tender for sac unit , dismantling ac , covering hole , itc of ac , copper pipe , cable , iron structure , ms stand , water pipe , mcb, supply installation testing and commissioning of 10 nos sac for cntx east telephone bhawan kolkata, supply of 1.5 tr inverter type 5 star rated split air conditioner unit having nominal cooling capacity of 4536 kcal per hr , 5275 watts and as per bee star rating minimum iseer of 5.6 with temperature control thermistor , remote control unit , filters , rotary or scroll or swing type compressor , copper tubes for both indoor and outdoor unit , refrigerant gas with topping up of refrigerant if required , transportation of all of the above to various sites and supplying the following upto the length of 3 mtrs etc as reqd. 1. hot and cold refrigerant piping . 2. suitable connecting electrical cable between indoor and outdoor unit . 3 .pvc drain pipe of suitable size . note . 1 . the manufacturers or suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation , which is earlier , thereafter 4 years additional warranty on the compressor and indoor & outdoor units pcb., dismantling of existing split ac unit - indoor and outdoor units along with interconnecting cu pipe and cable, power connection cable etc. and storing at place shown by exch. in charge etc. as reqd., covering the opening in wall by metal plate/cement brick in case of brick wall subsequent to removal of old wac units to avoid any leakage of cool air etc. complete as required., installation, testing and commissioning of 1.5 tr 5 star inverter type split ac unit along with hot and cold refrigerant copper piping, copper conductor flexible connecting electrical cable & pvc drain pipe up to the standard length of 3 mtrs. (as supplied under item 1) including leak testing entire system, gas charging, insulating the refrigerant pipe and making opening in wall and making good the damages, making power supply connections from the power point etc. complete as required., providing and fixing of additional refrigerant copper piping i. e. for hot & cold line of suitable size to match with the pipeline of the new split ac units, over and above 3 mtrs length wherever required along with suitable size rubber foam insulation on surface of the wall including necessary flare nuts, suitably brazing with the existing pipe, clamping, making holes in walls & additional gas charging if required etc. as per site requirement complete as reqd. note - the length of refrigerant pipes supplied with each ac units is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates. only single run will be measured for both i. e. hot gas and cold liquid line refrigerant pipes., supplying and laying 4 core 2.5 sq.mm. pvc insulated and pvc sheathed flexible copper cable along with refrigerant pipe or along with existing conduit or cable tray including binding with plastic tags for extending supply from existing industrial socket to indoor unit etc. as required. make any isi mark . note the length of copper cable supplied with each unit is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates., supplying and fixing of iron stand made out of 40mm x 40mm x 5mm thick angle iron for mounting outdoor unit of the above ac as per manufacturer i/c providing other necessary hardware, painting etc. complete as required., supplying & fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good the damages etc. as per site requirement., supplying and fixing of 25 mm dia isi mark heavy duty pvc pipe with accessories for drain water connection, over and above 3 mtrs length wherever required etc. complete as required., supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required.

Latest Tender Detail from bharat sanchar nigam limited BSNL for the tender for sac unit , dismantling ac , covering hole , itc of ac , copper pipe , cable , iron structure , ms stand , water pipe , mcb, supply installation testing and commissioning of 10 nos sac for cntx east telephone bhawan kolkata, supply of 1.5 tr inverter type 5 star rated split air conditioner unit having nominal cooling capacity of 4536 kcal per hr , 5275 watts and as per bee star rating minimum iseer of 5.6 with temperature control thermistor , remote control unit , filters , rotary or scroll or swing type compressor , copper tubes for both indoor and outdoor unit , refrigerant gas with topping up of refrigerant if required , transportation of all of the above to various sites and supplying the following upto the length of 3 mtrs etc as reqd. 1. hot and cold refrigerant piping . 2. suitable connecting electrical cable between indoor and outdoor unit . 3 .pvc drain pipe of suitable size . note . 1 . the manufacturers or suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation , which is earlier , thereafter 4 years additional warranty on the compressor and indoor & outdoor units pcb., dismantling of existing split ac unit - indoor and outdoor units along with interconnecting cu pipe and cable, power connection cable etc. and storing at place shown by exch. in charge etc. as reqd., covering the opening in wall by metal plate/cement brick in case of brick wall subsequent to removal of old wac units to avoid any leakage of cool air etc. complete as required., installation, testing and commissioning of 1.5 tr 5 star inverter type split ac unit along with hot and cold refrigerant copper piping, copper conductor flexible connecting electrical cable & pvc drain pipe up to the standard length of 3 mtrs. (as supplied under item 1) including leak testing entire system, gas charging, insulating the refrigerant pipe and making opening in wall and making good the damages, making power supply connections from the power point etc. complete as required., providing and fixing of additional refrigerant copper piping i. e. for hot & cold line of suitable size to match with the pipeline of the new split ac units, over and above 3 mtrs length wherever required along with suitable size rubber foam insulation on surface of the wall including necessary flare nuts, suitably brazing with the existing pipe, clamping, making holes in walls & additional gas charging if required etc. as per site requirement complete as reqd. note - the length of refrigerant pipes supplied with each ac units is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates. only single run will be measured for both i. e. hot gas and cold liquid line refrigerant pipes., supplying and laying 4 core 2.5 sq.mm. pvc insulated and pvc sheathed flexible copper cable along with refrigerant pipe or along with existing conduit or cable tray including binding with plastic tags for extending supply from existing industrial socket to indoor unit etc. as required. make any isi mark . note the length of copper cable supplied with each unit is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates., supplying and fixing of iron stand made out of 40mm x 40mm x 5mm thick angle iron for mounting outdoor unit of the above ac as per manufacturer i/c providing other necessary hardware, painting etc. complete as required., supplying & fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good the damages etc. as per site requirement., supplying and fixing of 25 mm dia isi mark heavy duty pvc pipe with accessories for drain water connection, over and above 3 mtrs length wherever required etc. complete as required., supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required. in kolkata, west bengal,. Reference number 15960320. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!

