tender for supply installation testing and commissioning of analgue addressable 1 loop control panel all as specified in srl no 1 of appendix a , supply installation testing and commissioning of analogue addressable multi sensor with baseall as specified in srl no 1 of appendix a , sitcofanalogue addressable manual call point all as specified in srl no 3 of appendix a , sitcof intelligent loop powered wall sounder beacon with base all as specified in srl no 4 of appendix a , s and l 2 core 1 point 5 sqmm fire alarm armoured cable all as specified in srl no 5 of appendix a , supply installation testing and commissioning of industrial ductable super cooler all as specified in srl no 6 of appendix a , m and l for fabrication installation balancing of site fabricated gss sheet metal rectangular ducting all as specified in srl no 7of appendix a , m and l for xlpe insulation high quality xlpe aluminum with form 9mm insulation for duct all as specified in srl no 8of appendix a , s and f of imported air grills with auto swing all as specified in srl no 9 of appendix a , s and f of lack phase voltage power fluctuation all as specified in srl no 10 of appendix a , sfc of fire retardant anti vibration canvas connector all as specified in srl no 11 of appendix a , m and l for iron frame stand for mounting of machine and fixing on location all as specified in srl no 12 of appendix a , m and l for sub main wiring with 1 core 4 sqmm pvc insulated copper conductor all as specified in srl no 13 of appendix a , s and f 6 core 1 point 5 sqmm copper conductor cable all as specified in srl no 14 of appendix a , supply installation of water storage tank cap 1000 ltr 3 layer all as specified in srl no 15 of appendix a , s and f including all fittings gi pipe medium grade of 20 mm dia all as specified in srl no 16 of appendix a , s and f including all fittings gi pipe medium grade of 15mm dia all as specified in srl no 17 of appendix a , s and fixing gun metal gate or stop valves with iron wheel head all as specified in srl no 18 of appendix a , s and f ball valves ptmt 20mm all as specified in srl no 19 of appendix a , s and f pvc connection pipe of 15 mm bore all as specified in srl no 20 of appendix a , s and f pvc flexible drain pipe of size 30 all as specified in srl no 21 of appendix a , cutting existing road hard standing with width not exceeding 750 mm and 1m deep all as specified in srl no 22 of appendix a , m and l for pcc type b1 using 20 mm graded stone aggregate all as specified in srl no 23 of appendix a , supply installation testing and commissioning of xlpe cable sizes 4 core 16 sqmm all as specified in srl no 24 of appendix a , m and l for excavation in trenches for cable laying all as specified in srl no 25 of appendix a , m and l for returning filling including spreading leveling watering in layers not exceeding 25 cm all as specified in srl no 26 of appendix a , m and l for removing excavated material all as specified in srl no 27 of appendix a , m and l for sand cushioning all as specified in srl no 28 of appendix a , m and labour for old size sub class b bricks laid in trenches all as specified in srl no 29 of appendix a , m and l for earthing with galvanized steel earth plate size 60cm 60cm 6mm thick all as specified in srl no 30 of appendix a , supply installation testing and commissioning of lt panel all as specified in srl no 31 of appendix a , supply installation testing and commissioning of deep freezer having hard top double door cap not less than 500 ltrs all as specified in srl no 32 of appendix a , m and l for point wiring with copper conductor cable 2 point 5sqmm all as specified in srl no 33 of appendix a , s and f switch socket 6a obliq 16a 5 in 1 flush type with gang box all as specified in srl no 34 of appendix a , supply installation testing and commissioning of inverter technology hot and cold split ac of cap 1 point 5 tr all as specified in srl no 35 of appendix a , s and f single pole and neutral steel metal enclosure with two pin and earth plug and socket with one single pole mcb of 32 amps , m and l for ac sub main wiring with 4 sqmm 1 core all as specified in srl no 36 of appendix a , s and f heavy duty copper pipe half inch dia all as specified in srl no 37 of appendix a , s and f heavy duty copper pipe 1 obliq 4 inch dia all as specified in srl no 38 of appendix a , s and f pvc drain pipes of suitable size 25 mm , supply installation testing and commissioning of inverter technology hot and cold split ac of cap 2 tr all as specified in srl no 39 of appendix a , m and l for ac sub main wiring with single core 6 sqmm all as specified in srl no 40 of appendix a , s and f heavy duty copper pipe of size 15mm all as specified in srl no 41 of appendix a , s and f heavy duty copper pipe of size 10mm all as specified in srl no 42 of appendix a , automatic line voltage correctors (step type) for domestic use (stabilizer) conforming to is, supply installation testing and commissioning of analgue