Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Gi nut Tenders List

Latest Gi nut Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Gi nut tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Gi nut tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Gi nut Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Gi nut tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Gi nut Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Gi nut Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Gi nut Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Gi nut tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Gi nut Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Gi nut sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Gi nut tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Gi nut tenders.

Is EMD mandatory for all Gi nut tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Gi nut work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Gi nut tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Gi nut Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15826870
new Tender
Location : kamrup , assam
Source : GEM Tenders
new Tender

tender for odu 1 , odu 2 , 4-way cassette unit 1 , 4-way cassette unit 2 , y joints 1 , y joints 2 , cu piping , damper , actuator , nitrile rubber , wiring , mccb , mcb db 1 , mcb db 2 , mcb , allied electrical works , dx coil unit , 4-way cassette unit 3 , ahu , ahu kit , ref gas , control cable , drain pipe , ducting , acoustic nitrile rubber , vfd , strip heater , pdp , al cable 1 , al cable 2, supply installation testing and commissioning of vrf based air conditioning system, supply and itc of modular type variable refrigerant flow/variable refrigerant volume air cooled outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin rotary/scroll compressor(s), minimum two compressors (with individual seperate pcb) for above 6 hp modules/non module, microprocessor based controller, top discharge type condensing unit(s), with r-410-a refrigerant or equivalent, vibration isolators with suitable foundation etc. complete as required, as per nit specifications - 14 hp, supply and itc of modular type variable refrigerant flow/variable refrigerant volume air cooled outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin rotary/scroll compressor(s), minimum two compressors (with individual seperate pcb) for above 6 hp modules/non module, microprocessor based controller, top discharge type condensing unit(s), with r-410-a refrigerant or equivalent, vibration isolators with suitable foundation etc. complete as required, as per nit specifications - 10 hp, supply and itc of following minimum capacity 4 way cassette type indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with dx copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc as per nit specifications - 2.56 tr, supply and itc of following minimum capacity 4 way cassette type indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with dx copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc as per nit specifications - 2.0 tr, supplying, installation, testing and commissioning of odu y/t/multi joints. joints shall be of same original equipment manufacturer (oem) make as of odus and idus, supplying, installation, testing and commissioning of idu y/t/multi joints. joints shall be of same original equipment manufacturer (oem) make as of odus and idus, refrigerant piping for vrf system - supply , installation , testing and commissioning of copper piping in brazed construciton, complete with nitrile rubber insulation, supports/suspenders, as per enclosed specifications. refrigerant piping for suction gas with 19mm thick nitrile insulation & refrigerant piping for liquid gas with 13mm thick nitrile insulation (various capacities as per boq of nit document, supply, installation, testing and commissioning of motorized (on-off type) duct mounted gi volume control damper with enthalpy sensor and necessary control wire for integration within ahu room complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to smacna/is and as per specifications complete etc. as required - damper, supply, installation, testing and commissioning of motorized (on-off type) duct mounted gi volume control damper with enthalpy sensor and necessary control wire for integration within ahu room complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to smacna/is and as per specifications complete etc. as required - actuator, supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell nitrile rubber (class-o) insulation on existing duct as per nit specifications - 25mm, wiring for circuit/ submain wiring along with earth wire as per nit specifications, providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board as per nit specifications, supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess as per nit specifications, supplying and fixing following way, tpn, sheet steel, mcb distribution board, 240 v, on surface/ recess as per nit specifications, supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka mcbs as per boq enclosed with nit document, allied electrical works as per as per boq enclosed with nit document including supply installation testing and commissioning of panels, supply, installation, testing and commissioning of approved make direct expansion (dx) type cooling coil unit for air handling unit (ahu) as per boq/ specifications enclosed with nit document, supply and itc of following minimum capacity 4 way cassette type indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with dx copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc as per nit specifications - 3.2 tr, supply and itc of sheet metal sectionalised construction double skin ahu for vrf/vrv system as per boq/ specifications enclosed with nit document, supply and itc of ahu kit, refrigerent gas - supply and top-up of refrigerent gas r410a., control cable - supply, installation, testing & commissioining of control cum transmission cabling between odu & idu 2c x 1.0 sqmm cu cable in rigid pvc conduit duly supported., drain piping - supply, installation and commissioning of upvc drain piping with 6/9 mm thick closed cell nitrile rubber insulation with all fittings, solvent, necessary accessories and supports. thermal insulation sleeve joints shall be sealed with black tape - 25 mm/32 mm, supply, installation, balancing and commissioning of factory/hand fabricated aluminium sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required - thickness 0.8 mm, supplying and fixing of following thickness open cell acoustic nitrile rubber insulation on existing duct after applying suitable adhesive for nitrile rubber. as per specifications and as required - thickness 10mm., supply, installation,testing, & commissioning of variable friquency drive, supply,installation,testing & commissioning of strip heater along with controller, supply of power distribution panel ac distribution panel board - ip65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, without mcbs etc. as required to be made of customised requirment for outdoor fixing., supply of lt armoured aluminium cable (1.1kv) as per boq/ specifications enclosed with the nit document - 16 sqmm, supply of lt armoured aluminium cable (1.1kv) as per boq/ specifications enclosed with the nit document - 35 sqmm