T18 Ref No:15960320
Tender ID:GEM/2026/B/7705773
Tender Agency:bharat sanchar nigam limited BSNL
City:kolkata
State:west bengal
Tender Related Keywords :split air conditioner, air conditioner unit, electrical cable, connection cable, copper conductor, refrigerant pipe, air conditioner, refrigerant gas, steel enclosure, remote control, copper tubes, cement brick, power supply, copper cable, copper pipe, metal plate, power point, sheet steel, water pipe, drain pipe, cable tray, iron stand, angle iron, split ac, ac units, ms sheet, pvc pipe, ac unit, bracket, bolts
Description :total quantity = 175 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc),oem authorization certificate,oem annual turnover,additional doc 1 (requested in atc),additional doc 2 (requested in atc),additional doc 3 (requested in atc),additional doc 4 (requested in atc),compliance of boq specification and supporting document
Tender Value:Refer Document
Tender EMD:Refer Document
Tender Fee:Refer Document
Published Date:Jun 24, 2026
Due Date:Jul 04, 2026
Tender Opening Date:Jul 04, 2026
T18 Ref No:15960320Tender Value:Refer Document
Tender ID:GEM/2026/B/7705773Tender EMD:Refer Document
Tender Agency:bharat sanchar nigam limited BSNLTender Fee:Refer Document
City:kolkataPublished Date:Jun 24, 2026
State:west bengalDue Date:Jul 04, 2026
Tender Related Keywords :split air conditioner, air conditioner unit, electrical cable, connection cable, copper conductor, refrigerant pipe, air conditioner, refrigerant gas, steel enclosure, remote control, copper tubes, cement brick, power supply, copper cable, copper pipe, metal plate, power point, sheet steel, water pipe, drain pipe, cable tray, iron stand, angle iron, split ac, ac units, ms sheet, pvc pipe, ac unit, bracket, boltsTender Opening Date:Jul 04, 2026
Description :total quantity = 175 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc),oem authorization certificate,oem annual turnover,additional doc 1 (requested in atc),additional doc 2 (requested in atc),additional doc 3 (requested in atc),additional doc 4 (requested in atc),compliance of boq specification and supporting document
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

This Government Tender has been Published  by Bharat sanchar nigam limited BSNL for work related to split air conditioner,air conditioner unit,electrical cable,connection cable,copper conductor,refrigerant pipe,air conditioner,refrigerant gas,steel enclosure,remote control,copper tubes,cement brick,power supply,copper cable,copper pipe,metal plate,power point,sheet steel,water pipe,drain pipe,cable tray,iron stand,angle iron,split ac,ac units,ms sheet,pvc pipe,ac unit,bracket,bolts in Kolkata, West bengal. The Tender work is tender for sac unit , dismantling ac , covering hole , itc of ac , copper pipe , cable , iron structure , ms stand , water pipe , mcb, supply installation testing and commissioning of 10 nos sac for cntx east telephone bhawan kolkata, supply of 1.5 tr inverter type 5 star rated split air conditioner unit having nominal cooling capacity of 4536 kcal per hr , 5275 watts and as per bee star rating minimum iseer of 5.6 with temperature control thermistor , remote control unit , filters , rotary or scroll or swing type compressor , copper tubes for both indoor and outdoor unit , refrigerant gas with topping up of refrigerant if required , transportation of all of the above to various sites and supplying the following upto the length of 3 mtrs etc as reqd. 1. hot and cold refrigerant piping . 2. suitable connecting electrical cable between indoor and outdoor unit . 3 .pvc drain pipe of suitable size . note . 1 . the manufacturers or suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation , which is earlier , thereafter 4 years additional warranty on the compressor and indoor & outdoor units pcb., dismantling of existing split ac unit - indoor and outdoor units along with interconnecting cu pipe and cable, power connection cable etc. and storing at place shown by exch. in charge etc. as reqd., covering the opening in wall by metal plate/cement brick in case of brick wall subsequent to removal of old wac units to avoid any leakage of cool air etc. complete as required., installation, testing and commissioning of 1.5 tr 5 star inverter type split ac unit along with hot and cold refrigerant copper piping, copper conductor flexible connecting electrical cable & pvc drain pipe up to the standard length of 3 mtrs. (as supplied under item 1) including leak testing entire system, gas charging, insulating the refrigerant pipe and making opening in wall and making good the damages, making power supply connections from the power point etc. complete as required., providing and fixing of additional refrigerant copper piping i. e. for hot & cold line of suitable size to match with the pipeline of the new split ac units, over and above 3 mtrs length wherever required along with suitable size rubber foam insulation on surface of the wall including necessary flare nuts, suitably brazing with the existing pipe, clamping, making holes in walls & additional gas charging if required etc. as per site requirement complete as reqd. note - the length of refrigerant pipes supplied with each ac units is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates. only single run will be measured for both i. e. hot gas and cold liquid line refrigerant pipes., supplying and laying 4 core 2.5 sq.mm. pvc insulated and pvc sheathed flexible copper cable along with refrigerant pipe or along with existing conduit or cable tray including binding with plastic tags for extending supply from existing industrial socket to indoor unit etc. as required. make any isi mark . note the length of copper cable supplied with each unit is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates., supplying and fixing of iron stand made out of 40mm x 40mm x 5mm thick angle iron for mounting outdoor unit of the above ac as per manufacturer i/c providing other necessary hardware, painting etc. complete as required., supplying & fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good the damages etc. as per site requirement., supplying and fixing of 25 mm dia isi mark heavy duty pvc pipe with accessories for drain water connection, over and above 3 mtrs length wherever required etc. complete as required., supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required.. Tender18 Provide this type Government Tender Information on daily basis.