addressable 1 loop control panel all as specified in srl no 1 of appendix a, supply installation testing and commissioning of analogue addressable multi sensor with baseall as specified in srl no 1 of appendix a, sitcofanalogue addressable manual call point all as specified in srl no 3 of appendix a, sitcof intelligent loop powered wall sounder beacon with base all as specified in srl no 4 of appendix a, s and l 2 core 1 point 5 sqmm fire alarm armoured cable all as specified in srl no 5 of appendix a, supply installation testing and commissioning of industrial ductable super cooler all as specified in srl no 6 of appendix a, m and l for fabrication installation balancing of site fabricated gss sheet metal rectangular ducting all as specified in srl no 7of appendix a, m and l for xlpe insulation high quality xlpe aluminum with form 9mm insulation for duct all as specified in srl no 8of appendix a, s and f of imported air grills with auto swing all as specified in srl no 9 of appendix a, s and f of lack phase voltage power fluctuation all as specified in srl no 10 of appendix a, sfc of fire retardant anti vibration canvas connector all as specified in srl no 11 of appendix a, m and l for iron frame stand for mounting of machine and fixing on location all as specified in srl no 12 of appendix a, m and l for sub main wiring with 1 core 4 sqmm pvc insulated copper conductor all as specified in srl no 13 of appendix a, s and f 6 core 1 point 5 sqmm copper conductor cable all as specified in srl no 14 of appendix a, supply installation of water storage tank cap 1000 ltr 3 layer all as specified in srl no 15 of appendix a, s and f including all fittings gi pipe medium grade of 20 mm dia all as specified in srl no 16 of appendix a, s and f including all fittings gi pipe medium grade of 15mm dia all as specified in srl no 17 of appendix a, s and fixing gun metal gate or stop valves with iron wheel head all as specified in srl no 18 of appendix a, s and f ball valves ptmt 20mm all as specified in srl no 19 of appendix a, s and f pvc connection pipe of 15 mm bore all as specified in srl no 20 of appendix a, s and f pvc flexible drain pipe of size 30 all as specified in srl no 21 of appendix a, cutting existing road hard standing with width not exceeding 750 mm and 1m deep all as specified in srl no 22 of appendix a, m and l for pcc type b1 using 20 mm graded stone aggregate all as specified in srl no 23 of appendix a, supply installation testing and commissioning of xlpe cable sizes 4 core 16 sqmm all as specified in srl no 24 of appendix a, m and l for excavation in trenches for cable laying all as specified in srl no 25 of appendix a, m and l for returning filling including spreading leveling watering in layers not exceeding 25 cm all as specified in srl no 26 of appendix a, m and l for removing excavated material all as specified in srl no 27 of appendix a, m and l for sand cushioning all as specified in srl no 28 of appendix a, m and labour for old size sub class b bricks laid in trenches all as specified in srl no 29 of appendix a, m and l for earthing with galvanized steel earth plate size 60cm 60cm 6mm thick all as specified in srl no 30 of appendix a, supply installation testing and commissioning of lt panel all as specified in srl no 31 of appendix a, supply installation testing and commissioning of deep freezer having hard top double door cap not less than 500 ltrs all as specified in srl no 32 of appendix a, m and l for point wiring with copper conductor cable 2 point 5sqmm all as specified in srl no 33 of appendix a, s and f switch socket 6a obliq 16a 5 in 1 flush type with gang box all as specified in srl no 34 of appendix a, supply installation testing and commissioning of inverter technology hot and cold split ac of cap 1 point 5 tr all as specified in srl no 35 of appendix a, s and f single pole and neutral steel metal enclosure with two pin and earth plug and socket with one single pole mcb of 32 amps, m and l for ac sub main wiring with 4 sqmm 1 core all as specified in srl no 36 of appendix a, s and f heavy duty copper pipe half inch dia all as specified in srl no 37 of appendix a, s and f heavy duty copper pipe 1 obliq 4 inch dia all as specified in srl no 38 of appendix a, s and f pvc drain pipes of suitable size 25 mm, supply installation testing and commissioning of inverter technology hot and cold split ac of cap 2 tr all as specified in srl no 39 of appendix a, m and l for ac sub main wiring with single core 6 sqmm all as specified in srl no 40 of appendix a, s and f heavy duty copper pipe of size 15mm all as specified in srl no 41 of appendix a, s and f heavy duty copper pipe of size 10mm all as specified in srl no 42 of appendix a

