Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Cable termination kit suitable Tenders List

Latest Cable termination kit suitable Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Cable termination kit suitable tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Cable termination kit suitable tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Cable termination kit suitable Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Cable termination kit suitable tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Cable termination kit suitable Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Cable termination kit suitable Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Cable termination kit suitable Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Cable termination kit suitable tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Cable termination kit suitable Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Cable termination kit suitable sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Cable termination kit suitable tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Cable termination kit suitable tenders.

Is EMD mandatory for all Cable termination kit suitable tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Cable termination kit suitable work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Cable termination kit suitable tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Cable termination kit suitable Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15425927
new Tender
Source : GEM Tenders
new Tender

tender for supply part for retrofitting of lt panel by supply and installation , service part for retrofitting of lt panel by supply and installation , supply of main incoming lt power distribution panels slipway , installation , replace, test and commissioning of main incoming lt power distribution panels slipway , supply of welding and lighting panels slipway , installation , replace, test and commissioning of welding and lighting panels slipway , supply of 3.5c x 400 sq.mm aluminum cable from substation-02 to slipway , laying, fixing, testing and commissioning of 3.5c x 400 sq.mm aluminum cable from substation-02 to slipway , supply of 3.5cx 185 sq.mm aluminum cable from slipway-2 and 3 main incoming panels to welding and lighting panels , laying, fixing, testing and commissioning of 3.5cx 185 sq.mm aluminum cable from slipway-2 and 3 main incoming panels to welding and lighting panels , supply and fitment of suitable end termination kits - straight through joints kits of required quantity to all the incoming and outgoing cables at both ends of slipway-02, slipway-03, substations, etc , providing earth pits with 75mm ci pipe as is standards , supply and laying of gi flat 50 x10 mm necessary joints with nut and bolts from earth pit to panel boards , repair and excavation of cable trench of 75mm thick up to 90cm depth , fixing of perforated cable tray on slipways 02 and 03 and securing of cables with metal ties and capping and casing to be provided , foundation for all lt panels i.e. steel foundations with concrete pedestal for panels all incoming and welding and lighting panels, refurbishment and replacement of electrical panels, supply part for retrofitting of lt panel by supply & installation of 1250a,50ka,edo acb along with suitable bus bar rating at north & ss2 lt panels as per technical specification & sow., service part for retrofitting of lt panel by supply & installation of 1250a,50ka,edo acb along with suitable bus bar rating at north & ss2 lt panels as per technical specification & sow., supply of main incoming lt power distribution panels slipway-2&3 as per technical spec & sow., installation , replace, test and commissioning of main incoming lt power distribution panels slipway-2&3 (4nos.) as per technical spec & sow., supply of welding and lighting panels slipway-2&3 (17nos) as per technical spec & sow., installation , replace, test and commissioning of welding and lighting panels slipway-2&3 (17nos) as per technical spec & sow., supply of 3.5c x 400 sq.mm aluminum cable (from substation-02 to slipway-2&3 main incoming panels) as per technical specification & sow., laying, fixing, testing and commissioning of 3.5c x 400 sq.mm aluminum cable (from substation-02 to slipway-2&3 main incoming panels) as per technical specification & sow., supply of 3.5cx 185 sq.mm aluminum cable (from slipway-2&3 main incoming panels to welding and lighting panels) as per technical specification & sow., laying, fixing, testing and commissioning of 3.5cx 185 sq.mm aluminum cable (from slipway-2&3 main incoming panels to welding and lighting panels) as per technical specification & sow., supply and fitment of suitable end termination kits / straight through joints kits of required quantity to all the incoming & outgoing cables at both ends of slipway-02, slipway-03, substations, etc., as per tech spec. & sow, providing earth pits with 75mm ci pipe as is standards as per technical specification & sow., supply and laying of gi flat 50 x10 mm necessary joints with nut and bolts from earth pit to panel boards as per technical specification & sow, repair and excavation of cable trench (of 75mm thick) up to 90cm depth as per technical specification & sow., fixing of perforated cable tray on slipways 02 & 03 and securing of cables with metal ties and capping & casing to be provided as per technical specification & sow., foundation for all lt panels i.e. steel foundations with concrete pedestal for panels (all incoming and welding & lighting panels as per technical specification & sow.