This tender invites eligible contractors, suppliers, manufacturers, consultants, Startups, Msmes, traders and service providers to submit bids for the specified project, supply, service, or work requirement.


Before applying, interested bidders should review the tender scope, eligibility criteria, estimated contract value, important dates, technical requirements, reqired docuent list for bidder and bid submission instructions as per provided in the official tender documents. 


This Verified Information Provide By Tender18 in this page so Bidder Can Easiy  Understanding tender  requirements and bidders can prepare a compliant and competitive tender proposal.

To participate in the tender for sac unit , dismantling ac , covering hole , itc of ac , copper pipe , cable , iron structure , ms stand , water pipe , mcb, supply installation testing and commissioning of 10 nos sac for cntx east telephone bhawan kolkata, supply of 1.5 tr inverter type 5 star rated split air conditioner unit having nominal cooling capacity of 4536 kcal per hr , 5275 watts and as per bee star rating minimum iseer of 5.6 with temperature control thermistor , remote control unit , filters , rotary or scroll or swing type compressor , copper tubes for both indoor and outdoor unit , refrigerant gas with topping up of refrigerant if required , transportation of all of the above to various sites and supplying the following upto the length of 3 mtrs etc as reqd. 1. hot and cold refrigerant piping . 2. suitable connecting electrical cable between indoor and outdoor unit . 3 .pvc drain pipe of suitable size . note . 1 . the manufacturers or suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation , which is earlier , thereafter 4 years additional warranty on the compressor and indoor & outdoor units pcb., dismantling of existing split ac unit - indoor and outdoor units along with interconnecting cu pipe and cable, power connection cable etc. and storing at place shown by exch. in charge etc. as reqd., covering the opening in wall by metal plate/cement brick in case of brick wall subsequent to removal of old wac units to avoid any leakage of cool air etc. complete as required., installation, testing and commissioning of 1.5 tr 5 star inverter type split ac unit along with hot and cold refrigerant copper piping, copper conductor flexible connecting electrical cable & pvc drain pipe up to the standard length of 3 mtrs. (as supplied under item 1) including leak testing entire system, gas charging, insulating the refrigerant pipe and making opening in wall and making good the damages, making power supply connections from the power point etc. complete as required., providing and fixing of additional refrigerant copper piping i. e. for hot & cold line of suitable size to match with the pipeline of the new split ac units, over and above 3 mtrs length wherever required along with suitable size rubber foam insulation on surface of the wall including necessary flare nuts, suitably brazing with the existing pipe, clamping, making holes in walls & additional gas charging if required etc. as per site requirement complete as reqd. note - the length of refrigerant pipes supplied with each ac units is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates. only single run will be measured for both i. e. hot gas and cold liquid line refrigerant pipes., supplying and laying 4 core 2.5 sq.mm. pvc insulated and pvc sheathed flexible copper cable along with refrigerant pipe or along with existing conduit or cable tray including binding with plastic tags for extending supply from existing industrial socket to indoor unit etc. as required. make any isi mark . note the length of copper cable supplied with each unit is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates., supplying and fixing of iron stand made out of 40mm x 40mm x 5mm thick angle iron for mounting outdoor unit of the above ac as per manufacturer i/c providing other necessary hardware, painting etc. complete as required., supplying & fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good the damages etc. as per site requirement., supplying and fixing of 25 mm dia isi mark heavy duty pvc pipe with accessories for drain water connection, over and above 3 mtrs length wherever required etc. complete as required., supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required., bidders should first download and review all available tender documents. These documents generally include the Notice Inviting Tender (NIT), Bill of Quantities (BOQ), technical specifications, eligibility criteria, scope of work, and bid submission instructions.


Tender Governemnt Authorities like Bharat sanchar nigam limited BSNL usually publish these documents on their official eProcurement portals, departmental tender portals, the GeM Tender Portal, or other government procurement platforms or on newspapre. Finding and accessing the correct tender documents across multiple portals can sometimes be time-consuming for bidders. 


To make the process easier, Tender18 provides quick access to the available tender documents related to this Kolkata , West bengal tender on a single page. Businesses involved in split air conditioner,air conditioner unit,electrical cable,connection cable,copper conductor,refrigerant pipe,air conditioner,refrigerant gas,steel enclosure,remote control,copper tubes,cement brick,power supply,copper cable,copper pipe,metal plate,power point,sheet steel,water pipe,drain pipe,cable tray,iron stand,angle iron,split ac,ac units,ms sheet,pvc pipe,ac unit,bracket,bolts related products, services, or works can conveniently download the relevant documents and review the tender requirements without spending time searching across different procurement portals.