Tender Value : 0
Due Date : Jul 07, 2026
T18 Ref No : 15828346
new Tender
Location : mumbai , maharashtra
Source : GEM Tenders
new Tender

corrigendum tender for n0214 0033461 , n0214 1223404 , n0214 r003471 , n0214 r003472 , n0214 r003473 , n0214 r003476 , n0214 r010697 , n0214 r010767 , n0214 r010778 , n0257 0000142 , n0266 0000865 , n0266 1225296 , n5305 000848 , n5305 006510 , n5305 094101 , n5305 097102 , n5305 p062620 , n5305 p062621 , n5306 000289 , n5306 000554 , n5306 000626 , n5306 000820 , n5306 000959 , n5306 003517 , n5306 004500 , n5306 004534 , n5306 004615 , n5306 004620 , n5306 004642 , n5306 004676 , n5306 004680 , n5307 000325 , n5307 000330 , n5307 000677 , n5307 000681 , n5310 000715 , n5310 001415 , n5306 062039 , n5310 p06292 , n5310 250261 , n5310 250262 , n5306 062051 , n5310 250264 , n5306 062046 , n5306 062052, 26b53c001, nut steel bsf 5 8, nut plain hex m12, ss bolts 8 4 5 mm, ss bolt size 8 55 mm pitch 1251 mm, ss bolts 8 65mm pitch 1 25mm, bolt size 46 45 mm pitch 2mm, gi bolt and nut 8 35 mm, ss bolt with nut hex head m 10 35mm, bolt 14 45 mm, bolt brass and nut 6 18 mm x length ft head, screw steel 1 x 0ba, nut plain hex head m 8, screw ba pb hex head 1 x 0ba, screw machine ok slotted hd m 12 40 mm, screw, ss hex screw 8 25 mm, hex hd full tread s s screw size m 12 x 25 pitch 1 75 mm, hex head full thread ss screw size m 8 25 pitch 1 25 mm, bolt bsf precision r steel hex hd zinc plated 7 8 2 1 2 l, bolt hex bsw 5 8 3, bolt steel ht 5 8 4, steel bolt and nut m 8 75, ms bolt and nut m 20 65, bolt machine hex hd precision pitch phospted steel 4 6 m 20, bolt machine hex precision brass m 10 35 mm, bolt machine hex head m 14 25 mm, brass bolt m 8 45 mm, brass bolt m 10 35 mm, bolt machine hex ms m 6 40 mm, bolt hex m 16 45 2 mm, bolt machine hex hd ms plated m 20 65 2 5 mm, studs bsf h t steel plain 7 8 2 3 4 long length of metal, stud steel bsf 7 8 4 round h t screwed, stud h t steel 5 8 unc 2 long, stud ht steel 3 4 7 2, nut hex 7 8 bsf carbon molybdenum copper plated, washer spring single type 4 4 23 2 3 mm, ss bolts 14 60 mm full threaded pitch 2 mm, nut stainless steel 10 mm pitch of thread 2 mm non magnetic, ss washer 8 4 mm id 17 mm od 1 6 mm thk, ss washer 10 5 mm id 21 mm od 2 mm thk, ss bolt 20 60 mm full threaded pitch 2 5 mm, ss washer 13 mm id 24 mm od 2 5 mm thk, ss bolt 16 60 mm full threaded pitch 2 mm, ss bolt 20 70 mm full threaded pitch 2 5 mm


