Hot Drilling Holes For Bolts In Any Shape Or Size As Indicate Or Directed And Inclusive Of One Primer Coat One Under Coat And One Finishing Coat Of Paint., Material And Labour For Restrainging Acsr Conductor 33kv Ht Line Providing Suitable Proper Sag All As Specified And Directed., Prunning Of Trees Of Over Head 33kv Ht Lines By Taking Proper Shutdown & Removing The Same From Site Upto A Distance Of 50 Mtr All As Directed By Engr In Charge., Supply And Fixing In Replacement Loop Type Porcelain White, Brown Or Green Large Size With Cover Dimensions Of 90mmx140mm Clearance Of Whole 25.5 Mm As Specified, Supply And Fixing In Replacement Of Pin Type Porcelain White Brown Or Green Insulator Including One Galvanized Mild Steel Spindle Two Galvanised Iron Washers And One Galvanised Nut 50mm Height 65mm Dia For Working Pressure 33000 Volts Grade.all As Specified And, Excavation In Trenches In Soft Oblique Loose Soil Not Exceeding 1.50 M Wide And Not Exceeding 1.50 M In Depth For Foundation Of Poles Stay Cable Pipes Etc And Getting Out Complete All As Specified., Removal Of Surplus Spoil To A Distance Not Exc. 50m And Depositing Where Directed At A Level Not Exc. 1.5m Above The Starting Point Complete All As Specified., Material And Labour For Pcc 1 Ratio 4 Ratio 8 Type D2 Using 40mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Poles Complete All As Soecified., Material And Labour For Pcc 1 Ratio 3 Ratio 6 Type D2 Using 20mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Stays Complete All As Soecified., Cable End Termination Jointing Kit For 33 Kv Earthed Grade Cable Outdoor Type Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Sqmm And Entire Satisfaction Of Engnr-in-charge Complete All As Specifiedand Directed, Material And Labour For Testing Of Faulty Ht Cable 33kv By Using Ht Voltage Fault Locating Machine And Finding The Fault And To Be Repaired The Same Including All T And P As Required On Site Complete All As Directed., Supply Testing And Laying Xlpe Insulated, Screened Pvc Bedded Galvanised Steel Strip Or Wire Armoured Heavy Duty Electric Cable With Stranded Aluminium Conductor 33000 Volts Earthed Grade Of Size 300 Sqmm Single Core Complete, Supply And Fixing Of Cable Jointing Kit For 33 Kv Earthed Grade Cable For Straight Through Joint Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Armoured Al Conductor Cable Of Size 300 Sq Mm And Entire Satisfaction Of by Indian Army

9.

How can I download the official BOQ file for this opportunity?