The tender for sac unit , dismantling ac , covering hole , itc of ac , copper pipe , cable , iron structure , ms stand , water pipe , mcb, supply installation testing and commissioning of 10 nos sac for cntx east telephone bhawan kolkata, supply of 1.5 tr inverter type 5 star rated split air conditioner unit having nominal cooling capacity of 4536 kcal per hr , 5275 watts and as per bee star rating minimum iseer of 5.6 with temperature control thermistor , remote control unit , filters , rotary or scroll or swing type compressor , copper tubes for both indoor and outdoor unit , refrigerant gas with topping up of refrigerant if required , transportation of all of the above to various sites and supplying the following upto the length of 3 mtrs etc as reqd. 1. hot and cold refrigerant piping . 2. suitable connecting electrical cable between indoor and outdoor unit . 3 .pvc drain pipe of suitable size . note . 1 . the manufacturers or suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation , which is earlier , thereafter 4 years additional warranty on the compressor and indoor & outdoor units pcb., dismantling of existing split ac unit - indoor and outdoor units along with interconnecting cu pipe and cable, power connection cable etc. and storing at place shown by exch. in charge etc. as reqd., covering the opening in wall by metal plate/cement brick in case of brick wall subsequent to removal of old wac units to avoid any leakage of cool air etc. complete as required., installation, testing and commissioning of 1.5 tr 5 star inverter type split ac unit along with hot and cold refrigerant copper piping, copper conductor flexible connecting electrical cable & pvc drain pipe up to the standard length of 3 mtrs. (as supplied under item 1) including leak testing entire system, gas charging, insulating the refrigerant pipe and making opening in wall and making good the damages, making power supply connections from the power point etc. complete as required., providing and fixing of additional refrigerant copper piping i. e. for hot & cold line of suitable size to match with the pipeline of the new split ac units, over and above 3 mtrs length wherever required along with suitable size rubber foam insulation on surface of the wall including necessary flare nuts, suitably brazing with the existing pipe, clamping, making holes in walls & additional gas charging if required etc. as per site requirement complete as reqd. note - the length of refrigerant pipes supplied with each ac units is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates. only single run will be measured for both i. e. hot gas and cold liquid line refrigerant pipes., supplying and laying 4 core 2.5 sq.mm. pvc insulated and pvc sheathed flexible copper cable along with refrigerant pipe or along with existing conduit or cable tray including binding with plastic tags for extending supply from existing industrial socket to indoor unit etc. as required. make any isi mark . note the length of copper cable supplied with each unit is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates., supplying and fixing of iron stand made out of 40mm x 40mm x 5mm thick angle iron for mounting outdoor unit of the above ac as per manufacturer i/c providing other necessary hardware, painting etc. complete as required., supplying & fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good the damages etc. as per site requirement., supplying and fixing of 25 mm dia isi mark heavy duty pvc pipe with accessories for drain water connection, over and above 3 mtrs length wherever required etc. complete as required., supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required. from Kolkata, West bengal may be relevant for contractors, suppliers, vendors, manufacturers, consultants, service providers, startups, MSMEs, and other organizations involved in split air conditioner,air conditioner unit,electrical cable,connection cable,copper conductor,refrigerant pipe,air conditioner,refrigerant gas,steel enclosure,remote control,copper tubes,cement brick,power supply,copper cable,copper pipe,metal plate,power point,sheet steel,water pipe,drain pipe,cable tray,iron stand,angle iron,split ac,ac units,ms sheet,pvc pipe,ac unit,bracket,bolts related products, services, or works. However, eligibility to participate depends on the qualification criteria specified by Bharat sanchar nigam limited BSNL in the official tender documents.

Before submitting a bid, interested applicants should carefully review the eligibility conditions, technical requirements, financial criteria, work experience requirements, annual turnover conditions, registrations, certifications, and any other supporting documents required by the tendering authority. The detailed qualification requirements and bidder eligibility criteria are available in the tender notice and related documents provided on this page. 

Ensuring compliance with all eligibility and qualification requirements before bid submission can help bidders avoid disqualification and improve their chances of successful participation in the tender process.

Tende18 provides comprehensive tender bidding services, including a complete tender summary along with a detailed analysis of the Tender Qualification and Eligibility Criteria.

Interested in participating in the tender for sac unit , dismantling ac , covering hole , itc of ac , copper pipe , cable , iron structure , ms stand , water pipe , mcb, supply installation testing and commissioning of 10 nos sac for cntx east telephone bhawan kolkata, supply of 1.5 tr inverter type 5 star rated split air conditioner unit having nominal cooling capacity of 4536 kcal per hr , 5275 watts and as per bee star rating minimum iseer of 5.6 with temperature control thermistor , remote control unit , filters , rotary or scroll or swing type compressor , copper tubes for both indoor and outdoor unit , refrigerant gas with topping up of refrigerant if required , transportation of all of the above to various sites and supplying the following upto the length of 3 mtrs etc as reqd. 1. hot and cold refrigerant piping . 2. suitable connecting electrical cable between indoor and outdoor unit . 3 .pvc drain pipe of suitable size . note . 1 . the manufacturers or suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation , which is earlier , thereafter 4 years additional warranty on the compressor and indoor & outdoor units pcb., dismantling of existing split ac unit - indoor and outdoor units along with interconnecting cu pipe and cable, power connection cable etc. and storing at place shown by exch. in charge etc. as reqd., covering the opening in wall by metal plate/cement brick in case of brick wall subsequent to removal of old wac units to avoid any leakage of cool air etc. complete as required., installation, testing and commissioning of 1.5 tr 5 star inverter type split ac unit along with hot and cold refrigerant copper piping, copper conductor flexible connecting electrical cable & pvc drain pipe up to the standard length of 3 mtrs. (as supplied under item 1) including leak testing entire system, gas charging, insulating the refrigerant pipe and making opening in wall and making good the damages, making power supply connections from the power point etc. complete as required., providing and fixing of additional refrigerant copper piping i. e. for hot & cold line of suitable size to match with the pipeline of the new split ac units, over and above 3 mtrs length wherever required along with suitable size rubber foam insulation on surface of the wall including necessary flare nuts, suitably brazing with the existing pipe, clamping, making holes in walls & additional gas charging if required etc. as per site requirement complete as reqd. note - the length of refrigerant pipes supplied with each ac units is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates. only single run will be measured for both i. e. hot gas and cold liquid line refrigerant pipes., supplying and laying 4 core 2.5 sq.mm. pvc insulated and pvc sheathed flexible copper cable along with refrigerant pipe or along with existing conduit or cable tray including binding with plastic tags for extending supply from existing industrial socket to indoor unit etc. as required. make any isi mark . note the length of copper cable supplied with each unit is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates., supplying and fixing of iron stand made out of 40mm x 40mm x 5mm thick angle iron for mounting outdoor unit of the above ac as per manufacturer i/c providing other necessary hardware, painting etc. complete as required., supplying & fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good the damages etc. as per site requirement., supplying and fixing of 25 mm dia isi mark heavy duty pvc pipe with accessories for drain water connection, over and above 3 mtrs length wherever required etc. complete as required., supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required. issued by Bharat sanchar nigam limited BSNL for split air conditioner,air conditioner unit,electrical cable,connection cable,copper conductor,refrigerant pipe,air conditioner,refrigerant gas,steel enclosure,remote control,copper tubes,cement brick,power supply,copper cable,copper pipe,metal plate,power point,sheet steel,water pipe,drain pipe,cable tray,iron stand,angle iron,split ac,ac units,ms sheet,pvc pipe,ac unit,bracket,bolts related work in Kolkata, West bengal? TENDER18 provides complete assistance to help businesses understand tender requirements, access tender documents, review eligibility criteria, qualification requirements, important dates, and bid submission guidelines associated with this tender.