Agency / Dept : indian navy
Tender Value : 0
Due Date : Jun 22, 2026
T18 Ref No : 15828774
new Tender
Location : sonitpur , assam
Source : GEM Tenders
new Tender

tender for superstructure of small living shelter of size 6 point10 m x 5 point 22 m x 4 point75 m height with 1 point 50 m enclosed verandah , ceramic tiles of size 600 mm x 600 mm for floor thickness between 9 to 10 mm , white cement conforming to , curtain arrangement drapery and rod made of 25 mm dia and 1600 mm long , distribution box 8 way spn comma 240 volts copper bus bar , mcb spn 240 volts 32 amps , mcb sp 6 to 32 amps , pvc tape 19mm wide 5m long , cable pvc insulated electric cables copper conductor of size 1 point 5 sqmm single core , cable pvc insulated electric cables copper conductor of size 2 point 5 sqmm single core , cable pvc insulated electric cables copper conductor of size 4 sqmm single core , pvc casing capping 1 inch medium grade snow white , pvc casing capping of size 3 oblique 4 inch medium grade snow white , switch piano 5 amp 230 volts flush type one way snow white , led tuble light fittings 15w 230v box type 4 feets , steel screw full thread with rawl plug plug of size 1 1 oblique 2 inch , pvc switch board 7 inch x 4 inch , pvc switch board 8 inch x 10 inch for main switch oblique db , pvc l bend and t junction joint for pvc casing and caping conforming , switch socket combination multipurpose 2 in 1 comma 15a 230v , switch socket combination snow white 5a 230v , service bracket 40mm dia gi tubing medium grade 1 point 5m long , service cable pvc insulated aluminium conductor comma 10 sqmm 2 core , ceiling rose three terminal snow white , led bulk head fitting with glass cover with led lamp 10 watts , pvc flexible wire copper conductor multi stranded , pvc flexible conduit pipe 15mm dia , pvc round oblique square block , exhaust fan 230 volts 300 mm sweep plastic body alongwith louvers and complete fittings , fire exitingusher of 1 kg capacity , monoblock pump set suitable for 230 v single phase system having capacity 2hp , distribution box 2 way with mcb spn 240 volts 10 amps , pvc flexible suction hose pipe 25mm dia heavy duty , non return valve nrv metal 25mm dia , earthing plate 600x600x6mm galvanised steel , ci earthing pit cover of size 300x300x6mm with angle iron isa 20x20x3mm thick ms frame , funnel fitted with 20mm dia gi pipe 1 point 5m long , gi wire 4mm diameter for earthing , charcoal , salt normal , air terminal single pointed aluminium rod 12mm dia and 300mm long , testing point terminal block make of gun metal and phosphorus bronzesize 75x75x25mm , aluminium strips 25x3mm , galvanised iron strip 32x6mm , earthing plate 600x600x6mm galvanised steel suitable for gi strip fittings , insulating pvc block 75x75x30 mm with insulating clamp nut and bolt , individual standalone plastic body smoke alarm , individual standalone plastic body heat alarm , fire ball extinguisher 1 point 3 kg with suitable provision for wall mounting , double sleeping bunk with matress complete , steel bed side locker of size 1000mm x 1520mm x 450mm complete , study chair of size length 56 cm comma height 82 cm and width 56 cmcomma lacquered finish , study table of size 900mm x 600mm x 760mm wih 18 mm thick prelaminated particle complete , looking mirror of size 18 inch x 4 inch fixed with 4 mm thick ply , water dispenser of 230 v 500 watts without refrigerator capacity of 5 lts oblique hour , protable indoor type high quality kero heater metal body ignites type min 8 hrs and above with capacity 4 ltrs , plastic dustbin of capacity 40 ltrs, small living shelter 2457, as per technical specification and store list


Agency / Dept : indian army
Tender Value : 0
Due Date : Jun 27, 2026
T18 Ref No : 15763012
live Tender
Location : etawah , uttar pradesh
Source : GEM Tenders
live Tender

