The corrigendum tender for supply of 11 kv line material , supply of lt line material , safe carriage of 11 kv line material , safe carriage of 8.5 m pcc pole , safe carriage of 11 m stp , erection of 8.5 m pcc single support , erection of 11 m stp single support , erection of 8.5 m pcc double pole , erection of 11 m stp section double pole , dismentalling old weseal conductor , laying acsr weseal conductor , erection of stone pad , erection of barbed wire , erection of f bracket , erection of danger board , erection of pg clamp , erection of allunimum paint , erection of red oxide paint , erection of holding clamp , laying of gi wire 8 swg , laying of gi wire 10 swg , erection of earthing complete , erection of stay set complete , dismentalling of st pole etc , safe carriage of dismantilled material , safe carriage of dismantilled st pole etc , safe carriage of lt line material , safe carriage of lt ab cable , dismentalling of lt ab cable , erection of lt cable , safe carriage of dismantilled lt ab cable, shifting of 11 kv and lt lines and other electrical equipment, stone pad 300x300x75 mm, barbed wire, danger board with clamp, t off channel 125x65x6x1300 mm, clamp for t off channel, top channel 125x65x6x2240 mm, ms dropper channel 100x50x6x2028 mm, f clamp with nut and bolts, pg clamp for weseal to weseal, gi wire 10 swg, holding clamp, red oxide paints, allunimum paints, guarding angle 65x65x6x1600 mm, guarding clamp, nut and bolts with washer, clamp with nut and bolts, suspension clamp, dead end clamp, lt ab cable 1x25+1x16 sq. mm, safe carriage of line material from store center etah / nearest 33/11 kv s/s to direct pit site in distance range 0 to 60 km. including loading and unloading at both side., safe carriage of 8.5 mtr long pcc pole from store center etah / nearest 33/11 kv s/s to direct pit site in distance range 0 to 60 km. including loading and unloading at both side., safe carriage of 11 mtr long st pole from store center etah / nearest 33/11 kv s/s to direct pit site in distance range 0 to 60 km. including loading and unloading at both side., erection of 8.5 mtr long pcc pole as single support including fixing of ht/lt accessories etc complete, pole should be gruted properly as per dvvnl/respo norms., erection of 11 mtr st pole as single support including fixing of all ht/lt accessories etc. complet, pole should be grouted properly as per dvvnl/respo norms., erection of 8.5 mtr pcc as double pole/section pole including fixing of all ht/lt accessories etc. complete pole should be grouted properly as per dvvnl/respo norms., erection of 11 mtr long st pole as section pole/ double pole including fixing of all ht/lt accessories etc. complete with tpmo, pole should be grouted properly as per dvvnl/respo norms., dismentalling of old acsr weseal conductor stacking of proper place., laying, sagging stringing, binding, jumpering & fixing of all accessories etc of acsr weseal conductor on the newly/old erected pole as per respo manual and as per direction of supervising engineer. it includes the cost of labour, t & p, carrier etc required for proper completion of work., fixing of stone pad 300x300x75 mm, fixing of barbed wire, fixing of f clamp with nut & bolts, fixing of danger board with clamp, pg clamp, fixing of alluminium paint, fixing of red oxide paint, fixing of holding clamp, laying of gi wire 8 swg, laying of gi wire 10 swg, erection of earthing complete, fixing of stay set complete including the work of nozzling etc., dismentalling of st pole/guarter & rail pole stacking of proper place., safe carriage of dismantilled material (acsr weseal conductor, cross arm, clamp, f clamp, top channel & other accessories etc.) from the pit side to the store distance 0 to 60 km. with loading & unloading at both ends and proper stacking in store., safe carriage of dismantiled st pole/gattere & rail pole from the pit side to store in distance 0 to 60 km with loading and unloading at both ends proper stacking in store., safe carriage of lt ab cable 3x50+1x35+1x16 sq. mm from store center etah / nearest 33/11 kv s/s to direct pit site in distance range 0 to 60 km. including loading and unloading at both side., safe carriage of lt ab cable 3x120+1x95+1x16 sq. mm from store center etah / nearest 33/11 kv s/s to direct pit site in distance range 0 to 60 km. including loading and unloading at both side., dismentalling of lt ab cable 3x50+1x35+1x16 sq. mm stacking of proper place., dismentalling of lt ab cable 3x120+1x95+1x16 sq. mm stacking of proper place., dismentalling of lt ab cable 1x125+1x16 sq. mm stacking of proper place., laying, sagging stringing, binding, jumpering & fixing of all accessories etc of lt ab cable 3x50+1x35+1x16 sq. mm on the newly/old erected pole as per respo manual and as per direction of supervising engineer. it includes the cost of labour, t & p, carrier etc required for proper completion of work., laying, sagging stringing, binding, jumpering & fixing of all accessories etc of lt ab cable 3x120+1x95+1x16 sq. mm on the newly/old erected pole as per respo manual and as per direction of supervising engineer. it includes the cost of labour, t & p, carrier etc required for proper completion of work., laying, sagging stringing, binding, jumpering & fixing of all accessories etc of lt ab cable 1x25+1x16 sq. mm on the newly/old erected pole as per respo manual and as per direction of supervising engineer. it includes the cost of labour, t & p, carrier etc required for proper completion of work., fixing of earthing complete, safe carriage of dismantilled material (lt ab cable) from the pit side to the store distance 0 to 60 km. with loading & unloading at both ends and proper stacking in store. from Etah, Uttar pradesh may be relevant for contractors, suppliers, vendors, manufacturers, consultants, service providers, startups, MSMEs, and other organizations involved in unloading,stacking,bracket,washer,labour,clamp,bolts,angle,wire,nut related products, services, or works. However, eligibility to participate depends on the qualification criteria specified by Uttar pradesh power corporation limited UPPCL in the official tender documents.
Before submitting a bid, interested applicants should carefully review the eligibility conditions, technical requirements, financial criteria, work experience requirements, annual turnover conditions, registrations, certifications, and any other supporting documents required by the tendering authority. The detailed qualification requirements and bidder eligibility criteria are available in the tender notice and related documents provided on this page.
Ensuring compliance with all eligibility and qualification requirements before bid submission can help bidders avoid disqualification and improve their chances of successful participation in the tender process.
Tende18 provides comprehensive tender bidding services, including a complete tender summary along with a detailed analysis of the Tender Qualification and Eligibility Criteria.