Tender Value : 0
Due Date : May 29, 2026
T18 Ref No : 15674893
new Tender
Location : hyderabad , telangana
Source : GEM Tenders
new Tender

tender for xlpe cable cable joint kit suitable for cables up to and including 33 kv (v2) (q3) , sluice valve for water works purposes (50 to 1200 mm size) (v2) as per is 14846 (q3) , rotational moulded polyethylene water storage tanks (v3) conforming to is 12701 (q3) , on-load changeover switch with four pole 100a , on-load changeover switch with four pole 200a , 3p neutral switch fuse unit 32 amps , 3p neutral switch fuse unit 100 amps , mccb box , water tank , xlpe cable witrh valid bis license , dwc hdpe pipe for xlpe cable 40mm , dwc hdpe pipe for xlpe cable 50mm , dwc hdpe pipe for xlpe cable 100mm , dwc hdpe pipe for xlpe cable 150mm , high bay light having valid bis license , bulk head having valid bis license , garden kight having valid bis license , 60w circular led post-top , garden light pole , uv stabilized pure polyester coating led garden light pole base , spike light , spot light, xlpe cable, on-load changeover switch with four pole 100a rating in ss encloser conforming to is 13947 (part-3) iec 60947-3, on-load changeover switch with four pole 200a rating in ss encloser conforming to is 13947 (part-3) iec 60947-3, 3p neutral switch fuse unit 32 amps, 3p neutral switch fuse unit 100 amps, single door crca mccb metal powder coated box, fp 100 amp three phase ik 08 protection conforming to iec 61439-3, single door crca mccb metal powder coated box, fp 100 amp three phase ik 08 protection conforming to iec 61439-3, water storage tank pvc 500 ltrs 3-layer white colour virgin grade, isi marked 02 core, 10 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with standed aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 02 core, 16 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 3 core, 04 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 unarmoured with galvanised round steel wire or steel strip as per is 3975 and with stranded aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 3.5 core, 25 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with stranded aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 3.5 core, 35 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 3.5 core, 50 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 3.5 core, 70 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 3.5 core, 95 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 3.5 core, 120 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with standed aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 3.5 core, 150 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 3.5 core, 185 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with standed aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 3.5 core, 240 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with standed aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 3.5 core, 400 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with standed aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 4 core, 6 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with stranded aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 3 core, 95 sqmm high tension cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with stranded aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-ii) working voltages 3.3 kv up to 11kv earthed., isi marked 3 core, 120 sqmm high tention cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with stranded aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-ii) working voltages 3.3 kv up to 11kv earthed., isi marked 4 core, 10 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with stranded aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 4 core, 16 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with stranded aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), isi marked 4 core, 25 sqmm cross linked polyethelene insulated, pvc outer sheathed as per is 5831 armoured with galvanised round steel wire or steel strip as per is 3975 and with stranded aluminium conductor as per is 8130 suitable for rated voltage at 1100 volts grade and conforming to is 7098(part-1), dwc hdpe pipe (double wall corrugated, isi marked) for underground lt xlpe cable protection, including all accessories (couplers, bends, sockets, snap-fit joints), as per is 16205 (part 24) 2017, type 450n or sn8 class. size 40 mm, dwc hdpe pipe (double wall corrugated, isi marked) for underground lt xlpe cable protection, including all accessories (couplers, bends, sockets, snap-fit joints), as per is 16205 (part 24) 2017, type 450n or sn8 class. size 50 mm, dwc hdpe pipe (double wall corrugated, isi marked) for underground lt xlpe cable protection, including all accessories (couplers, bends, sockets, snap-fit joints), as per is 16205 (part 24) 2017, type 450n or sn8 class, size 100mm, dwc hdpe pipe (double wall corrugated, isi marked) for underground lt xlpe cable protection, including all accessories (couplers, bends, sockets, snap-fit joints), as per is 16205 (part 24) 2017, type 450n or sn8 class, size 150mm, water storage tank pvc 1000 ltrs 3-layer white colour virgin grade, high bay module led light fitting-input 90w with surge protection and cct - 3000k, having lamp