Tender Value : 99500
Due Date : Jun 26, 2026
T18 Ref No : 15779642
live Tender
Location : aligarh , uttar pradesh
Source : GEM Tenders
live Tender

tender for title1 , title2 , title3 , title4 , title5 , title6 , title7 , title8 , title9 , title10 , title11 , title12 , title13, supply of different type of cb ct isolator clamp and jaw of 220 132 33 kv equipments, connector clamp for 245 kv isolator suitable for zebra conductor as per sample complete with hot dip gi nut bolts and washers clamp body shall be made of high conductivity aluminium alloy grade lm6 lm25 ec grade aluminium. casting shall be smooth homogeneous and free from cracks, blow holes and other casting defects, connector clamp for 245 kv ct suitable for zebra conductor as per sample complete with hot dip gi nut bolts and washers clamp shall be suitable for outdoor ehv substation application with corrosion resistant and corona free design, connector clamp for 145 kv current transformer suitable for zebra conductor as per sample complete with hot dip gi nut bolts and washers clamp shall have adequate mechanical strength and low contact resistance as per relevant is iec standards, pg clamp suitable for zebra to zebra conductor 4 bolted type complete with hot dip gi nut bolts and washers clamp body shall be made of high conductivity aluminium alloy with smooth finish and defect free casting, gi perforted cable tray 225 and 250 mm, gi perforted cable tray 75 mm, pg clamp suitable for pather to pather conductor 3 bolted type complete with hot dip gi nut bolts and washers clamp body shall be made of high conductivity aluminium alloy with smooth finish and defect free casting, twin connector clamp for 33 kv ct suitable for twin moose conductor as per sample complete with hot dip gi nut bolts and washers clamp shall be suitable for outdoor ehv substation application with corrosion resistant and corona free design, connector clamp for 145 kv cb suitable for panther conductor as per sample complete with hot dip gi nut bolts and washers clamp shall be suitable for outdoor ehv substation application with corrosion resistant and corona free design, copper bar rectangular half hard size 75x10 mm, connector clamp for 36 kv cb suitable for twin panther conductor as per sample complete with hot dip gi nut bolts and washers clamp shall be suitable for outdoor ehv substation application with corrosion resistant and corona free design, male contact jaw of 132 kv g nandi make isolator made of copper with nuts bolt and washer as per sample, female contact jaw of 220 kv g nandi make isolator made of copper with nuts bolt and washer as per sample


Tender Value : 199750.4
Due Date : Jun 27, 2026
T18 Ref No : 15602540
live Tender
Location : mumbai , maharashtra
Source : GEM Tenders
live Tender

