Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Man power service Tenders List

Latest Man power service Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Man power service tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Man power service tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Man power service Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Man power service tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Man power service Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Man power service Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Man power service Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Man power service tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Man power service Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Man power service sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Man power service tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Man power service tenders.

Is EMD mandatory for all Man power service tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Man power service work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Man power service tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Man power service Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15866874
new Tender
Location : kolar , karnataka
new Tender

Tender Value : 926923.8
Due Date : Jul 18, 2026
T18 Ref No : 15875280
new Tender
Location : ajmer , rajasthan
Source : GEM Tenders
new Tender

tender for transportation of up to 20 kva dea sets , transportation of more than 20 kva and upto 55 kva dea sets , unloading up to 20 kva dea sets , unloading more than 20 kva and upto 55 kva dea , itc of up to 20 kva dea sets on existing foundation , itc of more than 20 kva and upto 55 kva dea , labour charges for top overhauling of existing dea sets up to 20 kva , replacement of the liner assembly with rubber ring dea sets up to 20 kva , replacement of the piston set without piston ring set dea sets up to 20 kva , replacement of the piston ring set dea sets up to 20 kva , replacement of the set of gasket including head gasket dea sets up to 20 kva , replacement of the o ring set dea sets up to 20 kva , replacement of the cr bearing dea sets up to 20 kva , replacement of the main bearing dea sets up to 20 kva , replacement of the oil pressure guage dea sets up to 20 kva , replacement of the front oil seal of crank shaft dea sets up to 20 kva , replacement of the back oil seal of crank shaft dea sets up to 20 kva , repairing of cylinder head , repairing of up to 20 kva dea sets crank shaft , transportation charges up to 50 km for alternator up to 55 kva , transportation charges more than 51 to 100 km for alternator up to 55 kva , rewinding of main stator winding of alternator up to 20 kva , rewinding of main rotor winding of alternator up to 20 kva , rewinding of main stator winding of alternator more than 20 kva and upto 55 kva , rewinding of main rotor winding of alternator more than 20 kva and upto 55 kva , exciter stator winding of alternator up to 55 kva , exciter rotor winding of alternator up to 55 kva , replacement or repairing of avr , replacement or repairing of power diode for rotating rectifier assembly , replacement or repairing of bearing suitable for above 20 kva alternator , providing of 2 core 16 sqmm , providing of 4 core 16 sqmm , laying of one no upto 35 sq. mm on wall surface , laying of one no upto 35 sq. mm direct in ground , laying of one no upto 35 sq. mmin the existing rcc or hume or metal pipe , supply and making end termination for 2 x 10 sq. mm 19 mm , supply and making end termination for 4 x 16 sq. mm 28 mm , providing and fixing 6 swg dia g.i. wire , supply installation testing and commissioning of 32 amps four pole on load side handle operated change over switch , supply installation testing and commissioning of 63 amps 2 pole on load side handle operated change over switch , supply installation testing and commissioning of 63 amps four pole on load side handle operated change over switch , providing and fixing 63 amp tpn disconnector fuse switch unit , repairing of fuel injection pump fip, nozzle and injectors ,, rc for repairing servicing shifting of dea sets at hub sites under ba udaipur, visit charges to attend fault of dea set on call basis / complaint basis on behalf of written job order from sde(e) concerned for different te / bts sites under jurisidication including attending the minor faults involving no material and submit detailed report for major fault to the engineering -in-charge i/c fare charges to visit the site from hq etc complete as reqd., pdg & making of general servicing of the up to 20 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., pdg & making of general servicing of the more than 20 kva & upto 32.5 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., pdg & making of general servicing of the more than 32.5 kva & up to 55 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., replacement of diesel filter element set ( 1 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter element ( 1/2 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter element ( 1 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter set suitable for e/a set of 50/55 kva in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of lubricating oil multi grade ( 20w40) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of steel wire braided fuel pipe line in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of stop solenoid 12 volt in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of starting key with switch in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of