housing or heat sink shall be made up of stainless steel or aluminimum or any other metal made from either extruded or pressure die casted or any manufacturing process to withstand lifetime performance and having high thermal conductivity material emitting luminous flux of 10000, input voltage220- 240v ac , 50 hz, power factor greater than0.9 with wall/clamp based mounting arrangements, high bay module led light fitting-input 100w with surge protection and cct - 3000k, having lamp housing or heat sink shall be made up of stainless steel or aluminimum or any other metal made from either extruded or pressure die casted or any manufacturing process to withstand lifetime performance and having high thermal conductivity material emitting luminous flux of 10000, input voltage220- 240v ac , 50 hz,, power factor greater than0.9 with wall/clamp based mounting arrangements, high bay module led light fitting-input 200w with surge protection and cct - 3000k, having lamp housing or heat sink shall be made up of stainless steel or aluminimum or any other metal made from either extruded or pressure die casted or any manufacturing process to withstand lifetime performance and having high thermal conductivity material emitting luminous flux of 20000, input voltage220- 240v ac , 50 hz,, power factor greater than0.9 with wall/clamp based mounting arrangements, light fitting bulk head light emitting diode type, the lamp housing or heat sink shall be made up of stainless steel or aluminimum or any other material made from either extruded or pressure die casted or any manufacturing process to withstand lifetime performance and having high thermal conductivity material emitting luminous flux of 900, input voltage220- 240v ac , 50 hz, input power of 10w, power factor greater than0.9 with wall/clamp based mounting arrangements or any matching / nearest & similar specifications as available other than basic parameters on gem portal as per approved demands, 10w bollard garden light sturdy ip66, ik08 luminaire light emitting diode type, the lamp housing or heat sink shall be made up of uv protected aluminimum pipe pressure die casted to withstand lifetime performance and having high thermal conductivity material emitting luminous flux of 5700k, input operating temperature -10 degree c to +45 degree c, operating voltage range 140 v - 270 v, average life l70 b50 50000 hours, 50 hz, thd less than 20 percentage , cri greater than80, 1050 lm power factor greater than0.95 with clamp based mounting arrangements, overall height 500 with ip67 connector. the top is like dome 92mm spitog dia with height 140mm, 15w bollard garden light sturdy ip65 luminaire light emitting diode type, 600mm height, the lamp housing or heat sink shall be made up of stainless steel or aluminimum or any other metal made from either extruded or pressure die casted or any manufacturing process to withstand lifetime performance and having high thermal conductivity material emitting luminous flux of 1350, input voltage220- 240v ac , 50 hz, power factor greater than0.9 with wall/clamp based mounting arrangements, 36w post top lantern landscape light sturdy ip65 luminaire light emitting diode type, the lamp housing or heat sink shall be made up of stainless steel or aluminimum or any other metal made from either extruded or pressure die casted or any manufacturing process to withstand lifetime performance and having high thermal conductivity material emitting luminous flux of 3240, input voltage220- 240v ac , 50 hz, power factor greater than0.9 with wall/clamp based mounting arrangements, water storage tank pvc 2000 ltrs 3-layer white colour virgin grade, 60w circular led post-top landscape light sturdy ip66, ik07 luminaire light emitting diode type, the lamp housing or heat sink shall be made up of pressure die cast aluminium body and opal pc cover and having high thermal conductivity material emitting luminous flux of 3000k cct, input voltage 240v ac, 0.26amp, 50 hz, thd less than 10 percentage , cri greater than77, 7450 lm power factor greater than0.95 with clamp based mounting arrangements suitable for pole dia dia 76 mm., powder coated decorative hot dipped galvanised mild steel step pole, 3.50m long suitable for led post top lanterns having plasma cut & duly chamfered opening window of 300x110 mm for terminal connections & mounting accessories mounting base mild steel base plate of dia 268 mm with 4 no. elliptical holes of 20x42 mm on 210mm pitch circle diameter suitable for m12 bolts, 60w pole top landscape light sturdy ip66, ik10 luminaire light emitting diode type, the lamp housing or heat sink shall be made up of aluminimum spigot pressure die casted to withstand lifetime performance and having high thermal conductivity material emitting luminous flux of 5700k, input voltage 240v ac, 0.26amp, 50 hz, thd less than 10 percentage , cri greater than77, 7450 lm power factor greater than0.95 with clamp based mounting arrangements. the top is like dome 80mm spitog dia with height 265mm, uv stabilized pure polyester coating led garden light pole base spun aluminium sheet along with the base plate is used having weight of 2.5kg having bottom section diameter of 140mm & 04 allien screws, 25w led spike light operated at 240v, 0.109 amps with greater than 0.95, 3000k(2160lm) , cri greater than 80, recess mounted round aluminium high efficiency light emitting diode swivel 38 degree spot light with power 3w rated at input voltage 230 v, power factor 0.90 frequency 50 hz operating temperature -10 degree c to 35 degree c, colour temperature 6500


