The tender for safe carriage of 8.5 m pcc pole , safe carriage of 11 and 13 m stp , safe carriage of 9 m stp , safe carriage of line material , opening binding dog raccon rabbit conductor , opening binding weseal conductor gi wire , opening binding of ab cable , erection of 8.5 m pcc as single support , erection of 9 m stp as single support , erection of 11 and 13 m stp as single support , erecton of 8.5 m pcc double section pole , erecton of 9 m stp double section pole , laying stringing dog raccon rabbit , laying stringing acsr weseal gi wire , laying stringing ab cable , straightening of tilted pcc stp single support , straightening of tilted double pole , opening of ht lt 25 kva 63 kva tf connection , opening of ht lt 100 kva tf connection , dismantelling of old material , re sagging of ht lt conductor , re sagging of ab cable , replacement of brocken damaged accessories , retightening of stay rod , providing and fixing of stay rod , earthing of pcc rs joist stp , carriage of old material , mounting of 25 kva 63 kva tf , mounting of 100 kva tf , chopping of tree branches , repairing resagging new guarding ht line, replacement of conductor poles and associated work in daviya aapda edsd iv, safe carriage of 8.5 mtr. long pcc pole from store center etah/nearest 33/11 kv s/s to direct pit site in distance range 0 to 60 km. including loading & unloading at both ends., safe carriage of 11/13 mtr stp from store center etah/nearest 33/11 kv s/s to direct pit site in distance range 0 to 60 km. including loading & unloading at both ends., safe carriage of 9 mtr stp from store center etah/nearest 33/11 kv s/s to direct pit site in distance range 0 to 60 km. including loading & unloading at both ends., safe carriage of line material from store center etah/nearest substation to pit site in distance range 0 to 60 km. including loading & unloading at both ends., opening of binding & removal of dog/ raccoon/ rabbit conductor with 33 kv/ht/lt line from broken pcc poles/rails/ stp and stacking at safer place., opening of binding & removal of acsr weasel conductor/ gi wire with 33 kv/ht/lt line from broken pcc poles/rails/ stp and stacking at safer place., opening of binding & removal of abc 3x95+1x35+1x16/3x50mm with 33 kv/ht/lt line from broken pcc poles/rails/ stp and stacking at safer place., opening of binding & removal of abc 3x120+1x70+1x16 with 33 kv/ht/lt line from broken pcc poles/rails/ stp and stacking at safer place., erection of 8.5 mtr. long pcc poles as single support including fixing of all ht/lt accessories etc. complete.pole should be grouted properly as per dvvnl/respo normes, erection of 9 mtr. stp as single support including fixing of all ht/lt accessories etc. complete.pole should be grouted properly as per dvvnl/respo normes, erection of 11/13 mtr.stp as single support including fixing of all ht/lt accessories etc. complete.pole should be grouted properly as per dvvnl/respo normes, erection of 8.5 mtr. long pcc poles as double pole/ section pole including drilling,cutting etc. and fixing of all accessories etc. complete., erection of 11mtr. stp as double pole/ section pole including drilling,cutting etc. and fixing of all accessories etc. complete., laying stringing & sagging of 3 phase 3 wire 33/ht/lt line with dog/ raccoon/ rabbit conductor including binding & nozzling., laying stringing & sagging of 3 phase 3 wire 33/ht/lt line with acsr weasel conductor/ gi wire including binding & nozzling., laying stringing & sagging of 3 phase 3 wire 33/ht/lt line with abc 3x95 mm/3x50 mm. including binding & nozzling., laying stringing & sagging of 3 phase 3 wire 33/ht/lt line with abc 3x120+1x70+1x16 including binding & nozzling., straightening of tilted pcc poles/stp/rail single support of ht/lt line after opening of nuzzling, digging of pit applying anti direction force for making of proper alignment of line., straightening of tilted d/p after opening of connection applying anti direction force, digging of dug for proper alignment of line including reconnection etc. complete., opening of ht/lt connections & lowering of 25/63 kva t/f from d/p/plinth and shifting up to in safer place., opening of ht/lt connections & lowering of 100 kva t/f from d/p/plinth and shifting up to in safer place., dismanteling of old/damage stp/rs joist of ht/lt line and carriage to store centre etah, re-sagging of dog/ raccoon/ rabbit conductor loose 33/ht/lt conductor after opening, binding, nozzling etc., re-sagging of acsr weasel conductor/ gi wire loose 33/ht/lt conductor after opening, binding, nozzling etc., re-sagging of abc 3x120+1x70+1x16 loose 33/ht/lt cable after opening, binding, nozzling etc., re-sagging of abc 3x50/3x95 loose 33/ht/lt cable after opening, binding, nozzling etc., replacement of 11 kv cross arms v type broken/damaged/missing accessories by new accessories including opening of the same and refixing., replacement of 11 kv pin insulator broken/damaged/missing accessories by new accessories including opening of the same and refixing., replacement of 11 kv pin with nut broken/damaged/missing accessories by new accessories including opening of the same and refixing., replacement of 11 kv disc insulator broken/damaged/missing accessories by new accessories including opening of the same and refixing., replacement of cross arms holding clamps broken/damaged/missing accessories by new accessories including opening of the same and refixing., replacement of f clamps broken/damaged/missing accessories by new accessories including opening of the same and refixing., replacement of lt shackle insulator broken/damaged/missing accessories by new accessories including opening of the same and refixing., replacement of 33 kv cross arm broken/damaged/missing accessories by new accessories including opening of the same and refixing., replacement of 33 kv pin with nut broken/damaged/missing accessories by new accessories including opening of the same and refixing., replacement of 33 kv pin insulator broken/damaged/missing accessories by new accessories including opening of the same and refixing., retightening of stay rod. etc. complete., providing fixing of stay rod with nuzzling etc. complete., earthing of pcc/rs joist/stp as per respo norms., carriage of old material from pit site to je store/store center, etah in distance range 0 to 10 km including loading & unloading and proper stacking., mounting of 25/63 kva t/f on double pole/plinth including making of the connection etc complete., mounting of 100 kva t/f on double pole/plinth including making of the connection etc complete., chopping of tree branches, repairing/ resagging / new guarding of ht lines with gi wire as per respo norms from Etah, Uttar pradesh may be relevant for contractors, suppliers, vendors, manufacturers, consultants, service providers, startups, MSMEs, and other organizations involved in unloading,stacking,drilling,clamps,wire,nut related products, services, or works. However, eligibility to participate depends on the qualification criteria specified by Uttar pradesh power corporation limited UPPCL in the official tender documents.
Before submitting a bid, interested applicants should carefully review the eligibility conditions, technical requirements, financial criteria, work experience requirements, annual turnover conditions, registrations, certifications, and any other supporting documents required by the tendering authority. The detailed qualification requirements and bidder eligibility criteria are available in the tender notice and related documents provided on this page.
Ensuring compliance with all eligibility and qualification requirements before bid submission can help bidders avoid disqualification and improve their chances of successful participation in the tender process.
Tende18 provides comprehensive tender bidding services, including a complete tender summary along with a detailed analysis of the Tender Qualification and Eligibility Criteria.