Our Tender18 Expert Technical team can assist with vendor and GeM registration on the relevant departmental, eProcurement, GeM, or government tender portal, preparation of technical and financial bid documents, compliance with qualification criteria, document verification, and complete online tender submission support. Whether you are a contractor, supplier, manufacturer, consultant, startup, or MSME working in the field of split air conditioner,air conditioner unit,electrical cable,connection cable,copper conductor,refrigerant pipe,air conditioner,refrigerant gas,steel enclosure,remote control,copper tubes,cement brick,power supply,copper cable,copper pipe,metal plate,power point,sheet steel,water pipe,drain pipe,cable tray,iron stand,angle iron,split ac,ac units,ms sheet,pvc pipe,ac unit,bracket,bolts, Tender18 can help simplify the tender participation process and support you throughout every stage of bidding for this tender. so that tender18 is one the top leading tender consultant in Inda.

1.

Whom should I contact if I have further queries about the Tender scope?

You can fill out the integrated inquiry form below on this detail page to share your company profile. Our consultancy desk will review your query regarding split air conditioner,air conditioner unit,electrical cable,connection cable,copper conductor,refrigerant pipe,air conditioner,refrigerant gas,steel enclosure,remote control,copper tubes,cement brick,power supply,copper cable,copper pipe,metal plate,power point,sheet steel,water pipe,drain pipe,cable tray,iron stand,angle iron,split ac,ac units,ms sheet,pvc pipe,ac unit,bracket,bolts parameters and guide you on how to coordinate efficiently with the procurement team of Bharat sanchar nigam limited BSNL

2.

How can Tender18 assist my business in winning this government contract?

Tender18 provides end-to-end professional bidding support and documentation advisory for tender for sac unit , dismantling ac , covering hole , itc of ac , copper pipe , cable , iron structure , ms stand , water pipe , mcb, supply installation testing and commissioning of 10 nos sac for cntx east telephone bhawan kolkata, supply of 1.5 tr inverter type 5 star rated split air conditioner unit having nominal cooling capacity of 4536 kcal per hr , 5275 watts and as per bee star rating minimum iseer of 5.6 with temperature control thermistor , remote control unit , filters , rotary or scroll or swing type compressor , copper tubes for both indoor and outdoor unit , refrigerant gas with topping up of refrigerant if required , transportation of all of the above to various sites and supplying the following upto the length of 3 mtrs etc as reqd. 1. hot and cold refrigerant piping . 2. suitable connecting electrical cable between indoor and outdoor unit . 3 .pvc drain pipe of suitable size . note . 1 . the manufacturers or suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation , which is earlier , thereafter 4 years additional warranty on the compressor and indoor & outdoor units pcb., dismantling of existing split ac unit - indoor and outdoor units along with interconnecting cu pipe and cable, power connection cable etc. and storing at place shown by exch. in charge etc. as reqd., covering the opening in wall by metal plate/cement brick in case of brick wall subsequent to removal of old wac units to avoid any leakage of cool air etc. complete as required., installation, testing and commissioning of 1.5 tr 5 star inverter type split ac unit along with hot and cold refrigerant copper piping, copper conductor flexible connecting electrical cable & pvc drain pipe up to the standard length of 3 mtrs. (as supplied under item 1) including leak testing entire system, gas charging, insulating the refrigerant pipe and making opening in wall and making good the damages, making power supply connections from the power point etc. complete as required., providing and fixing of additional refrigerant copper piping i. e. for hot & cold line of suitable size to match with the pipeline of the new split ac units, over and above 3 mtrs length wherever required along with suitable size rubber foam insulation on surface of the wall including necessary flare nuts, suitably brazing with the existing pipe, clamping, making holes in walls & additional gas charging if required etc. as per site requirement complete as reqd. note - the length of refrigerant pipes supplied with each ac units is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates. only single run will be measured for both i. e. hot gas and cold liquid line refrigerant pipes., supplying and laying 4 core 2.5 sq.mm. pvc insulated and pvc sheathed flexible copper cable along with refrigerant pipe or along with existing conduit or cable tray including binding with plastic tags for extending supply from existing industrial socket to indoor unit etc. as required. make any isi mark . note the length of copper cable supplied with each unit is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates., supplying and fixing of iron stand made out of 40mm x 40mm x 5mm thick angle iron for mounting outdoor unit of the above ac as per manufacturer i/c providing other necessary hardware, painting etc. complete as required., supplying & fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good the damages etc. as per site requirement., supplying and fixing of 25 mm dia isi mark heavy duty pvc pipe with accessories for drain water connection, over and above 3 mtrs length wherever required etc. complete as required., supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required. . Our senior analysts help you decode the complete project guidelines, manage accurate costing sheets, and complete error-free submissions on the official platform used by Bharat sanchar nigam limited BSNL.

3.

What are the main reasons for a technical tender rejection?

