Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Aluminum separator Tenders List

Latest Aluminum separator Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Aluminum separator tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Aluminum separator tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Aluminum separator Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Aluminum separator tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Aluminum separator Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Aluminum separator Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Aluminum separator Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Aluminum separator tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Aluminum separator Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Aluminum separator sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Aluminum separator tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Aluminum separator tenders.

Is EMD mandatory for all Aluminum separator tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Aluminum separator work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Aluminum separator tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Aluminum separator Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15206690
Location : dindigul , tamil nadu
Source : GEM Tenders

tender for operation and maintenance of electrical works in the gri campus 1 a copper bus bar size 1 x 1by8 with insulated by pvc color markings kindly refer the attach ment file , 2 aluminum bus bar size 1 x 1by8 with insulated by pvc color markings detailed specification please refer the data sheet in the attachment , 3.bus bar insulator - sm 35 include with bolt nut vassar and fixing charge detailed specification please refer the data sheet in the attachment , 4 l 250 x w 150 x thickness 2 point 5 mm hylam sheet fabric base mechanical grade detailed specification please refer the data sheet in the attachment , 5 the panel board overall made by 18 gauge metal sheets only detailed specification please refer the data sheet in the attachment , 6 trench excavation or digging and refilling charges only detailed specification please refer the data sheet in the attachment , 7 trench refilling charges only detailed specification please refer the data sheet in the attachment , 8 cable laying charges only size up to 35 sqmm refer description of work detailed specification please refer the data sheet in the attachment , 9 sand cushioning the cable protective covering with bricks and refilling the trench as required up to 35 sqmm refer the data sheet in the attachment , 10 cable laying charges only size from 35 sqmm to 95 sqmm refer description of work , 11sand cushioning the cable protective covering and refilling the trench from 35 to 95 sqmm please refer the data sheet in the attachment , 12 cable laying charges only size from 95 sq.mm to 185 sq.mm please refer the data sheet in the attachment , 13 sand cushioning the cable protective covering and refilling the trench from 95 sq.mm to 185 sq.mm please refer the data sheet in the attachment , 14 cable laying charges only from 185 sq.mm to 400 sq.mm detailed specification please refer the data sheet in the attachment , 15 sand cushioning the cable protective covering and refilling the trench.from 185 sq.mm to 400 sq.mm please refer the data sheet in the attachment , 16 ug cable laying work. up to 35 sq mm detailed specification please refer the data sheet in the attachment , 17 ug cable laying work 35 sqmm to 95 sqmm detailed specification please refer the data sheet in the attachment , 18 ug cable laying work 95 sqmm to 185 sqmm detailed specification please refer the data sheet in the attachment , 19 ug cable laying work 185 sqmm to 400 sqmm detailed specification please refer the data sheet in the attachment , 20 end termination charges 3and half x up to 16 sq. mm each or below detailed specification please refer the data sheet in the attachment , 21 end termination charges 3and half x 25 sq. mm 28mm detailed specification please refer the data sheet in the attachment , 22 end termination charges 3 and half x 35 sq mm 32mm detailed specification please refer the data sheet in the attachment , 23 end termination charges 3 and half x 50 sq mm 35 mm each detailed specification please refer the data sheet in the attachment , 24 end termination charges 3and half x 70 sqmm 38mm detailed specification please refer the data sheet in the attachment , 25 end termination charges 3 and half x 95 sqmm 45 mm each detailed specification please refer the data sheet in the attachment , 26 end termination charges 3 and half x 120 sqmm 45 mm each detailed specification please refer the data sheet in the attachment , 27 end termination charges 3and half x 150 sqmm 50 mm each detailed specification please refer the data sheet in the attachment , 28.end termination charges 3 and half x 185 sq. mm 57mm each detailed specification please refer the data sheet in the attachment , 29 end termination charges 3 and half x 225 sqmm 62mm detailed specification please refer the data sheet in the attachment , 30 end termination charges 3 and half x 240 sqmm 62mm each detailed specification please refer the data sheet in the attachment , 31 end termination charges 3and half x 300 sq. mm 70 mm detailed specification please refer the data sheet in the attachment , 32 end termination charges 3and half x 400 sqmm 82mm each detailed specification please refer the data sheet in the attachment , 33ug cable joining work labor charges only 3 and half x 25 sqmm each or below detailed specification please refer the data sheet in the attachment , 34 ug cable joining work labor charges only 3 and half x 35 sqmm