Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Fire alarm control panel Tenders List

Latest Fire alarm control panel Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Fire alarm control panel tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Fire alarm control panel tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Fire alarm control panel Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Fire alarm control panel tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Fire alarm control panel Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Fire alarm control panel Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Fire alarm control panel Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Fire alarm control panel tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Fire alarm control panel Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Fire alarm control panel sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Fire alarm control panel tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Fire alarm control panel tenders.

Is EMD mandatory for all Fire alarm control panel tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Fire alarm control panel work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Fire alarm control panel tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Fire alarm control panel Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15916190
new Tender
Location : pune , maharashtra
Source : GEM Tenders
new Tender

corrigendum tender for lv2icvs 2520720467341 cqaicvset049 mod kit vehicular eqpt components , lv2icvs 67565sb4 turn table floor and suspension , lv2icvs 2540720307668 6745594503 pedestalseat , lv2icvs 2510720305788 67558sb135 door hatch vehicle 67558sb135 , lv2icvs nt31c000sb fuel level gauge , lv2icvs 2510720352527 67565sb240 turniable turret , lv2icvs 5340720241403 67558sb146 shieldelectrical connector , lv2icvs 5330018814 kb0596 seal plain , lv2icvs 2815004823 76510sb778 pipe intake , lv2icvs 3020002592 cqaicvset017 gear set worm worm wheel consistng of , lv2icvs 5355001868 67546sb131 cover , lv2icvs 4330720312474 76584sb147 filterfluid 76584sb147 , lv2icvs 252000315476515sb131 final drive vehicular , lv2icvs 3010720201617 67562sb110 coupling shaft rigid , lv2icvs 3010720100852 67562sb11001 couplingshaft flexible , lv2icvs 5310720223678 76512448 spacer ring , lv2icvs 4710720312710 76506sb198 pipe , lv2icvs 4710720312714 76506sb201 piping steel , lv2icvs 4710720312664 76578sb765 pipe assembly , lv2icvs 1025000806 67555sb135 drive unitturret rotation , lv4icvs 1015004464 67554sb126 lifting mechanism , lv2icvs 2930720256637 76503sb178 water radiator , lv2icvs 6220000745 76582sb395 head light , lv2icvs 2520003186 76517sb324 pedal control , lv2icvs 2530004711 cqaicvset020 column steering gear , lv2icvs 76505sb121 gasoline centrifugal pump btsn01 or bts , lv2icvs 5825720276812 azimuth indicator for bmpii onlyp156 , lv3icvs sb2009022 starter s52s sb2009022 , lv2icvs 5930029064 2bk649013sb lever switch throw over switch ppn45 , lv3icvs 2004232br1 articulated connecting rod shell , lv3icvs sb2027004 fuel injection pump assy , lv2icvs 291072030924476505sb291 filterfilter coarse , lv2icvs 76533sb12701 torsion bar with lh twist , lv2icvs 2530720200918 67533sb104 wheel solid rubber tyre , z6r72 17574008 sb1 wiring harness branched alg cable no 2 , lv1r72 thomson cfs control panel , lv1r72 17503002sbb cover hatch , x2r72 ty630973 contactor tkd511 kod , z6r72 5dm667020 converter rotor , x2r72 tu7100361002 contactor tkd111 dod , lv1r72 17245051sb driving coupling with cones , z6r72 miscbk3254110cn electromagnet , k9t72nbc 9999720449510 1190000009 roentgenometer 102 , z7r72 030181b00 w1 communication , z7r72 030160b00 w2 power , z7r72 030165b00 w3 sensor , z7r72 03168b00 w4 controlinterface , z7r72 030171b00 w5 coaxlaser , z7r72 030173b00 w6 display , z7r72 030176b00 w7 msmu , z7r72 041115b00 w8 msm extension , z7r72 042667b00 w9 dvi , z7r72 042668b00 w10 sight , z7r72 056576a01 w3 power splitter , z7r72 60831a01 w6 lbd1 , z7r72 60833a02 w 8 ldb 4 , z7r72 039030a 00 cable tank k1 , z6r72 bk2503057 change over box , z6r72 17674sb mtg of ele component of auto load gear , z6r72 bk468505001 potentiometer pmdm , z6r72 miscbk3259027 compensator , z6r72 2a26sb 1055 switch box 2a26sb 1055 , lv1r72 17217004 electro magnet karden shaft , z6r72 misct72035sbi094dc250 induction sensor , z7r72 israely00257a00 front sectioni length 625 mm , z7r72 israely00258a00 front section2 length 623mm , z7r72 israely00259a00 rear section1 length 829 mm , z7r72 israely0026000 rear section2 length 828 mm , z6r72 bk2968097 replenishing tank traverse , z6r72 bk6450241 hose assy , z6r72 bky1000sb ring assy electrical contact , k9t72nbc 17587077sb2 booster , lv1r72 17265018sb1 frame , z6r72 2a26sb 1049 switch box 2a 26cb 1049 , z6r72 miscbc2958028 actuating cylinder , n1r72 1015003284 jacket assy drg 2a26sb06sb , z6r72 pp28000 device gun setting , z6r72 kp10003g relay assembly group kp1 , lv1r72 17233013sb5 bracket with fuel devices , lv1r72 17217sb mtg of rh hatch door drive , z6r72 2a46sb1020sb firing mechaninsm gun , z1r72 misctypetky3101 contactor , k9 p115000 control indicator p115 , z6r72 miscbd2032005 amplifier , z6r72 bk6659009 coil , z6r72 bs6450126 hose , y3r72 miscptc27418 cable for ptc , z6r72 6110001241kr 1753c000cb distribution box kr 1753s , z6r72 idm608146 ty motor generator 40v ac500hz 8lo 