Most online bids face rejection during the initial evaluation round due to avoidable errors like uploading blurred document scans, submitting expired DSCs, or missing critical experience papers required for tender for sac unit , dismantling ac , covering hole , itc of ac , copper pipe , cable , iron structure , ms stand , water pipe , mcb, supply installation testing and commissioning of 10 nos sac for cntx east telephone bhawan kolkata, supply of 1.5 tr inverter type 5 star rated split air conditioner unit having nominal cooling capacity of 4536 kcal per hr , 5275 watts and as per bee star rating minimum iseer of 5.6 with temperature control thermistor , remote control unit , filters , rotary or scroll or swing type compressor , copper tubes for both indoor and outdoor unit , refrigerant gas with topping up of refrigerant if required , transportation of all of the above to various sites and supplying the following upto the length of 3 mtrs etc as reqd. 1. hot and cold refrigerant piping . 2. suitable connecting electrical cable between indoor and outdoor unit . 3 .pvc drain pipe of suitable size . note . 1 . the manufacturers or suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation , which is earlier , thereafter 4 years additional warranty on the compressor and indoor & outdoor units pcb., dismantling of existing split ac unit - indoor and outdoor units along with interconnecting cu pipe and cable, power connection cable etc. and storing at place shown by exch. in charge etc. as reqd., covering the opening in wall by metal plate/cement brick in case of brick wall subsequent to removal of old wac units to avoid any leakage of cool air etc. complete as required., installation, testing and commissioning of 1.5 tr 5 star inverter type split ac unit along with hot and cold refrigerant copper piping, copper conductor flexible connecting electrical cable & pvc drain pipe up to the standard length of 3 mtrs. (as supplied under item 1) including leak testing entire system, gas charging, insulating the refrigerant pipe and making opening in wall and making good the damages, making power supply connections from the power point etc. complete as required., providing and fixing of additional refrigerant copper piping i. e. for hot & cold line of suitable size to match with the pipeline of the new split ac units, over and above 3 mtrs length wherever required along with suitable size rubber foam insulation on surface of the wall including necessary flare nuts, suitably brazing with the existing pipe, clamping, making holes in walls & additional gas charging if required etc. as per site requirement complete as reqd. note - the length of refrigerant pipes supplied with each ac units is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates. only single run will be measured for both i. e. hot gas and cold liquid line refrigerant pipes., supplying and laying 4 core 2.5 sq.mm. pvc insulated and pvc sheathed flexible copper cable along with refrigerant pipe or along with existing conduit or cable tray including binding with plastic tags for extending supply from existing industrial socket to indoor unit etc. as required. make any isi mark . note the length of copper cable supplied with each unit is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates., supplying and fixing of iron stand made out of 40mm x 40mm x 5mm thick angle iron for mounting outdoor unit of the above ac as per manufacturer i/c providing other necessary hardware, painting etc. complete as required., supplying & fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good the damages etc. as per site requirement., supplying and fixing of 25 mm dia isi mark heavy duty pvc pipe with accessories for drain water connection, over and above 3 mtrs length wherever required etc. complete as required., supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required. in West bengal.

4.

Can contractors located outside the local region participate in this bid?

Eligibility for outstation bidders depends entirely on the terms set inside the document for tender for sac unit , dismantling ac , covering hole , itc of ac , copper pipe , cable , iron structure , ms stand , water pipe , mcb, supply installation testing and commissioning of 10 nos sac for cntx east telephone bhawan kolkata, supply of 1.5 tr inverter type 5 star rated split air conditioner unit having nominal cooling capacity of 4536 kcal per hr , 5275 watts and as per bee star rating minimum iseer of 5.6 with temperature control thermistor , remote control unit , filters , rotary or scroll or swing type compressor , copper tubes for both indoor and outdoor unit , refrigerant gas with topping up of refrigerant if required , transportation of all of the above to various sites and supplying the following upto the length of 3 mtrs etc as reqd. 1. hot and cold refrigerant piping . 2. suitable connecting electrical cable between indoor and outdoor unit . 3 .pvc drain pipe of suitable size . note . 1 . the manufacturers or suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation , which is earlier , thereafter 4 years additional warranty on the compressor and indoor & outdoor units pcb., dismantling of existing split ac unit - indoor and outdoor units along with interconnecting cu pipe and cable, power connection cable etc. and storing at place shown by exch. in charge etc. as reqd., covering the opening in wall by metal plate/cement brick in case of brick wall subsequent to removal of old wac units to avoid any leakage of cool air etc. complete as required., installation, testing and commissioning of 1.5 tr 5 star inverter type split ac unit along with hot and cold refrigerant copper piping, copper conductor flexible connecting electrical cable & pvc drain pipe up to the standard length of 3 mtrs. (as supplied under item 1) including leak testing entire system, gas charging, insulating the refrigerant pipe and making opening in wall and making good the damages, making power supply connections from the power point etc. complete as required., providing and fixing of additional refrigerant copper piping i. e. for hot & cold line of suitable size to match with the pipeline of the new split ac units, over and above 3 mtrs length wherever required along with suitable size rubber foam insulation on surface of the wall including necessary flare nuts, suitably brazing with the existing pipe, clamping, making holes in walls & additional gas charging if required etc. as per site requirement complete as reqd. note - the length of refrigerant pipes supplied with each ac units is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates. only single run will be measured for both i. e. hot gas and cold liquid line refrigerant pipes., supplying and laying 4 core 2.5 sq.mm. pvc insulated and pvc sheathed flexible copper cable along with refrigerant pipe or along with existing conduit or cable tray including binding with plastic tags for extending supply from existing industrial socket to indoor unit etc. as required. make any isi mark . note the length of copper cable supplied with each unit is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates., supplying and fixing of iron stand made out of 40mm x 40mm x 5mm thick angle iron for mounting outdoor unit of the above ac as per manufacturer i/c providing other necessary hardware, painting etc. complete as required., supplying & fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good the damages etc. as per site requirement., supplying and fixing of 25 mm dia isi mark heavy duty pvc pipe with accessories for drain water connection, over and above 3 mtrs length wherever required etc. complete as required., supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required.. While many public sector projects allow national competitive bidding, certain localized works require local offices or specific registration metrics in Kolkata.

