Latest Tender Detail from nuclear power corporation of india limited NPCIL for the corrigendum tender for item-1 , item-2 , item-3 , item-4 , item-5 , item-6 , item-7 , item-8 , item-9 , item-10 , item-11 , item-12 , item-13 , item- 14 , item-15 , item-16 , item-17 , item-18 , item-19 , item-20 , item-21 , item-22 , item-23 , item-24 , item-25 , item-26 , item-27 , item-28 , item-29 , item-30 , item-31 , item-32 , item-33 , item-34 , item-35 , item-36 , item-37 , item-38 , item-39 , item-40 , item-41 , item-42 , item-43 , item-44 , item-45 , item-46 , item-47 , item-48 , item-49 , item-50 , item-51 , item-52 , item-53 , item-54 , item-55 , item-56 , item-57 , item-58 , item-59 , item-60 , item-61 , item-62 , item-63 , item-64 , item-65, indicating meters and transducer, m/s meco make ac ammeter, model ml72, input 0-5 a dc, scale 0-2500 a ac, deflection angle 240 degree, accuracy 2.5% of full scale as per attached specifications., m/s meco make ac ammeter, model ml110, input 0-5 a dc, scale 0-800 a ac, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make ac ammeter, model ml110, input 0-5 a dc, scale 0-200 a ac, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make ac ammeter, model ml110, input 0-5 a dc, scale 0-1000 a ac, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make ac ammeter model mlc110, input ctr 2500/5 a ac, scale 0-2500 a ac deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make ac ammeter model mlc110, input ctr 1500/5 a ac, scale 0-1500 a ac, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make ac ammeter model mlc110, input ctr 800/5 a ac, scale 0-800 a ac, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make ac ammeter model mlc144, input ctr 1200/5 a ac, scale 0-1200 a ac, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make ac ammeter model mlc110, input ctr 150/5 a ac, scale 0-150 a ac, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make model ml110, input (-15)-0-(+75)mv dc, scale (-500)-0-(+2500) a dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc ammeter model ml110, input 0-50 mv dc, scale 0-40 a dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc ammeter model ml110, input 0-75 mv dc, scale 0-600 a dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc ammeter model ml110, input 0-50 mv dc, scale 0-400 a dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc ammeter model ml110, input 0-75 mv dc, scale 0-75 a dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc ammeter model ml110, input 0-75 mv dc, scale 0-300 a dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc ammeter model ml110, input 0-75 mv dc, scale 0-2000 a dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc ammeter model ml110, input 0-75 mv dc, scale 0-30 a dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc ammeter model m96, input (-75)-0-(+75) mv dc, scale (-50)-0-(+50) a dc, deflection angle 90 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc ammeter model ml72, input 0-75 mv dc, scale 0-3000 a dc, deflection angle 240 degree, accuracy 2.5% of full scale as per attached specifications., m/s meco make dc ammeter model ml110, input 0.2-1 a dc, scale 0.2-1 a dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc ammeter model ml110, input 0-5 a dc, scale 0-5 a dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc ammeter model ml110, input 0-1000 micro a dc, scale 0-1000 micro a dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc ammeter model m96, input 0-5 a dc, scale 0-5 a dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make ac voltmeter model mlc110, input ptr 420/120 v ac, scale 0-500 v ac, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make ac voltmeter model mlc144, input ptr 420/120 v ac, scale 0-500 v ac, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make ac voltmeter model ml72, input 0-10 ma dc, scale 0-25 kv ac, deflection angle 240 degree, accuracy 2.5% of full scale as per attached specifications., m/s meco make ac voltmeter model mlc72, input 0-150 v ac , scale 0-150 v ac, deflection angle 240 degree, accuracy 2.5% of full scale as per attached specifications., m/s meco make ac voltmeter model mlc110, input 0-150 v ac , scale 0-150 v ac, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc voltmeter model ml110, input 0-400 v dc , scale 0-400 v dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc voltmeter model ml110, input 0-75 v dc , scale 0-75 v dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc voltmeter model ml110, input 0-300 v dc , scale 0-300 v dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc voltmeter model m96, input 0-150 v dc , scale 0-150 v dc, deflection angle 90 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc voltmeter model m96, input 0-50 v dc , scale 0-50 v dc, deflection angle 90 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc voltmeter model ml72, input 0-60 v dc , scale 0-60 v dc, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make dc voltmeter model ml72, input 0-60 v dc , scale 0-60 v dc, deflection angle 240 degree, accuracy 2.5% of full scale as per attached specifications., m/s meco make dc voltmeter model ml72, input (-400)-0-(+400) v dc , scale (-400)-0-(+400) v dc, deflection angle 240 degree, accuracy 2.5% of full scale as per attached specifications., m/s meco make dc voltmeter model ml72, input (-300)-0-(+300) v dc , scale (-300)-0-(+300) v dc, deflection angle 90 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make wattmeter model 110lw33, input ctr 2500/5 a ac, input ptr 420/120 v ac, scale 0-1750 kw, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make wattmeter model ml110, input 4-20 ma dc, scale (-60)-0-(+300) mw, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make wattmeter model ml110, input 4-20ma dc, scale (-15)-0-(+75) mw, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make wattmeter model ml110, input 4-20 ma dc, scale (-50)-0-(+250) mw, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make wattmeter model ml72, input 4-20 ma dc, scale (-50)-0-(+500) kw, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make wattmeter model ml110, input 4-20 ma dc, scale (-50)-0-(+500) kw, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make wattmeter model ml72, input 4-20 ma dc, scale (-0.4)-0-(+2) mw, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make wattmeter model ml96, input 4-20 ma dc, scale 0-1200 kw, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make var meter model 110lv33, input ctr 2500/5 a ac, ptr 420/120 v ac, scale (-1000)-0-(+1000) kvar, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make var meter model 144lv33, input ctr 1200/5 a ac, ptr 420/120 v ac, scale 0-800 kvar, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make var meter model ml72, input 4-20 ma dc, scale (-0.4)-0-(+2) mvar, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make var meter model ml110, input 4-20 ma dc, scale (-500)-0-(+500) kvar, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make var meter model ml110, input 4-20 ma dc, scale (-60)-0-(+300) mvar, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make var meter model ml110, input 4-20 ma dc, scale (-15)-0-(+75) mvar, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make var meter model ml110, input 4-20 ma dc, scale (-100)-0-(+200) mvar, deflection angle 240 degree, accuracy 1.5% of full scale as per attached specifications., m/s meco make frequency meter model fl110, input ptr 420/120 v ac, scale 45-55 hz, deflection angle 240 degree, accuracy 1% of full scale as per attached specifications., m/s meco make frequency meter model f72, input ptr 420/120 v ac, scale 45-55 hz, deflection angle 90 degree, accuracy 1% of full scale as per attached specifications., m/s meco make active power transducer model wt33, type 3 phase-2 element-3 wire, input ctr 2500/5 a ac, input ptr 420/120 v ac, output 4-20 ma dc corresponding to scale(-0.4)-0-(+2) mw , load 500 ohm max., aux. supply 85-265 v ac/dc, mounting din rail, accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications., m/s meco make active power transducer model wt33, type 3 phase-2 element-3 wire, input ctr 800/5 a ac, input ptr 420/120 v ac, output 4-20 ma dc corresponding to scale(-50)-0-(+500) kw , load 500 ohm max., aux. supply 85-265 v ac/dc, mounting din rail, accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications., m/s meco make active power transducer model wt33, type 3 phase-2 element-3 wire, input ctr 1200/5 a ac, input ptr 420/120 v ac, output 4-20 ma dc corresponding to scale 0-920 kw , load 500 ohm max., aux. supply 85-265 v ac/dc, mounting din rail, accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications., m/s meco make active power transducer model wt33, type 3 phase-2 element-3 wire, input ctr 800/5 a ac, input ptr 230 kv/115 v ac, output 4-20 ma dc corresponding to scale (-60)-0-(+300) mw , load 500 ohm max., aux. supply 85-265 v ac/dc, mounting din rail, accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications., m/s meco make active power transducer model wt33, type 3 phase-2 element-3 wire, input ctr 200/5 a ac, input ptr 230 kv/115 v ac, output 4-20 ma dc corresponding to scale (-15)-0-(+75) mw , load 500 ohm max., aux. supply 85-265 v ac/dc, mounting din rail, accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications, m/s meco make active power transducer model wt33, type 3 phase-2 element-3 wire, input ctr 1500/5 a ac, input ptr 420/120 v ac, output 4-20 ma dc corresponding to scale 0-1200 kw , load 500 ohm max., aux. supply 85-265 v ac/dc, mounting din rail, accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications, m/s meco make reactive power transducer model rpt33, type 3 phase-2 element-3 wire, input ctr 2500/5 a ac, input ptr 420/120 v ac, output 4-20 ma dc corresponding to scale (-0.4)-0-(+2) mvar , load 500 ohm max., aux. supply 85-265 v ac/dc, mounting din rail, accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications, m/s meco make reactive power transducer model rpt33, type 3 phase-2 element-3 wire, input ctr 1200/5 a ac, input ptr 420/120 v ac, output 4-20 ma dc corresponding to scale 0-920 kvar, load 500 ohm max., aux. supply 85-265 v ac/dc, mounting din rail, accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications, m/s meco make reactive power transducer model rpt33, type 3 phase-2 element-3 wire, input ctr 800/5 a ac, input ptr 230kv/115 v ac, output 4-20 ma dc corresponding to scale (-60)-0-(+300) mvar , load 500 ohm max., aux. supply 85-265 v ac/dc, mounting din rail, accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications, m/s meco make reactive power transducer model rpt33, type 3 phase-2 element-3 wire, input ctr 200/5 a ac, input ptr 230kv/115 v ac, output 4-20 ma dc corresponding to mvar , load 500 ohm max., aux. supply 85-265 v ac/dc, mounting din rail, accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications, m/s meco make reactive power transducer model rpt33, type 3 phase-2 element-3 wire, input ctr 800/5 a ac, input ptr 420/120 v ac, output 4-20 ma dc corresponding to scale (-500)-0-(+500) kvar , load 500 ohm max., aux. supply 85-265 v ac/dc, mounting din rail, accuracy 0.5%of span, provision of zero and span adjustment as per attached specifications in rawatbhata, rajasthan,. Reference number 14964773. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!