Agency / Dept : indian army
Tender Value : 0
Due Date : Jun 13, 2026
T18 Ref No : 15412583
live Tender
Location : chatrapur , odisha
Source : GEM Tenders
live Tender

Tender Value : 414605
Due Date : Jun 08, 2026
T18 Ref No : 15289435
live Tender
Location : mumbai , maharashtra
Source : GEM Tenders
live Tender

tender for optional , making of ht cable transition joint pilc to xlpe optional , excavation of ht cable trench in soft soil or asphalt , ht cable trench excavation in concrete road optional , laying of ht xlpe cable 3cx240sqmm in excavated trench , laying of ht cable in rcc pipe or existing duct , supply of 200mm dia rcc pipe np2 class with collars , laying of rcc pipe and fixing of collars , supply of lt xlpe cable 3.5cx400sqmm to fp 6a , supply of lt xlpe cable 3.5cx400sqmm to fp 11 , supply of lt xlpe cable 3.5cx300sqmm to fp 1a , supply of lt xlpe cable 3.5cx300sqmm to fp 3 , supply of lt xlpe cable 3.5cx300sqmm to fp 4 , supply of lt xlpe cable 3.5cx300sqmm to fp 5 , supply of lt xlpe cable 3.5cx300sqmm to fp 6b , supply of lt xlpe cable 3.5cx300sqmm to fp 6c , lt cable trench excavation in asphalt paver area , laying of lt cable 3.5cx300 or 400sqmm in excavated trench , laying lt cable 3.5cx300 or 400sqmm in pipe or duct , supply of lt xlpe cable 3.5cx70sqmm to old cme building , excavation of lt cable trench for 70sqmm cable , laying of lt cable 3.5cx70sqmm in excavated trench , laying of lt cable 3.5cx70sqmm in rcc pipe or duct , cable termination material for 3.5cx70sqmm lt cable , cable termination installation for 3.5cx70sqmm lt cable , cable termination material for 3.5cx300sqmm lt cable , cable termination installation for 3.5cx300sqmm lt cable , cable termination material for 3.5cx400sqmm lt cable , cable termination installation for 3.5cx400sqmm lt cable , e-house foundation civil work , e-house shed supply and installation , rubble packing 250mm thick for cable trench reinstatement , stone metal 40-90mm layer for trench reinstatement , water bound macadam wbm layer for trench reinstatement , m10 grade rmc concrete levelling course , m40 grade rmc concrete road pavement , interlocking paver blocks 100mm thick , asphaltic macadam bitumen grade 60 70 regulating course , asphaltic concrete wearing course bitumen grade 60 70 , transporting surplus excavated material outside mbpa estate , dismantling of existing workshop substation, shifting of secondary substation at workshop to frere basin compound, supply of prefabricated containerized substation e-house having ip54 enclosure with 2 hr fire rated thermal insulation sandwich panel suitable for accommodating ht lt switchgear panel transformers battery bank battery charger and apfc panels as per technical specification, installation of the prefabricated containerized substation e-house at site including all necessary activities for proper placement and fixing as per oem drawings and instructions of engineer in charge, supply of 6.6kv eco-friendly indoor type green gis vcb switchgear panel with maximum system voltage 12kv 500mva rupturing capacity comprising 2 incomer 1 buscoupler 2 outgoing feeders 2 transformer feeders and 2 set bus pt as per technical specification, installation testing and commissioning of the 6.6kv ht gis vcb switchgear panel inside the e-house as per technical specification and in the presence of mbpa representative, supply of 24v dc smf-vrla battery bank of suitable load rating for ht and lt switchgear panels with minimum 1 hour backup including battery stand inter-battery wiring terminal connectors accessories and bhms as per technical specification, installation testing and commissioning of 24v dc smf-vrla battery bank inside the e-house as per technical specification and in the presence of mbpa representative, supply of float and float-cum boost charger suitable for battery bank including incoming and outgoing cables wires connection in ht switchgear and control panels with full wave rectification for 440v 3 phase 4 wire 50hz ac input supply as per technical specification, installation testing and commissioning of float and float cum boost charger inside the e-house as per technical specification and in the presence of mbpa representative, supply of iec 61439 compliant oem lt panel with tpn 2000a copper busbar 50ka 1 sec stc comprising 2 incomer acb 1 buscoupler acb 10 outgoing acb 5 mccb 400a 2 mccb 250a 2 mccb for apfc and 5 mcb outgoings as per technical specification, installation testing and commissioning of lt switchgear panel inside the e-house as per technical specification and in the presence of mbpa representative, supply of 1000 kva 6.6kv to 0.433kv dyn-11 copper wound an cooling cast resin dry type indoor transformer ip00 with off load tap links wti scanner class f insulation ht and lt cable boxes and standard accessories as per ecbc 2021 2 sets, installation testing and commissioning of 1000kva dry type transformer at site inside the e-house as per technical specification and in the presence of mbpa representative 2 numbers, supply of wall