5.

Do I need an active GeM Portal registration to apply for this work?

If this procurement is routed through the central marketplace, an active GeM Seller ID is mandatory to supply split air conditioner,air conditioner unit,electrical cable,connection cable,copper conductor,refrigerant pipe,air conditioner,refrigerant gas,steel enclosure,remote control,copper tubes,cement brick,power supply,copper cable,copper pipe,metal plate,power point,sheet steel,water pipe,drain pipe,cable tray,iron stand,angle iron,split ac,ac units,ms sheet,pvc pipe,ac unit,bracket,bolts items. Tender18 offers complete assistance for brand cataloging, profile creation, and vendor assessment required officially by Bharat sanchar nigam limited BSNL

6.

What are the primary legal documents required to submit a valid bid?

To register an eligible bid for these split air conditioner,air conditioner unit,electrical cable,connection cable,copper conductor,refrigerant pipe,air conditioner,refrigerant gas,steel enclosure,remote control,copper tubes,cement brick,power supply,copper cable,copper pipe,metal plate,power point,sheet steel,water pipe,drain pipe,cable tray,iron stand,angle iron,split ac,ac units,ms sheet,pvc pipe,ac unit,bracket,bolts contracts, companies must prepare their core compliance documents. Vendors operating across West bengal must ensure they possess a valid GST registration, permanent account number (PAN), and active Class-3 Digital Signature Certificates.

7.

What products or services are required for this active work?

This public procurement cycle is specifically looking for qualified vendors and suppliers who can provide high-quality split air conditioner,air conditioner unit,electrical cable,connection cable,copper conductor,refrigerant pipe,air conditioner,refrigerant gas,steel enclosure,remote control,copper tubes,cement brick,power supply,copper cable,copper pipe,metal plate,power point,sheet steel,water pipe,drain pipe,cable tray,iron stand,angle iron,split ac,ac units,ms sheet,pvc pipe,ac unit,bracket,bolts solutions. The operational execution, delivery, and deployment of these materials must be managed locally within the Kolkata region.

8.

Where can I review the estimated cost or budget details for this Tender?

The estimated project cost and budget thresholds can be reviewed directly inside the tender document. Bidders can analyze these qualification files to check if their firm meets the financial capability criteria specified for tender for sac unit , dismantling ac , covering hole , itc of ac , copper pipe , cable , iron structure , ms stand , water pipe , mcb, supply installation testing and commissioning of 10 nos sac for cntx east telephone bhawan kolkata, supply of 1.5 tr inverter type 5 star rated split air conditioner unit having nominal cooling capacity of 4536 kcal per hr , 5275 watts and as per bee star rating minimum iseer of 5.6 with temperature control thermistor , remote control unit , filters , rotary or scroll or swing type compressor , copper tubes for both indoor and outdoor unit , refrigerant gas with topping up of refrigerant if required , transportation of all of the above to various sites and supplying the following upto the length of 3 mtrs etc as reqd. 1. hot and cold refrigerant piping . 2. suitable connecting electrical cable between indoor and outdoor unit . 3 .pvc drain pipe of suitable size . note . 1 . the manufacturers or suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation , which is earlier , thereafter 4 years additional warranty on the compressor and indoor & outdoor units pcb., dismantling of existing split ac unit - indoor and outdoor units along with interconnecting cu pipe and cable, power connection cable etc. and storing at place shown by exch. in charge etc. as reqd., covering the opening in wall by metal plate/cement brick in case of brick wall subsequent to removal of old wac units to avoid any leakage of cool air etc. complete as required., installation, testing and commissioning of 1.5 tr 5 star inverter type split ac unit along with hot and cold refrigerant copper piping, copper conductor flexible connecting electrical cable & pvc drain pipe up to the standard length of 3 mtrs. (as supplied under item 1) including leak testing entire system, gas charging, insulating the refrigerant pipe and making opening in wall and making good the damages, making power supply connections from the power point etc. complete as required., providing and fixing of additional refrigerant copper piping i. e. for hot & cold line of suitable size to match with the pipeline of the new split ac units, over and above 3 mtrs length wherever required along with suitable size rubber foam insulation on surface of the wall including necessary flare nuts, suitably brazing with the existing pipe, clamping, making holes in walls & additional gas charging if required etc. as per site requirement complete as reqd. note - the length of refrigerant pipes supplied with each ac units is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates. only single run will be measured for both i. e. hot gas and cold liquid line refrigerant pipes., supplying and laying 4 core 2.5 sq.mm. pvc insulated and pvc sheathed flexible copper cable along with refrigerant pipe or along with existing conduit or cable tray including binding with plastic tags for extending supply from existing industrial socket to indoor unit etc. as required. make any isi mark . note the length of copper cable supplied with each unit is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates., supplying and fixing of iron stand made out of 40mm x 40mm x 5mm thick angle iron for mounting outdoor unit of the above ac as per manufacturer i/c providing other necessary hardware, painting etc. complete as required., supplying & fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good the damages etc. as per site requirement., supplying and fixing of 25 mm dia isi mark heavy duty pvc pipe with accessories for drain water connection, over and above 3 mtrs length wherever required etc. complete as required., supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required. by Bharat sanchar nigam limited BSNL

9.

How can I download the official BOQ file for this opportunity?