4p , z6r72 384373000000 pumping unit hyd power driven tra1a , z6r72 miscbk2369113 unit gyro , k9t72nbc 4310003693 booster drg no 17587056cb1 , z6r72 2a46sb215cb switch assembly , z6r72 bs6450099 hose mtg set for elev , z6r72 bk2369147 transmitter linear acceleration lat , z6r72 bc4282006 angle limiter 1abc4282006 , lv1r72 sg 101s000sb starter generator sg 101s , z6r72 oyu3602069 micro switch mp12 , z6r72 bod1s000 sb control indicatorbod1s000sb , lv1r72 3040430006960 distributing mechanism left hand, lv2icvs 2520720467341 cqaicvset049 mod kit vehicular eqpt components, lv2icvs 67565sb4 turn table floor and suspension, lv2icvs 2540720307668 6745594503 pedestalseat, lv2icvs 2510720305788 67558sb135 door hatch vehicle 67558sb135, lv2icvs nt31c000sb fuel level gauge, lv2icvs 2510720352527 67565sb240 turniable turret, lv2icvs 534072024140367558sb146 shieldelectrical connector, lv2icvs 5330018814 kb0596 seal plain, lv2icvs 2815004823 76510sb778 pipe intake, lv2icvs 3020002592 cqaicvset017 gear set worm worm wheel consistng of, lv2icvs 535500186867546sb131 cover, lv2icvs 433072031247476584sb147 filterfluid76584sb147, lv2icvs 252000315476515sb131 final drive vehicular, lv2icvs 3010720201617 67562sb110 coupling shaft rigid, lv2icvs 3010720100852 67562sb11001 couplingshaft flexible, lv2icvs 5310720223678 76512448 spacer ring, lv2icvs 4710720312710 76506sb198 pipe, lv2icvs 4710720312714 76506sb201 piping steel, lv2icvs 4710720312664 76578sb765 pipe assembly, lv2icvs 1025000806 67555sb135 drive unitturret rotation, lv4icvs 1015004464 67554sb126 lifting mechanism, lv2icvs 2930720256637 76503sb178 water radiator, lv2icvs 622000074576582sb395 head light, lv2icvs 252000318676517sb324 pedal control, lv2icvs 2530004711cqaicvset020 column steering gear, lv2icvs 76505sb121 gasoline centrifugal pump btsn01 or bts, lv2icvs 5825720276812 azimuth indicator for bmpii onlyp156, lv3icvs sb2009022 starter s52s sb2009022, lv2icvs 5930029064 2bk649013sb lever switch throw over switch ppn45, lv3icvs 2004232br1 articulated connecting rod shell, lv3icvs sb2027004 fuel injection pump assy, lv2icvs 2910720309244 76505sb291 filterfilter coarse, lv2icvs 76533sb12701 torsion bar with lh twist, lv2icvs 253072020091867533sb104 wheel solid rubber tyre, z6r72 17574008 sb1 wiring harness branched alg cable no 2, lv1r72 thomson cfs control panel, lv1r72 17503002sbb cover hatch, x2r72 ty630973 contactor tkd511 kod, z6r72 5dm667020 converter rotor, x2r72 tu7100361002 contactor tkd111 dod, lv1r72 17245051sb driving coupling with cones, z6r72 miscbk3254110cn electromagnet, k9t72nbc 9999720449510 1190000009 roentgenometer 102, z7r72 030181b00 w1 communication, z7r72 030160b00 w2 power, z7r72 030165b00 w3 sensor, z7r72 03168b00 w4 controlinterface, z7r72 030171b00 w5 coaxlaser, z7r72 030173b00 w6 display, z7r72 030176b00 w7 msmu, z7r72 041115b00 w8 msm extension, z7r72 042667b00 w9 dvi, z7r72 042668b00 w10 sight, z7r72 056576a01 w3 power splitter, z7r72 60831a01 w6 lbd1, z7r72 60833a02 w 8 ldb 4, z7r72 039030a 00 cable tank k1, z6r72 bk2503057 change over box, z6r72 17674sb mtg of ele component of auto load gear, z6r72 bk468505001 potentiometer pmdm, z6r72 miscbk3259027 compensator, z6r72 2a26sb 1055 switch box 2a26sb 1055, lv1r72 17217004 electro magnet karden shaft, z6r72 misct72035sbi094dc250 induction sensor, z7r72 israely00257a00 front sectioni length 625 mm, z7r72 israely00258a00 front section2 length 623mm, z7r72 israely00259a00 rear section1 length 829 mm, z7r72 israely0026000 rear section2 length 828 mm, z6r72 bk2968097 replenishing tank traverse, z6r72 bk6450241 hose assy, z6r72 bky1000sb ring assy electrical contact, k9t72nbc 17587077sb2 booster, lv1r72 17265018sb1 frame, z6r72 2a26sb 1049 switch box 2a 26cb 1049, z6r72 miscbc2958028 actuating cylinder, n1r72 1015003284 jacket assy drg 2a26sb06sb, z6r72 pp28000 device gun setting, z6r72 kp10003g relay assembly group kp1, lv1r72 17233013sb5 bracket with fuel devices, lv1r72 17217sb mtg of rh hatch door drive, z6r72 2a46sb1020sb firing mechaninsm gun, z1r72 misctypetky3101 contactor, k9 p115000 control indicator p115, z6r72 miscbd2032005 amplifier, z6r72 bk6659009 coil, z6r72 bs6450126 hose, y3r72 miscptc27418 cable for ptc, z6r72 6110001241kr 1753c000cb distribution box kr 1753s, z6r72 idm608146 ty motor generator 40v ac500hz 8lo 4p, z6r72 384373000000 pumping unit hyd power driven tra1a, z6r72 miscbk2369113 unit gyro, k9t72nbc 4310003693 booster drg no 17587056cb1, z6r72 2a46sb215cb switch assembly, z6r72 bs6450099 hose mtg set for elev, z6r72 bk2369147 transmitter linear acceleration lat, z6r72 bc4282006 angle limiter 1abc4282006, lv1r72 sg 101s000sb starter generator sg 101s, z6r72 oyu3602069 micro switch mp12, z6r72 bod1s000 sb control indicatorbod1s000sb, lv1r72 3040430006960 distributing mechanism left hand, lv1r72 mp5178020sb tachometer te4v electric, lv1r72 17260161sb1 cylinder with valve, lv1r72 17250004sbb disc with hub, lv1r72 mp2320010sb tachometer sending unit d4, lv3r72 32930 gasket drg no 32930, lv1r90 sg181stu starter generator sg181s, z1r90 misc18873007sb3 cable no 1p, z6r90 bv29000 block bv 29, y3r90 y318873008sb4 cable no 2p running from bv34 to 173pm, k9t90sgo27 tg485301202 cii cable no 1, k9t90sgo27 tr48530143 cii cable no 2, n1r90 1015012784 thermal jacket, v5 rus18794004 sb201 bh elevation drive assy, z7 rusbl2320040 gun postion sending unit, z6r90 bel175001460011 solid state converter