tender for 14 hp air cooled outdoor condensing unit supply , 20 hp air cooled outdoor condensing unit supply , 24 hp air cooled outdoor condensing unit supply , 14 hp outdoor unit installation testing commissioning , 20 hp outdoor unit installation testing commissioning , 24 hp outdoor unit installation testing commissioning , 1.5 tr 4 way cassette indoor unit supply , 4 tr 4 way cassette indoor unit supply , 1.5 tr 4 way cassette indoor unit installation , 4 tr 4 way cassette indoor unit installation , 3 tr split dx cassette air conditioning system supply , 3 tr split dx ac system installation testing commissioning , centralized remote controller unit supply , centralized remote control unit installation testing commissioning , 25.4mm od copper refrigerant pipe supply , 22.2mm od copper refrigerant pipe supply , 19mm od copper refrigerant pipe supply , 15.86mm od copper refrigerant pipe supply , 12.7mm od copper refrigerant pipe supply , 9.5mm od copper refrigerant pipe supply , 25.4mm od copper pipe installation testing commissioning , 22.2mm od copper pipe installation testing commissioning , 19mm od copper pipe installation testing commissioning , 15.86mm od copper pipe installation testing commissioning , 12.7mm od copper pipe installation testing commissioning , 9.5mm od copper pipe installation testing commissioning , vrf refrigerant y and t joints with insulation supply , vrf refrigerant y and t joints installation testing commissioning , 3 core 2.5 sqmm cu shielded communication cable supply , 4 core 2.5 sqmm cu shielded communication cable supply , 2 core 1.5 sqmm cu shielded communication cable supply , 3 core 2.5 sqmm cu cable laying , 4 core 2.5 sqmm cu cable laying , 2 core 1.5 sqmm cu cable laying , pvc condensate drain pipe with insulation supply , pvc condensate drain pipe installation , ms table top stands for outdoor units supply , ms table top stands for outdoor units installation , refrigerant gas r410a supply and filling , 4 core 10 sqmm xlpe armoured copper cable supply , 4 core 16 sqmm xlpe armoured copper cable supply , 4 core 10 sqmm xlpe cable laying testing commissioning , 4 core 16 sqmm xlpe cable laying testing commissioning , aluminium anodized partition for ac enclosure , light point wiring in pvc casing and capping , 2x2 led luminaire 24w recess surface mounted supply , led panel 2x2 24w installation testing commissioning , 4c 50 sqmm xlpe armoured copper cable supply , gi wire 8 swg supply and delivery , armoured cable laying on wall for ac power db , 4c 50 sqmm cable end termination both ends , tpn distribution board 8 way hvac odu , fp isolator 125 amp supply installation testing and commissioning , fp mcb 63 amp supply installation testing and commissioning , fp mcb 40 amp supply installation testing and commissioning , sp and n distribution board 12 way hvac idu , dp mcb 32 amp supply installation testing and commissioning , sp mcb 6 or 10 amp supply installation testing and commissioning , sfu 100a tpn at main switch board supply installation testing and commissioning , chemical earth electrode earthing arrangement supply installation testing and commissioning , camc first year air conditioning system , camc second year air conditioning system , camc third year air conditioning system , camc fourth year air conditioning system , camc fifth year air conditioning system, supply installation testing and commissioning of vrv type ac, supply and delivery of 14 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, supply and delivery of 20 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, supply and delivery of 24 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, installation testing and commissioning of 14 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, installation testing and commissioning of 20 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, installation testing and commissioning of 24 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, supply of 1.5 tr vrf 4 way cassette indoor unit with cooling capacity 12 kw and above power input 110 to 125 w airflow 1800 to 2000 cubic metres per hour noise level less than 35 db at low speed with mandatory auto bypass feature, supply of 4 tr vrf 4 way cassette indoor unit with adequate cooling capacity power input airflow 1800 to 2000 cubic metres per hour noise level less than 35 db at low speed with mandatory auto bypass feature as per specifications, installation testing and commissioning of 1.5 tr vrf 4 way cassette indoor unit including mounting electrical termination control wiring drain piping connection trial run and commissioning complete as required, installation testing and commissioning of 4 tr vrf 4 way cassette indoor unit including mounting electrical termination control wiring drain piping connection trial run and commissioning complete as required, supply of 3 tr split type direct expansion air conditioning system with 4 way ceiling mounted cassette indoor unit and matching air cooled outdoor unit hermetically sealed scroll compressor condenser and evaporator coil drain pump remote control suitable for 50 degree ambient, installation testing and commissioning of 3 tr split type cassette dx air conditioning system including mounting of indoor and outdoor units vibration isolation pads electrical termination control wiring drain piping nitrogen pressure testing vacuumization refrigerant charging and trial run, supply of centralized remote controller unit of same make as ac units for centralized control and monitoring of all connected vrf indoor and outdoor units complete with all accessories as recommended by manufacturer, installation testing and commissioning of centralized remote control unit for vrf system including all wiring connections configuration of connected indoor and outdoor units testing and commissioning complete as required, supply of 25.4 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 22.2 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 19 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 15.86 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 12.7 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 9.5 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, installation testing and commissioning including vacuumization and nitrogen testing of 25.4 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 22.2 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 19 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 15.86 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 12.7 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 9.5 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, supply of refrigerant y and t joints vrv refnuts joints with insulation as recommended by manufacturer suitable for combination of indoor and outdoor machines for vrf system complete with all accessories, installation testing and commissioning of refrigerant y and t joints vrv refnuts joints with insulation as recommended by manufacturer for vrf system complete with all accessories as required, supply and delivery of 3 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, supply and delivery of 4 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, supply and delivery of 2 core x 1.