You can download the commercial Bill of Quantities (BOQ) spreadsheet directly using the secure link provided on this page. The BOQ file contains the item descriptions and rate filling forms officially validated for Corrigendum Tender For Material And Labour In Replacement For Acsr , Supply And Erect Steel Tubular Swaged Poles , Supply And Fixing In Replacement Of Stay Assembly , Material And Labour In Replacement Cross Arms , Material And Labour For Restrainging Acsr Conductor , Prunning Of Trees Of Over Head , Supply And Fixing In Replacement Loop Type , Supply And Fixing In Replacement Of Pin Type , Excavation In Trenches In Soft , Removal Of Surplus Spoil To A Distance , Material And Labour For Pcc , Material And Labour , Cable End Termination Jointing Kit , Material And Labour For Testing , Supply Testing And Laying Xlpe , Supply And Fixing Of Cable Jointing Kit For 33 Kv, Repair And Replacement Of Standby Power Supply To Mrs Alongwith Connected Items, Material And Labour In Replacement For Acsr Conductor Any Size Drawn Straight Horizontal On Over Head Lines On Existing Poles Including Binding With Insulators Weight Of Conductor Shall Be Measured Straight Horizontal Distance Between Centre Of Two Adjacent Ht Lt Poles And Calculating Weight Of Conductor Of Size Length By Adding 3percent Extra For Sag Jointing Jumpers Etc Complete All As Specified And Directed., Supply And Erect Steel Tubular Swaged Poles Complete With Cast Iron Base Plate, Final Taper Plug, Bolts Nuts And Screws As Specified Type 410 Sp 55 11 Mtr Long Erecting In Position All As Specified, Supply And Fixing In Replacement Of Stay Assembly Comprising Of 7 Oblique 2.50mm Galvanized Ms Stay Wire Of Reqd Length, Fixed To Poles With And Including Of Fi Clamps Made Out Of Fi 40x6mm And Nuts Bolts Washers Of Suitable Size Ms Stay Bow 14mm Dia Galvanized 40cm Long Ms Galvanised Stay Rod Threaded With Nut 16mm Dia 21 Cm Long With Washers Ms Stay Plate Galvanized 230x30x6mm Incl Necessary Excavation And Pcc, Material And Labour In Replacement Cross Arms Bracings Supports Clamps And Back Plates Fabricated From Structural Steel Sections Including Nut Bolts Washers Welding Bending Cold And Hot Drilling Holes For Bolts In Any Shape Or Size As Indicate Or Directed And Inclusive Of One Primer Coat One Under Coat And One Finishing Coat Of Paint., Material And Labour For Restrainging Acsr Conductor 33kv Ht Line Providing Suitable Proper Sag All As Specified And Directed., Prunning Of Trees Of Over Head 33kv Ht Lines By Taking Proper Shutdown & Removing The Same From Site Upto A Distance Of 50 Mtr All As Directed By Engr In Charge., Supply And Fixing In Replacement Loop Type Porcelain White, Brown Or Green Large Size With Cover Dimensions Of 90mmx140mm Clearance Of Whole 25.5 Mm As Specified, Supply And Fixing In Replacement Of Pin Type Porcelain White Brown Or Green Insulator Including One Galvanized Mild Steel Spindle Two Galvanised Iron Washers And One Galvanised Nut 50mm Height 65mm Dia For Working Pressure 33000 Volts Grade.all As Specified And, Excavation In Trenches In Soft Oblique Loose Soil Not Exceeding 1.50 M Wide And Not Exceeding 1.50 M In Depth For Foundation Of Poles Stay Cable Pipes Etc And Getting Out Complete All As Specified., Removal Of Surplus Spoil To A Distance Not Exc. 50m And Depositing Where Directed At A Level Not Exc. 1.5m Above The Starting Point Complete All As Specified., Material And Labour For Pcc 1 Ratio 4 Ratio 8 Type D2 Using 40mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Poles Complete All As Soecified., Material And Labour For Pcc 1 Ratio 3 Ratio 6 Type D2 Using 20mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Stays Complete All As Soecified., Cable End Termination Jointing Kit For 33 Kv Earthed Grade Cable Outdoor Type Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Sqmm And Entire Satisfaction Of Engnr-in-charge Complete All As Specifiedand Directed, Material And Labour For Testing Of Faulty Ht Cable 33kv By Using Ht Voltage Fault Locating Machine And Finding The Fault And To Be Repaired The Same Including All T And P As Required On Site Complete All As Directed., Supply Testing And Laying Xlpe Insulated, Screened Pvc Bedded Galvanised Steel Strip Or Wire Armoured Heavy Duty Electric Cable With Stranded Aluminium Conductor 33000 Volts Earthed Grade Of Size 300 Sqmm Single Core Complete, Supply And Fixing Of Cable Jointing Kit For 33 Kv Earthed Grade Cable For Straight Through Joint Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Armoured Al Conductor Cable Of Size 300 Sq Mm And Entire Satisfaction Of within the Jammu & Kashmir jurisdiction

10.

How can I find the submission closing date for this contract?