t90, z6r90 9s5171s00000tu automatic control unit 9s5171s, n1r90 1015012757 recuperator assy 2a46msb07sb, k9 b13000tu automatic control unit b13, z6r90 bs2958032 actuating cylinder, z6r90 bs23690164 rate gyro unit, z6r90 pb2950008 unit hyd booster, z7 rusaschye5103112 correction block, z6r90 bs6644148sb wiring harness branched cable no1 st, z6r90 6150720342856 wiring harness branched, n1r90 1010013342 inner slip cover 17220021sb1sb, z6r90 5995020624 wiring harness a l3500 mm, z6r90 18870042sb oh 287 cable no 2, z7 rusaschye5422005 switching unit, z6r90 bas6a000sb alarm signaling unit, lv1r90 18832096sb oil cooler, z1r90 18873014sb11 cable no 8p running from bv 34 to bv 35, k9t90sgo27 tg485337101 cable no 3, lv1r90 2930720540060 rh water radiator 18831123sb, z6r90 kp11c000tu relay unit kp11s, lv1r90 17255010sb1 track


Agency / Dept : indian army
Tender Value : 0
Due Date : Jun 26, 2026
T18 Ref No : 15602515
live Tender
Location : mumbai , maharashtra
Source : GEM Tenders
live Tender

corrigendum tender for optional , making of ht cable transition joint pilc to xlpe optional , excavation of ht cable trench in soft soil or asphalt , ht cable trench excavation in concrete road optional , laying of ht xlpe cable 3cx240sqmm in excavated trench , laying of ht cable in rcc pipe or existing duct , supply of 200mm dia rcc pipe np2 class with collars , laying of rcc pipe and fixing of collars , supply of lt xlpe cable 3.5cx400sqmm to fp 6a , supply of lt xlpe cable 3.5cx400sqmm to fp 11 , supply of lt xlpe cable 3.5cx300sqmm to fp 1a , supply of lt xlpe cable 3.5cx300sqmm to fp 3 , supply of lt xlpe cable 3.5cx300sqmm to fp 4 , supply of lt xlpe cable 3.5cx300sqmm to fp 5 , supply of lt xlpe cable 3.5cx300sqmm to fp 6b , supply of lt xlpe cable 3.5cx300sqmm to fp 6c , lt cable trench excavation in asphalt paver area , laying of lt cable 3.5cx300 or 400sqmm in excavated trench , laying lt cable 3.5cx300 or 400sqmm in pipe or duct , supply of lt xlpe cable 3.5cx70sqmm to old cme building , excavation of lt cable trench for 70sqmm cable , laying of lt cable 3.5cx70sqmm in excavated trench , laying of lt cable 3.5cx70sqmm in rcc pipe or duct , cable termination material for 3.5cx70sqmm lt cable , cable termination installation for 3.5cx70sqmm lt cable , cable termination material for 3.5cx300sqmm lt cable , cable termination installation for 3.5cx300sqmm lt cable , cable termination material for 3.5cx400sqmm lt cable , cable termination installation for 3.5cx400sqmm lt cable , e-house foundation civil work , e-house shed supply and installation , rubble packing 250mm thick for cable trench reinstatement , stone metal 40-90mm layer for trench reinstatement , water bound macadam wbm layer for trench reinstatement , m10 grade rmc concrete levelling course , m40 grade rmc concrete road pavement , interlocking paver blocks 100mm thick , asphaltic macadam bitumen grade 60 70 regulating course , asphaltic concrete wearing course bitumen grade 60 70 , transporting surplus excavated material outside mbpa estate , dismantling of existing workshop substation, shifting of secondary substation at workshop to frere basin compound, supply of prefabricated containerized substation e-house having ip54 enclosure with 2 hr fire rated thermal insulation sandwich panel suitable for accommodating ht lt switchgear panel transformers battery bank battery charger and apfc panels as per technical specification, installation of the prefabricated containerized substation e-house at site including all necessary activities for proper placement and fixing as per oem drawings and instructions of engineer in charge, supply of 6.6kv eco-friendly indoor type green gis vcb switchgear panel with maximum system voltage 12kv 500mva rupturing capacity comprising 2 incomer 1 buscoupler 2 outgoing feeders 2 transformer feeders and 2 set bus pt as per technical specification, installation testing and commissioning of the 6.6kv ht gis vcb switchgear panel inside the e-house as per technical specification and in the presence of mbpa representative, supply of 24v dc smf-vrla battery bank of suitable load rating for ht and lt switchgear panels with minimum 1 hour backup including battery stand inter-battery wiring terminal connectors accessories and bhms as per technical specification, installation testing and commissioning of 24v dc smf-vrla battery bank inside the e-house as per technical specification and in the presence of mbpa representative, supply of float and float-cum boost charger suitable for battery bank including incoming and outgoing cables wires connection in ht switchgear and control panels with full wave rectification for 440v 3 phase 4 wire 50hz ac input supply as per technical specification, installation testing and commissioning of float and float cum boost charger inside the e-house as per technical specification and in the presence of mbpa representative, supply of iec 61439 compliant oem lt panel with tpn 2000a copper busbar 50ka 1 sec stc comprising 2 incomer acb 1 buscoupler acb 10 outgoing acb 5 mccb 400a 2 mccb 250a 2 mccb for apfc and 5 mcb outgoings as per technical specification, installation testing and commissioning of lt switchgear panel inside the e-house as per technical specification and in the presence of mbpa representative, supply of 1000 kva 6.6kv to 0.433kv dyn-11 copper wound an cooling cast resin dry type indoor transformer ip00 with off load tap