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, laying of 3 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, laying of 4 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, laying of 2 core x 1.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, supply of pvc condensate drain pipe of suitable size for ac indoor units with supports clamps and insulation as required complete with all accessories as per instructions, installation of pvc condensate drain piping for ac indoor units with supports clamps and all accessories as per site requirement and instructions complete as required, supply of ms table top stands for installing outdoor units vrf outdoor 10 units and dx outdoor 1 unit duly epoxy coated including supply of cowl piece for each outdoor machine as required, installation testing and commissioning of ms table top stands for outdoor units including installation testing and commissioning of cowl piece for each outdoor machine as required, supply and filling of refrigerant gas r410a as required for vrf and dx air conditioning systems complete with all accessories as per manufacturer recommendations and site requirements, supply of 4 core x 10 sq mm copper conductor xlpe insulated pvc sheathed armoured cable 1.1 kv grade conforming to is 7098 part 1 for outdoor unit power supply complete as required, supply of 4 core x 16 sq mm copper conductor xlpe insulated pvc sheathed armoured cable 1.1 kv grade conforming to is 7098 part 1 for outdoor unit power supply complete as required, laying testing and commissioning of 4 core x 10 sq mm copper xlpe armoured cable 1.1 kv grade from odu power distribution board to outdoor units in cable tray trench on wall through shaft with dressing clamping brass glands aluminium lugs and termination complete, laying testing and commissioning of 4 core x 16 sq mm copper xlpe armoured cable 1.1 kv grade from odu power distribution board to outdoor units in cable tray trench on wall through shaft with dressing clamping brass glands aluminium lugs and termination complete, providing fabricating and fixing aluminium anodized partition for air conditioning enclosure using approved aluminium sections with 15 micron anodized finish comprising fixed glazed panels and aluminium framed glazed doors with 5 mm clear float glass door shutters frames floor springs hinges handles locks rubber beading and all accessories, wiring in pvc casing and capping system using 2 x 1.5 sq mm fr pvc insulated copper conductor wire with modular type switches sockets surface mounting plastic frames for light point to be terminated in ceiling rose or batten or angle holder 6 amp 230 volts for led panel light fitting, supply and delivery of recess or surface mounted 2 x 2 luminaire 24 w with 150 lm per watt low glare and cri greater than 90 for hospital ward and corridor lighting as per instructions, installation testing and commissioning of led panel 2 x 2 24 watts to be installed at male and female ward and corridors of hospital as per instructions, supply and delivery of 4 core x 50 sq mm xlpe insulated armoured pvc sheathed heavy duty copper conductor cable 1100 volts grade conforming to is 1554 or is 7098 part 1 of 1988 complete as required, supply and delivery of galvanized iron wire size 8 swg for earthing and cable support as per specifications and instructions, installation charges for fixing and running armoured cables with copper conductors 1100 volts grade on even surfaced walls beams ceilings with appropriate gi saddles and gi spacers with gi wire from central switch chamber to ac power mcbdb at electrical switch room, cable end termination both ends for lv xlpe armoured 4 core x 50 sq mm cable including supply and fixing of double compression cable glands stripping of insulation tinned plated copper lugs for all phases crimping gi nut bolts and washers hdgi 80 micron one set per termination, supply installation testing and commissioning of three pole and neutral distribution board in sheet steel enclosure ip 43 powder coated double door horizontal surface or recess mounting with insulated tinned copper bus bars neutral links din channels earthing terminals 8 way 8 plus 24 way without mcb, supply installation testing and commissioning of four pole isolator 125 amp in suitable enclosure for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of four pole mcb 63 amp for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of four pole mcb 40 amp for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of single pole and neutral consumer unit type distribution board in sheet steel enclosure powder coated single door with acrylic window surface or recess mounting with insulated tinned copper bus bar neutral link din channel 12 way 2 plus 10 way without mcb, supply installation testing and commissioning of double pole mcb 32 amp for hvac indoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of single pole mcb 6 or 10 amp for hvac indoor unit distribution board as per specifications and instructions, supply delivery installation testing and commissioning of switch disconnector fuse unit sfu in sheet steel enclosure suitable for din type hrc fuses with isi mark 100amp tpn to be installed at main switch board in electrical switch room, supply installation testing and commissioning of chemical earth electrode for earthing complete with chemical powder 100 mm dia x 3 m long bore frp chamber 500 x 500 x 200 mm with frp cover earthing rod buried vertically 3 m deep resistance tested with calibrated earth resistance meter, comprehensive annual maintenance contract for air conditioning system first year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system second year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system third year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system fourth year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system fifth year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms


Agency / Dept : mumbai port trust MPT
Tender Value : 0
Due Date : Jun 25, 2026
T18 Ref No : 15602567
live Tender
Location : lucknow , uttar pradesh
Source : GEM Tenders
live Tender

tender for main fire pump , diesel driven pump , jockey pump , terrace pump , control panel , starter , m s pipe , internal hydrant valve , external yard hydrant valve , butterfly valve , sfc of butterfly valve , orifice plate , pitc non return valve , stainless steel y strainer , pitc of stainless steel y strainer , hose pipe , first aid hose reel , short branch pipe , fire brigade connection , foot valve , air vessel , pressure switch , pressure gauge , control valve , hose cabinet , cutting holes , supply of cable , laying of cable , end termination , fire cable , cable tray , earthing , gi strip , gi strip , earth wire , gi pipe, pitc of fire fighting with wet riser system, sh 1 wet riser system main fire pump a supplying, installation, testing and commissioning of electric driven main fire pump conforming to is 12469 2019 suitable for automatic peration and consisting of following complete in all respects as required. b horizontal type multistage centrifugal split casing pump of cast iron body and bronze impeller with stainless steel shaft fire pump capable for delivery of 2280 lpm against atotal head of 70 mtrs approximately while running at 1450 1500 rpm mechanical seal as required bsnl approved make. c suitable hp squirrel cage induction motor tefc synchronous speed 1500 rpm suitable for operation on 415 volts 3 phase 50 hz ac supply with ip 55 protection for enclosure horizontal foot mounted type with class. f insulation conforming to is 12615 2018. d m.s. fabricated common base plate coupling,coupling guard, foundation bolts etc. as required. e suitable cement concrete foundation duly plastered with anti vibration pads note the head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point.the pump room is situated on the underground water tank. 2280 lpm at 70 m head, diesel driven pump a supplying, installation, testing and commissioning of diesel engine driven main fire pump conforming to is 12469 2019 suitable for automatic operation and nsisting of following,complete in all respects, as required.diesel driven pump. b horizontal type, multistage, centrifugal pump of cast of iron body and bronze peller with stainless steel shaft, mechanical seal suitable to delivering 2280 lpm against atoatl head of 70 mtrs approxi as required.c suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.d m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.e suitable cement concrete foundation duly plastered and with anti vibration pads.note the head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point. the pump room is situated on the underground water tank.2280 lpm at 70 m head, jockey pump a supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to is 12469 2019 suitable for automatic operation and consisting of following, complete in all respects as required jockey pump.b horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.c suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 12615 2018. d m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) suitable cement concrete foundation duly plastered and with anti vibration pads.note the pump room is situated on the underground water tank. 180 lpm at 70 m head, supplying, installation, testing and commissioning of electric driven terrace pump conforming to is 12469 2019 suitable for automatic operation and consisting of following,complete in all respects, as required terrace pump b horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.c suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase, 50 hz, ac supply with ip55 class of protection for enclosure, horiziontal foot mounted type with class f insulation, conforming to is-12615 2018. d m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.e suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m head, control panels fabrication supplying installation testing and commissioning of electrical control panel of cubical construction floor mounted type fabricated out of 2mm thick crca , apartmentalised with hinged lockable doors, dust and vermin proof powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper copper strip, having switchgears and accessories, mountings and internal wiring earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurization pump and diesel pump set complete as per cpwd specification and atc attached for main fire pump , jockey pump, diesel pump with system controller as per as per atc attached, supply installation testing and commissioning of fully automatic dol starter for terrace pump terrace pump siutable for operation on 3 phase 415 volt ac supply i/c making inter connection testing etc as requiored at site., sh ii pipes and accessories.providing laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class -ii of is 3589 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per is 10221, refilling the trench etc. of following sizes complete as required. 150 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 50 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 80 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.100 mm dia, providing, laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 150 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 200 mm dia wall thickness 6.3 mm, supplying and fixing single headed internal hydrant valve with instantaneous gunmetal/stainless steel coupling of 63 mm dia with cast iron wheel isi marked conforming to is 5290 type a with blank gunmetal/stainless steel cap and chain as required.single headed gunmetal, supplying and fixing single headed external yard hydrant valve with 1 no. 63 mm dia instantaneous fm gunmetal/stainless steel coupling and cast iron wheel, isi marked, conforming to is 5290 type a with blank gunmetal/stainless steel cap and chain as required. single headed gunmetal, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required . 50mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .80 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .100 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .150 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .200 mm dia, supplying and fixing orifice plate made out of 6 mm thick stainless steel grade 304 with orifice of required size to be fitted between flange and landing valve of external and internal e pressure at the outlet to the level of 3.5 kg/cm2 complete as required., providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 50mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 80 mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 100 mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 150 mm dia., providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange. 80 mm dia, providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange.150 mm dia, providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange. 200 mm dia, supplying and fixing 63 mm dia, 15 m long rrl hose pipe with 63 mm dia male and femalecouplings duly bound with gi wire, rivets etc conforming to is 636 type a as required. gun metal., supplying and fixing first aid hose reel with ms construction spray painted in post office red,conforming to is 884 complete with the following as required.a 20 mm nominal internal dia. water hose thermoplastic textile reinforced type 2 as per is 12585 b 20 mm nominal internal dia gun metal globe valve and nozzle. c drum and brackets for fixing the equipmets on wall. d connections from riser with 25 mm dia stop gun metal valve and m.s. pipe and socket. 30 mtrs, supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to is 903 suitable for instantaneous connection to interconnect hose pipe coupling as required.gun metal., supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd for suitable dia ms pipe connection conforming to is 904 as required. 2 way 100 mm dia m.s. pipe, supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd for suitable dia ms pipe connection conforming to is 904 as required.4 way 150 mm dia m.s. pipe., providing, installation, testing and commissioning of c.i flanged swing type foot valve isi marked of following sizes confirming to is 4038 complete with all acessories complete etc as required.200 mm dia., supplying and fixing air vessel made of 250 mm dia, 8 mm thick ms sheet, 1200 mm in height with airrelease valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required., providing and fixing of pressure switch in m.s. pipe line including connection etc. as required., providing and fixing in position industrial type pressure gauge with gun metal / brass valves complete etc. as required., providing, fixing, testing and commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, ms pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required. 150 mm dia, supplying and fixing of hose cabinet of size 750 mm 600 mm 250 mm made of 2 mm thick ms sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve , 2 nos . 15 mtr. long hose pipe, 1 no branch pipe, mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect , for external hydrant ,as required., cutting holes up to 15cm and 15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1 2 4 1 cement 2 coarse sand graded stone aggregate 20 mm nominal size, including finishing complete so as to make it leak proof., sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988. 4 core 16 sqmm, sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988 . 3.5 core 25 sq. mm, sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988. 3.5 core x 70 sq. mm, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. upto 35 sq. mm clamped with 1mm thick saddle, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. above 35 sq. mm and upto 95 sq. mm clamped with 25 mm and 3mm ms flat clamp., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. above 185 sq. mm and upto 400 sq. mm clamped with 40mm and 3mm ms flat clamp, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required. upto 35 sq. mm clamped with 1mm thick saddle., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required.above 35 sq. mm and upto 95 sq. mm clamped with 25mm and 3mm ms flat clamp., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required.above 185 sq. mm and upto 400 sq. mm clamped with 40mm 3mm ms flat clamp, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.upto 35 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.mm above 35 sq. mm and upto 95 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.above 185 sq. mm and upto 400 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. upto 35 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. above 35 sq. mm and upto 95 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. above 185 sq. mm and upto 400 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 4 core 16 sq. mm size 28mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 25 sq. mm size 28mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 70 sq. mm size 38mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 300 sq. mm size 70mm, supplying and laying of 2core 1.5 sqmm fire alarm armoured cable, 600/1000v rated with annealed copper conductor having xlpe insulation, steel wire armouring and frls/hffr outer sheath complete as required., supplying and installaton following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5 percent, in convenient sections, joined with connectors, suspended from the ceiling with two numbers ms/gi suspenders including base of suitable size ms/gi angle, bolts and nuts, painting suspenders, fastener etc as required. 100 mm wide , 50 mm depth , 1.6 mm thickness, earthing with g.i. earth plate 600 mm length x 600 width and 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required., providing and fixing 25 mm wide and 5 mm thick g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re filling etc. as required., providing and fixing 25 mm wide and 5 mm thick g.i. strip on surface or in recess for connections etc. as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required., providing and fixing following sizes g.i. pipes complete with g.i. fittings including trenching and refilling etc. 80 mm dia nominal bore


Tender Value : 5995340
Due Date : Jun 30, 2026
Published By