mechanical type rpm cum hr meter in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of mechanical type rpm cum hr meter chain in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of battery leads red & black standard length & size i/c terminals in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of coolant for radiator of superior quality or as recommended by manufacturer in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of v-belt in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of hose pipe set with clips in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of techo drive unit in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of fuel feed pump assembly in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of solid state smps or scr based battery chargers in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of push button switch for start/ stop/reset in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of 12 v dc / 220 v ac hr meter counter type in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), supplying & fixing of 12 volt battery operated self starter suitable for starting of engine i/c fixing the same on the dg set making connections testing etc. complete as reqd. ( make- autolek or similar superior make), supplying & fixing of 12 volt battery charging alternator on the existing dg set i/c making connections testing etc. complete as reqd. ( make -autolek or similar superior make), repairing and servicing of the 12 volt battery charging alternator for dg set i/c greasing, oiling, making connections testing etc. complete as reqd., repairing & general servicing of the existing faulty radiator up to 55 kva diesel engine alternator set by repairing of leakage and cleaning of copper tubes with help of cleaning agents, dismentling of radiator assembly including transportation, brazing and testing for leakage and re-installation after repairing the same etc. reqd., pdg general servicing and repairing of 12 volts engine starting self that i/c dismentalling of equipments, greasing and oiling of bearing and other parts , cleaning of self with petrol , replacement of carbon brush , housing etc. complete checking of self and testing and fixing with proper alignment with gears etc complete as reqd., dismentalling of existing up to 20 kva dea sets in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc. set from existing position of te / bts site under ed jaipur etc. and reparing of any damage during dismentling by making good the same etc. complete as reqd., dismentalling of existing more than 20 kva & upto 55 kva dea sets in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc. set from existing position of te / bts site under ed jaipur etc. and reparing of any damage during dismentling by making good the same etc. complete as reqd., extra for shifting of existing dea set up to 20 kva capacity from rooftop of the building to ground floor / loading vehicle with the help of chain pulley / crane by ensuring safety to the existing construction at site and reparing of any damage during shifting / dismentling by making good the same etc. complete as reqd., loading of existing up to 20 kva dea sets from ground floor to loading vehicle with the help of chain pulley / crane / man power etc. complete as reqd., loading of existing more than 20 kva & upto 55 kva dea sets from ground floor to loading vehicle with the help of chain pulley / crane / man power etc. complete as reqd., transportation of up to 20 kva dea sets along with all accessories etc from te / bts site of ssa under ed jaipur to store / any place in same ssa as directed by engg. in charge by transport by truck / loading vehicle etc. complete as reqd., transportation of more than 20 kva & upto 55 kva dea sets along with all accessories etc from te / bts site of ssa under ed jaipur to store / any place in same ssa as directed by engg. in charge by transport by truck / loading vehicle etc. complete as reqd., unloading of existing dea sets of up to 20 kva dea sets from loading vehicle to place of shifting / store along with all accessories etc as directed by engg. in charge with the help of chain pulley / crane / man power etc. complete as reqd., unloading of existing dea sets of more than 20 kva & upto 55 kva dea from loading vehicle to place of shifting / store along with all accessories etc as directed by engg. in charge with the help of chain pulley / crane / man power etc. complete as reqd., installation, testing and commissioning of existing dea sets of up to 20 kva dea sets on existing foundation / floor at site along with canopy & all other accessories i/c making connections, power and control cable, earthing connections etc. complete as per requirement at site., installation, testing and commissioning of existing dea sets of more than 20 kva & upto 55 kva dea on existing foundation / floor at site along with canopy & all other accessories i/c making connections, power and control cable, earthing connections etc. complete as per requirement at site., labour charges for top overhauling of existing dea sets up to 20 kva capacity i/c dismentalling of all parts, radiator cleaning, replacement of engine oil coolant, replacement of belts safties, meters if reqd and calibration of engine as per manufaturer reccommendations., replacement of the liner assembly with rubber ring in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts, testing etc as reqd., replacement of the piston set without piston ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of thepiston ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the set of gasket i/c head gasket