links wti scanner class f insulation ht and lt cable boxes and standard accessories as per ecbc 2021 2 sets, installation testing and commissioning of 1000kva dry type transformer at site inside the e-house as per technical specification and in the presence of mbpa representative 2 numbers, supply of wall mounted smart local monitoring hmi box with windows 10 iot intel core i5 processor 8gb ram 64gb memory 15.6 inch touch screen iec 61850 client master application software for complete substation monitoring as per technical specification, installation testing and commissioning of smart local monitoring hmi system including integration with protection relays via iec 61850 ed 2 lan as per technical specification and in the presence of mbpa representative, supply of cubicle type free standing floor mounted apfc panels of 200 kvar capacity conforming to iec 61439 with mccb incomer capacitor banks detuned reactors apfc relay and all accessories as per technical specification 2 sets, installation testing and commissioning of apfc panels inside the e-house as per technical specification and in the presence of mbpa representative 2 numbers, supply of fire detection and alarm system comprising fire alarm control panel multi-area detection module multi sensor heat and smoke detectors break glass manual call points indoor and outdoor alarm hooters with ac shutdown interlock as per technical specification, installation testing and commissioning of fire detection and alarm system as per technical specification and in the presence of mbpa representative, supply of fire extinguishers as per is 3034-1993 of suitable capacity and type for the e-house substation application complete with all accessories and mountings, installation of fire extinguishers at designated locations inside the e-house as per directions of engineer in charge, supply of minimum 2 nos 2 ton copper coil inverter split air conditioners of heavy duty industrial type along with ac controller for e-house control room as per technical specification similar to o general hitachi samsung or equivalent, installation testing and commissioning of split air conditioners and ac controller inside the e-house as per technical specification and in the presence of mbpa representative, supply of suitable type touch proof termination kits as required for ht and lt power and control cables to and within the container equipment as per technical specification, installation testing and commissioning of ht and lt touch proof termination kits inside the e-house as per technical specification and in the presence of mbpa representative, supply of 600va ups system along with smf-vrla battery conforming to jisc-8702 pt 1 2 and 3 with single phase 230v ac 50hz output for e-house emergency illumination complete with all accessories, installation testing and commissioning of ups system with battery inside the e-house as per technical specification and in the presence of mbpa representative, supply and making of chemical earthing pit using chemical earth electrode with minimum 25 kg chemical powder cement concrete chamber 500x500x200mm ci rcc cover earthing rod 17.2mm dia 3 mtr long copper bonded 250 microns as per is 3043-2018 and iec 62561 16 numbers, supply and laying of galvanized ms earthing flat 50mm x 6mm for ht lt apfc battery charger and transformer body earthing of substation equipment as per technical specification, supply and laying of copper earthing flat 50mm x 6mm for transformer neutral earthing of the substation as per technical specification, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to tank bunder substation, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to pandv dock substation, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to central substation css, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to ro-ro pax terminal substation, tracing out existing buried 6.6kv ht cable laid feeder identification of existing feeder cable puncture and cutting in presence of mbpa representative contractor to arrange all necessary testing kits required for the same, supply of straight through joint for ht cable 3c x 240 sqmm xlpe insulated armoured aluminium conductor 11kv e 6.6kv ue grade using heat shrinkable raychem make jointing kit with ferrules tape etc complete in all respect, making of ht cable 6.6kv ue 11kv e grade straight through jointing work for cable 3c x 240 sqmm xlpe to xlpe in the presence of mbpa representative, carrying out necessary high potential test before and after making joints using calibrated testing equipment with complete test reports in the presence of mbpa representative, carrying out necessary phase sequence test using calibrated testing equipment with complete test reports and commissioning the cable in all respect in the presence of mbpa representative, supply of straight through transition joint for ht cable 3c x 240 sqmm xlpe insulated armoured aluminium conductor 11kv e grade using heat shrinkable raychem make jointing kit with ferrules tape etc complete in all respect optional, making of ht cable 6.6kv ue 11kv e grade straight through transition jointing work for cable 3c x 240 sqmm pilc to xlpe in the presence of mbpa representative optional, excavating suitable trench for ht cable in any type of soft soil or asphalt including cleaning cable trenches tentative size 1.0 mtr w x 1.2 mtr d x 300 mtr l, excavating suitable trench for ht cable