You can download the commercial Bill of Quantities (BOQ) spreadsheet directly using the secure link provided on this page. The BOQ file contains the item descriptions and rate filling forms officially validated for tender for sac unit , dismantling ac , covering hole , itc of ac , copper pipe , cable , iron structure , ms stand , water pipe , mcb, supply installation testing and commissioning of 10 nos sac for cntx east telephone bhawan kolkata, supply of 1.5 tr inverter type 5 star rated split air conditioner unit having nominal cooling capacity of 4536 kcal per hr , 5275 watts and as per bee star rating minimum iseer of 5.6 with temperature control thermistor , remote control unit , filters , rotary or scroll or swing type compressor , copper tubes for both indoor and outdoor unit , refrigerant gas with topping up of refrigerant if required , transportation of all of the above to various sites and supplying the following upto the length of 3 mtrs etc as reqd. 1. hot and cold refrigerant piping . 2. suitable connecting electrical cable between indoor and outdoor unit . 3 .pvc drain pipe of suitable size . note . 1 . the manufacturers or suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation , which is earlier , thereafter 4 years additional warranty on the compressor and indoor & outdoor units pcb., dismantling of existing split ac unit - indoor and outdoor units along with interconnecting cu pipe and cable, power connection cable etc. and storing at place shown by exch. in charge etc. as reqd., covering the opening in wall by metal plate/cement brick in case of brick wall subsequent to removal of old wac units to avoid any leakage of cool air etc. complete as required., installation, testing and commissioning of 1.5 tr 5 star inverter type split ac unit along with hot and cold refrigerant copper piping, copper conductor flexible connecting electrical cable & pvc drain pipe up to the standard length of 3 mtrs. (as supplied under item 1) including leak testing entire system, gas charging, insulating the refrigerant pipe and making opening in wall and making good the damages, making power supply connections from the power point etc. complete as required., providing and fixing of additional refrigerant copper piping i. e. for hot & cold line of suitable size to match with the pipeline of the new split ac units, over and above 3 mtrs length wherever required along with suitable size rubber foam insulation on surface of the wall including necessary flare nuts, suitably brazing with the existing pipe, clamping, making holes in walls & additional gas charging if required etc. as per site requirement complete as reqd. note - the length of refrigerant pipes supplied with each ac units is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates. only single run will be measured for both i. e. hot gas and cold liquid line refrigerant pipes., supplying and laying 4 core 2.5 sq.mm. pvc insulated and pvc sheathed flexible copper cable along with refrigerant pipe or along with existing conduit or cable tray including binding with plastic tags for extending supply from existing industrial socket to indoor unit etc. as required. make any isi mark . note the length of copper cable supplied with each unit is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates., supplying and fixing of iron stand made out of 40mm x 40mm x 5mm thick angle iron for mounting outdoor unit of the above ac as per manufacturer i/c providing other necessary hardware, painting etc. complete as required., supplying & fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good the damages etc. as per site requirement., supplying and fixing of 25 mm dia isi mark heavy duty pvc pipe with accessories for drain water connection, over and above 3 mtrs length wherever required etc. complete as required., supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required. within the West bengal jurisdiction

10.

How can I find the submission closing date for this contract?

The official timeline and deadline details for tender for sac unit , dismantling ac , covering hole , itc of ac , copper pipe , cable , iron structure , ms stand , water pipe , mcb, supply installation testing and commissioning of 10 nos sac for cntx east telephone bhawan kolkata, supply of 1.5 tr inverter type 5 star rated split air conditioner unit having nominal cooling capacity of 4536 kcal per hr , 5275 watts and as per bee star rating minimum iseer of 5.6 with temperature control thermistor , remote control unit , filters , rotary or scroll or swing type compressor , copper tubes for both indoor and outdoor unit , refrigerant gas with topping up of refrigerant if required , transportation of all of the above to various sites and supplying the following upto the length of 3 mtrs etc as reqd. 1. hot and cold refrigerant piping . 2. suitable connecting electrical cable between indoor and outdoor unit . 3 .pvc drain pipe of suitable size . note . 1 . the manufacturers or suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation , which is earlier , thereafter 4 years additional warranty on the compressor and indoor & outdoor units pcb., dismantling of existing split ac unit - indoor and outdoor units along with interconnecting cu pipe and cable, power connection cable etc. and storing at place shown by exch. in charge etc. as reqd., covering the opening in wall by metal plate/cement brick in case of brick wall subsequent to removal of old wac units to avoid any leakage of cool air etc. complete as required., installation, testing and commissioning of 1.5 tr 5 star inverter type split ac unit along with hot and cold refrigerant copper piping, copper conductor flexible connecting electrical cable & pvc drain pipe up to the standard length of 3 mtrs. (as supplied under item 1) including leak testing entire system, gas charging, insulating the refrigerant pipe and making opening in wall and making good the damages, making power supply connections from the power point etc. complete as required., providing and fixing of additional refrigerant copper piping i. e. for hot & cold line of suitable size to match with the pipeline of the new split ac units, over and above 3 mtrs length wherever required along with suitable size rubber foam insulation on surface of the wall including necessary flare nuts, suitably brazing with the existing pipe, clamping, making holes in walls & additional gas charging if required etc. as per site requirement complete as reqd. note - the length of refrigerant pipes supplied with each ac units is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates. only single run will be measured for both i. e. hot gas and cold liquid line refrigerant pipes., supplying and laying 4 core 2.5 sq.mm. pvc insulated and pvc sheathed flexible copper cable along with refrigerant pipe or along with existing conduit or cable tray including binding with plastic tags for extending supply from existing industrial socket to indoor unit etc. as required. make any isi mark . note the length of copper cable supplied with each unit is 3 mtrs. extra length shall be paid extra for which firm shall quote their unit rates., supplying and fixing of iron stand made out of 40mm x 40mm x 5mm thick angle iron for mounting outdoor unit of the above ac as per manufacturer i/c providing other necessary hardware, painting etc. complete as required., supplying & fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good the damages etc. as per site requirement., supplying and fixing of 25 mm dia isi mark heavy duty pvc pipe with accessories for drain water connection, over and above 3 mtrs length wherever required etc. complete as required., supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required. are available inside the detailed notification files. Bidders planning to target this contract in Kolkata should check the official portal schedule early to complete their online technical and financial submission well before the closing hours.

Tender Inquiry