in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the o ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of thecr bearing in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the main bearing in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the oil pressure guage in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the front oil seal ( crank shaft ) in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the back oil seal ( crank shaft ) in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., repairing of cylinder head ( one job for each head ) with replacement of valve seat, valve guide, valves and stamp seal i/c grinding , lapping of valves i/c turning, grinding of head etc complete as reqd., repairing of up to 20 kva dea sets crank shaft i/c grinding, lapping, bushing, allignement etc complete as reqd., transportation charges up to 50 km for alternator of various capacity up to 55 kva from site to the nearest workshop & back after repairing i/c dismentling, loading, unloading, transportation, safe handling & i/c reinstallation etc. and testing on existing load for at least one hour after commissioning of the alternator etc. complete as reqd., transportation charges more than 51 to 100 km for alternator of various capacity up to 55 kva from site to the nearest workshop & back after repairing i/c dismentling, loading, unloading, transportation, safe handling & i/c reinstallation etc. and testing on existing load for at least one hour after commissioning of the alternator etc. complete as reqd., rewinding of main stator winding of alternator capacity up to 20 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main rotor winding of alternator capacity up to 20 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main stator winding of alternator capacity more than 20 kva & upto 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main rotor winding of alternator capacity more than 20 kva & upto 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of exciter stator winding of alternator capacity up to 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of exciter rotor winding of alternator capacity up to 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., replacement / repairing of avr make national or s.s. for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., replacement / repairing of power diode for rotating rectifier assembly for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., replacement / repairing of bearing suitable for above 20 kva alternator for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., providing of 2 core 16 sqmm pvc insulated and pvc sheathed aluminium conductor armoured cable of 1.1 kv grade confirming to relevent is-specification complete as reqd. ( note - cable shall be provided at site / handed over to ssa authority as per direction of engg. in charge ), providing of 4 core 16 sqmm pvc insulated and pvc sheathed aluminium conductor armoured cable of 1.1 kv grade confirming to relevent is-specification complete as reqd. ( note - cable shall be provided at site / handed over to ssa authority as per direction of engg. in charge ), laying and fixing of one no upto 35 sq. mm (clamped with 1mm thick saddle) pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required., laying of one no upto 35 sq. mm pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required., laying of one no upto 35 sq. mm pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required., supplying and making end termination with brass compression gland and aluminium lugs for 2 x 10 sq. mm (19 mm) for pvc insulated and pvc sheathed/xlpe aluminium conductor cable of 1.1 kv grade as required., supplying and making end termination with brass compression gland and aluminium lugs for 4 x 16 sq. mm ( 28 mm) for pvc insulated and pvc sheathed/xlpe aluminium conductor cable of 1.1 kv grade as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required., supply installation testing and commissioning of 32 amps four pole on load side handle operated change over switch in steel enclosure capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., supply installation testing and commissioning of 63 amps 2 pole on load side handle operated change over switch in steel enclosure capable of working 240 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., supply installation testing and commissioning of 63 amps four pole on load side handle operated change over switch in steel enclosure capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., providing and fixing 63 a tpn disconnector fuse switch unit in sheet steel enclosure a/w hrc fuses capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., repairing of fuel injection pump(fip), nozzle & injectors i/c dismantling, transportation of pump, cleaning, repairing, testing and refitting the same on the existing e/a set i/c replacement of faulty components etc. complete as reqd.., supply installation testing and commissioning of 12 volt 88ah lead acid maintenance free battery for testing of above dg set, including installation at last site after repairing of all dg sets.


Tender Value : 0
Due Date : Jun 29, 2026
T18 Ref No : 15805489
live Tender
Location : baran , rajasthan
live Tender

Tender Value : 6152000
Due Date : Jun 21, 2026
T18 Ref No : 15722105
live Tender
Location : parbatsar , rajasthan
live Tender

Tender Value : 3200000
Due Date : Jun 22, 2026
T18 Ref No : 15786954
live Tender
Location : udaipurwati , rajasthan
live Tender

Tender Value : 4000000
Due Date : Jun 22, 2026
T18 Ref No : 15705454
live Tender
Location : nawalgarh , rajasthan
live Tender

Tender Value : 1160000
Due Date : Jun 22, 2026
Published By