Latest Tender Detail from indian army for the tender for supply installation testing and commissioning of analgue addressable 1 loop control panel all as specified in srl no 1 of appendix a , supply installation testing and commissioning of analogue addressable multi sensor with baseall as specified in srl no 1 of appendix a , sitcofanalogue addressable manual call point all as specified in srl no 3 of appendix a , sitcof intelligent loop powered wall sounder beacon with base all as specified in srl no 4 of appendix a , s and l 2 core 1 point 5 sqmm fire alarm armoured cable all as specified in srl no 5 of appendix a , supply installation testing and commissioning of industrial ductable super cooler all as specified in srl no 6 of appendix a , m and l for fabrication installation balancing of site fabricated gss sheet metal rectangular ducting all as specified in srl no 7of appendix a , m and l for xlpe insulation high quality xlpe aluminum with form 9mm insulation for duct all as specified in srl no 8of appendix a , s and f of imported air grills with auto swing all as specified in srl no 9 of appendix a , s and f of lack phase voltage power fluctuation all as specified in srl no 10 of appendix a , sfc of fire retardant anti vibration canvas connector all as specified in srl no 11 of appendix a , m and l for iron frame stand for mounting of machine and fixing on location all as specified in srl no 12 of appendix a , m and l for sub main wiring with 1 core 4 sqmm pvc insulated copper conductor all as specified in srl no 13 of appendix a , s and f 6 core 1 point 5 sqmm copper conductor cable all as specified in srl no 14 of appendix a , supply installation of water storage tank cap 1000 ltr 3 layer all as specified in srl no 15 of appendix a , s and f including all fittings gi pipe medium grade of 20 mm dia all as specified in srl no 16 of appendix a , s and f including all fittings gi pipe medium grade of 15mm dia all as specified in srl no 17 of appendix a , s and fixing gun metal gate or stop valves with iron wheel head all as specified in srl no 18 of appendix a , s and f ball valves ptmt 20mm all as specified in srl no 19 of appendix a , s and f pvc connection pipe of 15 mm bore all as specified in srl no 20 of appendix a , s and f pvc flexible drain pipe of size 30 all as specified in srl no 21 of appendix a , cutting existing road hard standing with width not exceeding 750 mm and 1m deep all as specified in srl no 22 of appendix a , m and l for pcc type b1 using 20 mm graded stone aggregate all as specified in srl no 23 of appendix a , supply installation testing and commissioning of xlpe cable sizes 4 core 16 sqmm all as specified in srl no 24 of appendix a , m and l for excavation in trenches for cable laying all as specified in srl no 25 of appendix a , m and l for returning filling including spreading leveling watering in layers not exceeding 25 cm all as specified in srl no 26 of appendix a , m and l for removing excavated material all as specified in srl no 27 of appendix a , m and l for sand cushioning all as specified in srl no 28 of appendix a , m and labour for old size sub class b bricks laid in trenches all as specified in srl no 29 of appendix a , m and l for earthing with galvanized steel earth plate size 60cm 60cm 6mm thick all as specified in srl no 30 of appendix a , supply installation testing and commissioning of lt panel all as specified in srl no 31 of appendix a , supply installation testing and commissioning of deep freezer having hard top double door cap not less than 500 ltrs all as specified in srl no 32 of appendix a , m and l for point wiring with copper conductor cable 2 point 5sqmm all as specified in srl no 33 of appendix a , s and f switch socket 6a obliq 16a 5 in 1 flush type with gang box all as specified in srl no 34 of appendix a , supply installation testing and commissioning of inverter technology hot and cold split ac of cap 1 point 5 tr all as specified in srl no 35 of appendix a , s and f single pole and neutral steel metal enclosure with two pin and earth plug and socket with one single pole mcb of 32 amps , m and l for ac sub main wiring with 4 sqmm 1 core all as specified in srl no 36 of appendix a , s and f heavy duty copper pipe half inch dia all as specified in srl no 37 of appendix a , s and f heavy duty copper pipe 1 obliq 4 inch dia all as specified in srl no 38 of appendix a , s and f pvc drain pipes of suitable size 25 mm , supply installation testing and commissioning of inverter technology hot and cold split ac of cap 2 tr all as specified in srl no 39 of appendix a , m and l for ac sub main wiring with single core 6 sqmm all as specified in srl no 40 of appendix a , s and f heavy duty copper pipe of size 15mm all as specified in srl no 41 of appendix a , s and f heavy duty copper pipe of size 10mm all as specified in srl no 42 of appendix a , automatic line voltage correctors (step type) for domestic use (stabilizer) conforming to is, supply installation testing and commissioning of analgue addressable 1 loop control panel all as specified in srl no 1 of appendix a, supply installation testing and commissioning of analogue addressable multi sensor with baseall as specified in srl no 1 of appendix a, sitcofanalogue