in concrete or stone road including cleaning cable trenches tentative size 1.0 mtr w x 1.2 mtr d x 85 mtr l optional, laying of incoming and outgoing 3c x 240 sqmm xlpe aluminium armoured cable in excavated cable trench at depth 1200mm including cleaning dressing providing screened sand and rcc tiles engraved mbpa 6600 volts as per drawing, laying of ht cable in rcc pipe hdpe pipe existing duct or cc trench including all necessary activities as per specification, supply of rcc pipe 200mm dia np2 class of standard length with collars including cement concreting closing ends of pipes after passing cable across road culverts drains etc, laying of rcc pipe 200mm dia np2 class and fixing of collars at site including all necessary activities as per specification, supply and delivery of 3.5c x 400 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6a, supply and delivery of 3.5c x 400 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 11, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 1a, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 3, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 4, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 5, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6b, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6c, excavating suitable trench for lt cable in asphalt soil or paver block footpath with curb stone including cleaning cable trenches tentative size 0.8 mtr w x 0.9 mtr d x 700 mtr l, laying of incoming and outgoing 3.5c x 300 or 400 sqmm lt xlpe armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification, laying of incoming and outgoing 3.5c x 300 or 400 sqmm lt xlpe armoured cables in rcc pipe hdpe pipe existing duct cc trench or saddling on wall as per specification, supply and delivery of 3.5c x 70 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable for outgoing to old cme building sbi from fp no 4 nirman bhavan, excavating suitable trench for lt cable in asphalt soil or paver block footpath with cup stone including cleaning cable trenches tentative size 0.8 mtr w x 0.9 mtr d x 150 mtr l, laying of incoming and outgoing 3.5c x 70 sqmm lt xlpe armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification, laying of incoming and outgoing 3.5c x 70 sqmm lt xlpe armoured cables in rcc pipe hdpe pipe existing duct cc trench or saddling on wall as per specification, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 70 sqmm xlpe pvc cable 1100 volts grade 2 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 70 sqmm xlpe pvc cable 1100 volts grade 2 ends, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 300 sqmm xlpe pvc cable 1100 volts grade 6 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 300 sqmm xlpe pvc cable 1100 volts grade 6 ends, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 400 sqmm xlpe pvc cable 1100 volts grade 2 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 400 sqmm xlpe pvc cable 1100 volts grade 2 ends, suitable quantity dimensions and grade of concrete for e-house foundation columns including soil excavation as per oem design drawings and structural design approved by bmc registered structural engineer, supply and installation of e-house shed including foundation columns i-beams angles and covering sheets as per design drawings approved by bmc registered structural engineer, providing and laying approved quality rubble packing 250mm thick hand set including filling interstices with stone chips grit stone dust watering and consolidation as specified and as directed, providing and laying 40mm to 90mm size stone metal of approved quality to required thickness in layers not exceeding 120mm consolidated with roller including filling interstices with grit stone dust sand as directed, providing and laying water bound macadam wbm layer 100mm consolidated thickness with 40 to 63mm metal consolidated with roller including watering blending with sand stone dust grit brick powder as specified, providing and laying m10 grade ready mix cement concrete from approved rmc plant in levelling course of required thickness including transit mixer form work plate vibrator curing etc as specified, providing and laying m40 grade ready mix cement concrete from approved rmc plant in road pavement bays including form work power driven screed plate and needle vibrators brooming vatas bitumen curing as specified, providing and laying approved coloured cement concrete interlocking paver blocks 100mm thick with sand bedding minimum 50mm and filling joints with fine sand as directed, providing and laying hot pre-mixed asphaltic macadam bitumen grade 60 70 with anti-stripping agent 0.5 percent by weight in regulating course and rolling with 8 to 10 tonne road roller as specified payment by weight, providing and laying hot pre-mixed asphaltic concrete wearing course bitumen grade 60 70 with anti-stripping agent 0.50 percent by weight of required thickness and rolling with 8 to 10 tonne road roller as specified payment by weight, transporting surplus excavated material stones debris kutchra from mbpa estate including loading and taking away materials anywhere outside mbpa estate as directed, dismantling of existing ht lt panel transformers apfc panel battery charger and bank cables and cable terminations of existing workshop substation and shifting removed electrical equipment to mbpa store as per instructions of engineer