The official timeline and deadline details for Corrigendum Tender For Material And Labour In Replacement For Acsr , Supply And Erect Steel Tubular Swaged Poles , Supply And Fixing In Replacement Of Stay Assembly , Material And Labour In Replacement Cross Arms , Material And Labour For Restrainging Acsr Conductor , Prunning Of Trees Of Over Head , Supply And Fixing In Replacement Loop Type , Supply And Fixing In Replacement Of Pin Type , Excavation In Trenches In Soft , Removal Of Surplus Spoil To A Distance , Material And Labour For Pcc , Material And Labour , Cable End Termination Jointing Kit , Material And Labour For Testing , Supply Testing And Laying Xlpe , Supply And Fixing Of Cable Jointing Kit For 33 Kv, Repair And Replacement Of Standby Power Supply To Mrs Alongwith Connected Items, Material And Labour In Replacement For Acsr Conductor Any Size Drawn Straight Horizontal On Over Head Lines On Existing Poles Including Binding With Insulators Weight Of Conductor Shall Be Measured Straight Horizontal Distance Between Centre Of Two Adjacent Ht Lt Poles And Calculating Weight Of Conductor Of Size Length By Adding 3percent Extra For Sag Jointing Jumpers Etc Complete All As Specified And Directed., Supply And Erect Steel Tubular Swaged Poles Complete With Cast Iron Base Plate, Final Taper Plug, Bolts Nuts And Screws As Specified Type 410 Sp 55 11 Mtr Long Erecting In Position All As Specified, Supply And Fixing In Replacement Of Stay Assembly Comprising Of 7 Oblique 2.50mm Galvanized Ms Stay Wire Of Reqd Length, Fixed To Poles With And Including Of Fi Clamps Made Out Of Fi 40x6mm And Nuts Bolts Washers Of Suitable Size Ms Stay Bow 14mm Dia Galvanized 40cm Long Ms Galvanised Stay Rod Threaded With Nut 16mm Dia 21 Cm Long With Washers Ms Stay Plate Galvanized 230x30x6mm Incl Necessary Excavation And Pcc, Material And Labour In Replacement Cross Arms Bracings Supports Clamps And Back Plates Fabricated From Structural Steel Sections Including Nut Bolts Washers Welding Bending Cold And Hot Drilling Holes For Bolts In Any Shape Or Size As Indicate Or Directed And Inclusive Of One Primer Coat One Under Coat And One Finishing Coat Of Paint., Material And Labour For Restrainging Acsr Conductor 33kv Ht Line Providing Suitable Proper Sag All As Specified And Directed., Prunning Of Trees Of Over Head 33kv Ht Lines By Taking Proper Shutdown & Removing The Same From Site Upto A Distance Of 50 Mtr All As Directed By Engr In Charge., Supply And Fixing In Replacement Loop Type Porcelain White, Brown Or Green Large Size With Cover Dimensions Of 90mmx140mm Clearance Of Whole 25.5 Mm As Specified, Supply And Fixing In Replacement Of Pin Type Porcelain White Brown Or Green Insulator Including One Galvanized Mild Steel Spindle Two Galvanised Iron Washers And One Galvanised Nut 50mm Height 65mm Dia For Working Pressure 33000 Volts Grade.all As Specified And, Excavation In Trenches In Soft Oblique Loose Soil Not Exceeding 1.50 M Wide And Not Exceeding 1.50 M In Depth For Foundation Of Poles Stay Cable Pipes Etc And Getting Out Complete All As Specified., Removal Of Surplus Spoil To A Distance Not Exc. 50m And Depositing Where Directed At A Level Not Exc. 1.5m Above The Starting Point Complete All As Specified., Material And Labour For Pcc 1 Ratio 4 Ratio 8 Type D2 Using 40mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Poles Complete All As Soecified., Material And Labour For Pcc 1 Ratio 3 Ratio 6 Type D2 Using 20mm Graded Broken Stone Aggregate As In Mass Concrete In Foundation Of Stays Complete All As Soecified., Cable End Termination Jointing Kit For 33 Kv Earthed Grade Cable Outdoor Type Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Sqmm And Entire Satisfaction Of Engnr-in-charge Complete All As Specifiedand Directed, Material And Labour For Testing Of Faulty Ht Cable 33kv By Using Ht Voltage Fault Locating Machine And Finding The Fault And To Be Repaired The Same Including All T And P As Required On Site Complete All As Directed., Supply Testing And Laying Xlpe Insulated, Screened Pvc Bedded Galvanised Steel Strip Or Wire Armoured Heavy Duty Electric Cable With Stranded Aluminium Conductor 33000 Volts Earthed Grade Of Size 300 Sqmm Single Core Complete, Supply And Fixing Of Cable Jointing Kit For 33 Kv Earthed Grade Cable For Straight Through Joint Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Single Core Xlpe Armoured Al Conductor Cable Of Size 300 Sq Mm And Entire Satisfaction Of are available inside the detailed notification files. Bidders planning to target this contract in Jammu should check the official portal schedule early to complete their online technical and financial submission well before the closing hours.

Get Expert Tender Bidding Support

Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.

Call Our Expert: +91 7069661818
Your Information Is 100% Secure & Confidential