addressable manual call point all as specified in srl no 3 of appendix a, sitcof intelligent loop powered wall sounder beacon with base all as specified in srl no 4 of appendix a, s and l 2 core 1 point 5 sqmm fire alarm armoured cable all as specified in srl no 5 of appendix a, supply installation testing and commissioning of industrial ductable super cooler all as specified in srl no 6 of appendix a, m and l for fabrication installation balancing of site fabricated gss sheet metal rectangular ducting all as specified in srl no 7of appendix a, m and l for xlpe insulation high quality xlpe aluminum with form 9mm insulation for duct all as specified in srl no 8of appendix a, s and f of imported air grills with auto swing all as specified in srl no 9 of appendix a, s and f of lack phase voltage power fluctuation all as specified in srl no 10 of appendix a, sfc of fire retardant anti vibration canvas connector all as specified in srl no 11 of appendix a, m and l for iron frame stand for mounting of machine and fixing on location all as specified in srl no 12 of appendix a, m and l for sub main wiring with 1 core 4 sqmm pvc insulated copper conductor all as specified in srl no 13 of appendix a, s and f 6 core 1 point 5 sqmm copper conductor cable all as specified in srl no 14 of appendix a, supply installation of water storage tank cap 1000 ltr 3 layer all as specified in srl no 15 of appendix a, s and f including all fittings gi pipe medium grade of 20 mm dia all as specified in srl no 16 of appendix a, s and f including all fittings gi pipe medium grade of 15mm dia all as specified in srl no 17 of appendix a, s and fixing gun metal gate or stop valves with iron wheel head all as specified in srl no 18 of appendix a, s and f ball valves ptmt 20mm all as specified in srl no 19 of appendix a, s and f pvc connection pipe of 15 mm bore all as specified in srl no 20 of appendix a, s and f pvc flexible drain pipe of size 30 all as specified in srl no 21 of appendix a, cutting existing road hard standing with width not exceeding 750 mm and 1m deep all as specified in srl no 22 of appendix a, m and l for pcc type b1 using 20 mm graded stone aggregate all as specified in srl no 23 of appendix a, supply installation testing and commissioning of xlpe cable sizes 4 core 16 sqmm all as specified in srl no 24 of appendix a, m and l for excavation in trenches for cable laying all as specified in srl no 25 of appendix a, m and l for returning filling including spreading leveling watering in layers not exceeding 25 cm all as specified in srl no 26 of appendix a, m and l for removing excavated material all as specified in srl no 27 of appendix a, m and l for sand cushioning all as specified in srl no 28 of appendix a, m and labour for old size sub class b bricks laid in trenches all as specified in srl no 29 of appendix a, m and l for earthing with galvanized steel earth plate size 60cm 60cm 6mm thick all as specified in srl no 30 of appendix a, supply installation testing and commissioning of lt panel all as specified in srl no 31 of appendix a, supply installation testing and commissioning of deep freezer having hard top double door cap not less than 500 ltrs all as specified in srl no 32 of appendix a, m and l for point wiring with copper conductor cable 2 point 5sqmm all as specified in srl no 33 of appendix a, s and f switch socket 6a obliq 16a 5 in 1 flush type with gang box all as specified in srl no 34 of appendix a, supply installation testing and commissioning of inverter technology hot and cold split ac of cap 1 point 5 tr all as specified in srl no 35 of appendix a, s and f single pole and neutral steel metal enclosure with two pin and earth plug and socket with one single pole mcb of 32 amps, m and l for ac sub main wiring with 4 sqmm 1 core all as specified in srl no 36 of appendix a, s and f heavy duty copper pipe half inch dia all as specified in srl no 37 of appendix a, s and f heavy duty copper pipe 1 obliq 4 inch dia all as specified in srl no 38 of appendix a, s and f pvc drain pipes of suitable size 25 mm, supply installation testing and commissioning of inverter technology hot and cold split ac of cap 2 tr all as specified in srl no 39 of appendix a, m and l for ac sub main wiring with single core 6 sqmm all as specified in srl no 40 of appendix a, s and f heavy duty copper pipe of size 15mm all as specified in srl no 41 of appendix a, s and f heavy duty copper pipe of size 10mm all as specified in srl no 42 of appendix a in new delhi, delhi,. Reference number 15001420. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!

T18 Ref No:15001420
Tender ID:GEM/2026/B/7382565
Tender Agency:indian army
City:new delhi
State:delhi
Description :total quantity = 1708
Tender Value:Refer Document
Tender EMD:Refer Document
Tender Fee:Refer Document
Published Date:Apr 10, 2026
Due Date:Apr 20, 2026
Tender Opening Date:Apr 20, 2026
Tender DocumentsDownload Document
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Inquiry