Agency / Dept : mumbai port trust MPT
Tender Value : 92399995
Due Date : Jun 23, 2026
T18 Ref No : 15795452
live Tender
Location : new delhi , delhi
Source : GEM Tenders
live Tender

tender for digital signage podium ultra plus with integrated pa system , 86 inch interactive flat panel display , online ups 6 kva , smf battery 12v 65ah , open rack with installation , cctv surveillance system with installation , biometric attendance system with em lock , 1.5 ton hot and cold split ac , smart 360 degree air purifier , 1 loop addressable fire alarm panel , addressable multi-criteria smoke and heat detector , addressable manual call point , addressable sounder cum strobe unit , 2c x 1.5 sq.mm frls armoured copper cable , 25 mm heavy duty pvc conduit system , abc type fire extinguisher 2 kg, supply installation testing and commissioning smart conference room setup av system power backup fire safety access control, digital signage podium with inbuilt pa system, 02 wireless microphones (01 handheld & 01 lapel/headset), 02 gooseneck microphones, 32-inch signage display and 21.5-inch touch monitor, 86-inch 4k uhd interactive display with built-in android os, 8gb ram, 128gb storage and up to 40-point multi-touch capability., 6 kva online ups suitable for continuous power backup applications, sealed maintenance free (smf) 12v 65ah battery suitable for ups applications, open rack with complete installation, cabling and linking accessories, complete cctv surveillance system including cameras, accessories, cabling and installation, biometric access control system (essl mb 20 plus 1d) with em lock and installation., 1.5 ton split air conditioner with hot & cold function, energy rating 3/5 star, 360-degree smart air purifier for indoor air quality improvement, 1-loop addressable fire alarm control panel for fire detection system, plug-in type addressable multi-criteria photoelectric smoke and heat detector, recess/surface mounted dust and vermin proof addressable manual call point with unbreakable glass, sounder cum strobe providing 80 dba audible alarm and 115 cd visual flashing at 1 hz for evacuation, copper conductor pvc insulated frls sheathed armoured multistrand cable including laying, termination and tagging., heavy duty pvc conduit with accessories including bends, junction boxes, gi fish wire and installation, 2 kg abc type fire extinguisher suitable for electrical and general fire safety applications


Agency / Dept :
Tender Value : 0
Due Date : Jun 27, 2026
T18 Ref No : 15602567
live Tender
Location : lucknow , uttar pradesh
Source : GEM Tenders
live Tender

tender for main fire pump , diesel driven pump , jockey pump , terrace pump , control panel , starter , m s pipe , internal hydrant valve , external yard hydrant valve , butterfly valve , sfc of butterfly valve , orifice plate , pitc non return valve , stainless steel y strainer , pitc of stainless steel y strainer , hose pipe , first aid hose reel , short branch pipe , fire brigade connection , foot valve , air vessel , pressure switch , pressure gauge , control valve , hose cabinet , cutting holes , supply of cable , laying of cable , end termination , fire cable , cable tray , earthing , gi strip , gi strip , earth wire , gi pipe, pitc of fire fighting with wet riser system, sh 1 wet riser system main fire pump a supplying, installation, testing and commissioning of electric driven main fire pump conforming to is 12469 2019 suitable for automatic peration and consisting of following complete in all respects as required. b horizontal type multistage centrifugal split casing pump of cast iron body and bronze impeller with stainless steel shaft fire pump capable for delivery of 2280 lpm against atotal head of 70 mtrs approximately while running at 1450 1500 rpm mechanical seal as required bsnl approved make. c suitable hp squirrel cage induction motor tefc synchronous speed 1500 rpm suitable for operation on 415 volts 3 phase 50 hz ac supply with ip 55 protection for enclosure horizontal foot mounted type with class. f insulation conforming to is 12615 2018. d m.s. fabricated common base plate coupling,coupling guard, foundation bolts etc. as required. e suitable cement concrete foundation duly plastered with anti vibration pads note the head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point.the pump room is situated on the underground water tank. 2280 lpm at 70 m head, diesel driven pump a supplying, installation, testing and commissioning of diesel engine driven main fire pump conforming to is 12469 2019 suitable for automatic operation and nsisting of following,complete in all respects, as required.diesel driven pump. b horizontal type, multistage, centrifugal pump of cast of iron body and bronze peller with stainless steel shaft, mechanical seal suitable to delivering 2280 lpm against atoatl head of 70 mtrs approxi as required.c suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.d m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.e suitable cement concrete foundation duly plastered and with anti vibration pads.note the head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point. the pump room is situated on the underground water tank.2280 lpm at 70 m head, jockey pump a supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to is 12469 2019 suitable for automatic operation and consisting of following, complete in all respects as required jockey pump.b horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.c suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 12615 2018. d m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) suitable cement concrete foundation duly plastered and with anti vibration pads.note the pump room is situated on the underground water tank. 180 lpm at 70 m head, supplying, installation, testing and commissioning of electric driven terrace pump conforming to is 12469 2019 suitable for automatic operation and consisting of following,complete in all respects, as required terrace pump b horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.c suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase, 50 hz, ac supply with ip55 class of protection for enclosure, horiziontal foot mounted type with class f insulation, conforming to is-12615 2018. d m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.e suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m head, control panels fabrication supplying installation testing and commissioning of electrical control panel of cubical construction floor mounted type fabricated out of 2mm thick crca , apartmentalised with hinged lockable doors, dust and vermin proof powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper copper strip, having switchgears and accessories, mountings and internal wiring earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurization pump and diesel pump set complete as per cpwd specification and atc attached for main fire pump , jockey pump, diesel pump with system controller as per as per atc attached, supply installation testing and commissioning of fully automatic dol starter for terrace pump terrace pump siutable for operation on 3 phase 415 volt ac supply i/c making inter connection testing etc as requiored at site., sh ii pipes and accessories.providing laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class -ii of is 3589 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per is 10221, refilling the trench etc. of following sizes complete as required. 150 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 50 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 80 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.100 mm dia, providing, laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 150 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 200 mm dia wall thickness 6.3 mm, supplying and fixing single headed internal hydrant valve with instantaneous gunmetal/stainless steel coupling of 63 mm dia with cast iron wheel isi marked conforming to is 5290 type a with blank gunmetal/stainless steel cap and chain as required.single headed gunmetal, supplying and fixing single headed external yard hydrant valve with 1 no. 63 mm dia instantaneous fm gunmetal/stainless steel coupling and cast iron wheel, isi marked, conforming to is 5290 type a with blank gunmetal/stainless steel cap and chain as required. single headed gunmetal, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required . 50mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .80 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .100 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .150 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .200 mm dia, supplying and fixing orifice plate made out of 6 mm thick stainless steel grade 304 with orifice of required size to be fitted between flange and landing valve of external and internal e pressure at the outlet to the level of 3.5 kg/cm2 complete as required., providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 50mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 80 mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 100 mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 150 mm dia., providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange. 80 mm dia, providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange.150 mm dia, providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange. 200 mm dia, supplying and fixing 63 mm dia, 15 m long rrl hose pipe with 63 mm dia male and femalecouplings duly bound with gi wire, rivets etc conforming to is 636 type a as required. gun metal., supplying and fixing first aid hose reel with ms construction spray painted in post office red,conforming to is 884 complete with the following as required.a 20 mm nominal internal dia. water hose thermoplastic textile reinforced type 2 as per is 12585 b 20 mm nominal internal dia gun metal globe valve and nozzle. c drum and brackets for fixing the equipmets on wall. d connections from riser with 25 mm dia stop gun metal valve and m.s. pipe and socket. 30 mtrs, supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to is 903 suitable for instantaneous connection to interconnect hose pipe coupling as required.gun metal., supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd for suitable dia ms pipe connection conforming to is 904 as required. 2 way 100 mm dia m.s. pipe, supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd for suitable dia ms pipe connection conforming to is 904 as required.4 way 150 mm dia m.s. pipe., providing, installation, testing and commissioning of c.i flanged swing type foot valve isi marked of following sizes confirming to is 4038 complete with all acessories complete etc as required.200 mm dia., supplying and fixing air vessel made of 250 mm dia, 8 mm thick ms sheet, 1200 mm in height with airrelease valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required., providing and fixing of pressure switch in m.s. pipe line including connection etc. as required., providing and fixing in position industrial type pressure gauge with gun metal / brass valves complete etc. as required., providing, fixing, testing and commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, ms pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required. 