mounted smart local monitoring hmi box with windows 10 iot intel core i5 processor 8gb ram 64gb memory 15.6 inch touch screen iec 61850 client master application software for complete substation monitoring as per technical specification, installation testing and commissioning of smart local monitoring hmi system including integration with protection relays via iec 61850 ed 2 lan as per technical specification and in the presence of mbpa representative, supply of cubicle type free standing floor mounted apfc panels of 200 kvar capacity conforming to iec 61439 with mccb incomer capacitor banks detuned reactors apfc relay and all accessories as per technical specification 2 sets, installation testing and commissioning of apfc panels inside the e-house as per technical specification and in the presence of mbpa representative 2 numbers, supply of fire detection and alarm system comprising fire alarm control panel multi-area detection module multi sensor heat and smoke detectors break glass manual call points indoor and outdoor alarm hooters with ac shutdown interlock as per technical specification, installation testing and commissioning of fire detection and alarm system as per technical specification and in the presence of mbpa representative, supply of fire extinguishers as per is 3034-1993 of suitable capacity and type for the e-house substation application complete with all accessories and mountings, installation of fire extinguishers at designated locations inside the e-house as per directions of engineer in charge, supply of minimum 2 nos 2 ton copper coil inverter split air conditioners of heavy duty industrial type along with ac controller for e-house control room as per technical specification similar to o general hitachi samsung or equivalent, installation testing and commissioning of split air conditioners and ac controller inside the e-house as per technical specification and in the presence of mbpa representative, supply of suitable type touch proof termination kits as required for ht and lt power and control cables to and within the container equipment as per technical specification, installation testing and commissioning of ht and lt touch proof termination kits inside the e-house as per technical specification and in the presence of mbpa representative, supply of 600va ups system along with smf-vrla battery conforming to jisc-8702 pt 1 2 and 3 with single phase 230v ac 50hz output for e-house emergency illumination complete with all accessories, installation testing and commissioning of ups system with battery inside the e-house as per technical specification and in the presence of mbpa representative, supply and making of chemical earthing pit using chemical earth electrode with minimum 25 kg chemical powder cement concrete chamber 500x500x200mm ci rcc cover earthing rod 17.2mm dia 3 mtr long copper bonded 250 microns as per is 3043-2018 and iec 62561 16 numbers, supply and laying of galvanized ms earthing flat 50mm x 6mm for ht lt apfc battery charger and transformer body earthing of substation equipment as per technical specification, supply and laying of copper earthing flat 50mm x 6mm for transformer neutral earthing of the substation as per technical specification, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to tank bunder substation, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to pandv dock substation, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to central substation css, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to ro-ro pax terminal substation, tracing out existing buried 6.6kv ht cable laid feeder identification of existing feeder cable puncture and cutting in presence of mbpa representative contractor to arrange all necessary testing kits required for the same, supply of straight through joint for ht cable 3c x 240 sqmm xlpe insulated armoured aluminium conductor 11kv e 6.6kv ue grade using heat shrinkable raychem make jointing kit with ferrules tape etc complete in all respect, making of ht cable 6.6kv ue 11kv e grade straight through jointing work for cable 3c x 240 sqmm xlpe to xlpe in the presence of mbpa representative, carrying out necessary high potential test before and after making joints using calibrated testing equipment with complete test reports in the presence of mbpa representative, carrying out necessary phase sequence test using calibrated testing equipment with complete test reports and commissioning the cable in all respect in the presence of mbpa representative, supply of straight through transition joint for ht cable 3c x 240 sqmm xlpe insulated armoured aluminium conductor 11kv e grade using heat shrinkable raychem make jointing kit with ferrules tape etc complete in all respect optional, making of ht cable 6.6kv ue 11kv e grade straight through transition jointing work for cable 3c x 240 sqmm pilc to xlpe in the presence of mbpa representative optional, excavating suitable trench for ht cable in any type of soft soil or asphalt including cleaning cable trenches tentative size 1.0 mtr w x 1.2 mtr d x 300 mtr l, excavating suitable trench for ht cable in concrete or stone road including cleaning cable trenches tentative size 1.0 mtr w x 1.2 mtr d x 85 mtr l optional, laying of incoming and outgoing 3c x 240 sqmm xlpe aluminium armoured