150 mm dia, supplying and fixing of hose cabinet of size 750 mm 600 mm 250 mm made of 2 mm thick ms sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve , 2 nos . 15 mtr. long hose pipe, 1 no branch pipe, mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect , for external hydrant ,as required., cutting holes up to 15cm and 15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1 2 4 1 cement 2 coarse sand graded stone aggregate 20 mm nominal size, including finishing complete so as to make it leak proof., sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988. 4 core 16 sqmm, sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988 . 3.5 core 25 sq. mm, sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988. 3.5 core x 70 sq. mm, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. upto 35 sq. mm clamped with 1mm thick saddle, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. above 35 sq. mm and upto 95 sq. mm clamped with 25 mm and 3mm ms flat clamp., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. above 185 sq. mm and upto 400 sq. mm clamped with 40mm and 3mm ms flat clamp, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required. upto 35 sq. mm clamped with 1mm thick saddle., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required.above 35 sq. mm and upto 95 sq. mm clamped with 25mm and 3mm ms flat clamp., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required.above 185 sq. mm and upto 400 sq. mm clamped with 40mm 3mm ms flat clamp, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.upto 35 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.mm above 35 sq. mm and upto 95 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.above 185 sq. mm and upto 400 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. upto 35 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. above 35 sq. mm and upto 95 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. above 185 sq. mm and upto 400 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 4 core 16 sq. mm size 28mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 25 sq. mm size 28mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 70 sq. mm size 38mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 300 sq. mm size 70mm, supplying and laying of 2core 1.5 sqmm fire alarm armoured cable, 600/1000v rated with annealed copper conductor having xlpe insulation, steel wire armouring and frls/hffr outer sheath complete as required., supplying and installaton following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5 percent, in convenient sections, joined with connectors, suspended from the ceiling with two numbers ms/gi suspenders including base of suitable size ms/gi angle, bolts and nuts, painting suspenders, fastener etc as required. 100 mm wide , 50 mm depth , 1.6 mm thickness, earthing with g.i. earth plate 600 mm length x 600 width and 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required., providing and fixing 25 mm wide and 5 mm thick g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re filling etc. as required., providing and fixing 25 mm wide and 5 mm thick g.i. strip on surface or in recess for connections etc. as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required., providing and fixing following sizes g.i. pipes complete with g.i. fittings including trenching and refilling etc. 80 mm dia nominal bore


Tender Value : 5995340
Due Date : Jun 30, 2026
Published By

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to fire alarm control panel. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the fire alarm control panel sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the fire alarm control panel Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in fire alarm control panel, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our fire alarm control panel Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For fire alarm control panel Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for fire alarm control panel.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for fire alarm control panel depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For fire alarm control panel Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for fire alarm control panel bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of fire alarm control panel. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for fire alarm control panel, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to fire alarm control panel, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in fire alarm control panel?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based fire alarm control panel tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for fire alarm control panel?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for fire alarm control panel, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for fire alarm control panel is declared L1 and is generally awarded the contract