cable in excavated cable trench at depth 1200mm including cleaning dressing providing screened sand and rcc tiles engraved mbpa 6600 volts as per drawing, laying of ht cable in rcc pipe hdpe pipe existing duct or cc trench including all necessary activities as per specification, supply of rcc pipe 200mm dia np2 class of standard length with collars including cement concreting closing ends of pipes after passing cable across road culverts drains etc, laying of rcc pipe 200mm dia np2 class and fixing of collars at site including all necessary activities as per specification, supply and delivery of 3.5c x 400 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6a, supply and delivery of 3.5c x 400 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 11, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 1a, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 3, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 4, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 5, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6b, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6c, excavating suitable trench for lt cable in asphalt soil or paver block footpath with curb stone including cleaning cable trenches tentative size 0.8 mtr w x 0.9 mtr d x 700 mtr l, laying of incoming and outgoing 3.5c x 300 or 400 sqmm lt xlpe armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification, laying of incoming and outgoing 3.5c x 300 or 400 sqmm lt xlpe armoured cables in rcc pipe hdpe pipe existing duct cc trench or saddling on wall as per specification, supply and delivery of 3.5c x 70 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable for outgoing to old cme building sbi from fp no 4 nirman bhavan, excavating suitable trench for lt cable in asphalt soil or paver block footpath with cup stone including cleaning cable trenches tentative size 0.8 mtr w x 0.9 mtr d x 150 mtr l, laying of incoming and outgoing 3.5c x 70 sqmm lt xlpe armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification, laying of incoming and outgoing 3.5c x 70 sqmm lt xlpe armoured cables in rcc pipe hdpe pipe existing duct cc trench or saddling on wall as per specification, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 70 sqmm xlpe pvc cable 1100 volts grade 2 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 70 sqmm xlpe pvc cable 1100 volts grade 2 ends, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 300 sqmm xlpe pvc cable 1100 volts grade 6 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 300 sqmm xlpe pvc cable 1100 volts grade 6 ends, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 400 sqmm xlpe pvc cable 1100 volts grade 2 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 400 sqmm xlpe pvc cable 1100 volts grade 2 ends, suitable quantity dimensions and grade of concrete for e-house foundation columns including soil excavation as per oem design drawings and structural design approved by bmc registered structural engineer, supply and installation of e-house shed including foundation columns i-beams angles and covering sheets as per design drawings approved by bmc registered structural engineer, providing and laying approved quality rubble packing 250mm thick hand set including filling interstices with stone chips grit stone dust watering and consolidation as specified and as directed, providing and laying 40mm to 90mm size stone metal of approved quality to required thickness in layers not exceeding 120mm consolidated with roller including filling interstices with grit stone dust sand as directed, providing and laying water bound macadam wbm layer 100mm consolidated thickness with 40 to 63mm metal consolidated with roller including watering blending with sand stone dust grit brick powder as specified, providing and laying m10 grade ready mix cement concrete from approved rmc plant in levelling course of required thickness including transit mixer form work plate vibrator curing etc as specified, providing and laying m40 grade ready mix cement concrete from approved rmc plant in road pavement bays including form work power driven screed plate and needle vibrators brooming vatas bitumen curing as specified, providing and laying approved coloured cement concrete interlocking paver blocks 100mm thick with sand bedding minimum 50mm and filling joints with fine sand as directed, providing and laying hot pre-mixed asphaltic macadam bitumen grade 60 70 with anti-stripping agent 0.5 percent by weight in regulating course and rolling with 8 to 10 tonne road roller as specified payment by weight, providing and laying hot pre-mixed asphaltic concrete wearing course bitumen grade 60 70 with anti-stripping agent 0.50 percent by weight of required thickness and rolling with 8 to 10 tonne road roller as specified payment by weight, transporting surplus excavated material stones debris kutchra from mbpa estate including loading and taking away materials anywhere outside mbpa estate as directed, dismantling of existing ht lt panel transformers apfc panel battery charger and bank cables and cable terminations of existing workshop substation and shifting removed electrical equipment to mbpa store as per instructions of engineer


Agency / Dept : mumbai port trust MPT
Tender Value : 92399995
Due Date : Jun 08, 2026