each detailed specification please refer the data sheet in the attachment , 35 ug cable joining work labor charges only 3and half x 50 sqmm each detailed specification please refer the data sheet in the attachment , 36 ug cable joining work labor charges only 3 and half x 70 sqmm each detailed specification please refer the data sheet in the attachment , 37 ug cable joining work labor charges only 3and half x 95 sqmm each detailed specification please refer the data sheet in the attachment , 38 ug cable joining work labor charges only 3and half x 120 sqmm each detailed specification please refer the data sheet in the attachment , 39 ug cable joining work labor charges only 3and half x 150 sqmm each refer description of work , 40 ug cable joining work labor charges only 3 and half x 185 sqmm each detailed specification please refer the data sheet in the attachment , 41 ug cable joining work labor charges only 3 and half x 225 sqmm each detailed specification please refer the data sheet in the attachment , 42 ug cable joining work labor charges only 3 and half x 240 sqmm each detailed specification please refer the data sheet in the attachment , 43 ug cable joining work labor charges only 3 and half x 300 sqmm each detailed specification please refer the data sheet in the attachment , 44 ug cable joining work labor charges only 3and half x 400 sqmm each detailed specification please refer the data sheet in the attachment , 45 rcc cable root marker h 24 inchx w 8 inch x thickness 4 inch , 46 rcc pipes for road crossing 1feet dia x 6 inch length , 47 rcc pipes for road crossing half inch dia x 6 feet length , 48 rcc pipes for road crossing 9 inch dia x 6 feet length , 49 ug cable eb service related work up to 16 sqmm detailed specification please refer the data sheet in the attachment , 50 ug cable eb service related work above 16 to up to 35 sqmm detailed specification please refer the data sheet in the attachment , 51 ug cable eb service related work above 35 sqmm up to 95 sqmm detailed specification please refer the data sheet in the attachment , 52 ug cable eb service related work above 95 sqmm up to 185 sqmm detailed specification please refer the data sheet in the attachment , 53 himast 12 mtr light pole detailed specification please refer the data sheet in the attachment , 54 openwiring for light point fan point exhaust fan point call bell point detailed specification please refer the data sheet in the attachment , 55.concealed wiring for light point fan point exhaust fan point call bell point detailed specification please refer the data sheet in the attachment , 56.wiring for twin control light point with open wiring detailed specification please refer the data sheet in the attachment , 57 wiring for twin control light point concealed wiring detailed specification please refer the data sheet in the attachment , 58 wiring for light or power plug open wiring with 2 x 4or 6or 10 sq. mm detailed specification please refer the data sheet in the attachment , 59 wiring for light or power plug concealed wiring with 2 x 4 or 6 or 10 sq. mm detailed specification please refer the data sheet in the attachment , 60 wiring for light or power plug with 4 x 4 or 6 or 10 sq. mm open wiring detailed specification please refer the data sheet in the attachment , 61 wiring for light or power plug with 4 x 4 or 6 or 10 sqmm copper conductor concealed wiring please refer the data sheet in the attachment , 62 wiring for separate circuit for air condition point open wiring detailed specification please refer the data sheet in the attachment , 63 wiring for separate circuit for air condition point wiring concealed wiring detailed specification please refer the data sheet in the attachment , 64 wiring for circuit or sub main wiring 2x1dot5 sqmm plus 1x1dot5 sqmm earth wire detailed specification please refer the data sheet in the attachment , 65 wiring for circuit or sub main wiring 4x1 dot 5sqmm plus x1dot5 sqmm detailed specification please refer the data sheet in the attachment , 66 wiring for circuit or sub main wiring2 x 2dot5 sqmm plus 1x1dot5 sqmm earth wire detailed specification please refer the data sheet in the attachment , 67 wiring for circuit or sub main wiring 4 x 2dot5sqmm plus 1x1dot5 sqmm earth wire detailed specification please refer the data sheet in the attachment , 68 wiring for circuit or submain wiring 2 x 4 sqmm plus 1 x 1dot5 sqmm earth wire detailed specification please refer the data sheet in the attachment , 69 wiring for circuit or sub main wiring 4 x 4 sqmm plus 1 x 1dot5 sqmm earth wire detailed specification please refer the data sheet in the attachment , 70 wiring for circuit or sub main wiring 4 x 6 sqmm plus 2 x 6 sqmm. earth wire detailed specification please refer the data sheet in the attachment , 71 wiring for circuit or sub main wiring 4 x 10 sqmm plus 2 x 6 sqmm earth wire detailed specification please refer the data sheet in the attachment , 72 wiring for circuit or sub main wiring 4 x 16 sqmm plus 2 x 6 sqmm earth wire detailed specification please refer the data sheet in the attachment , 73 installation led fitting of all types complete with all accessories detailed specification please refer the data sheet in the attachment , 74 installation street light led fitting of all types, complete with all accessories detailed specification please refer the data sheet in the attachment , 75 installation of ceiling fan detailed specification please refer the data sheet in the attachment , 76 installation of wall mount fan detailed specification please refer the data sheet in the attachment , 77 service board and main board wiring 1 phase , 78 service board and main board wiring 3 phase , 79 wire running charges for above 5 meters 2 x 1dot5 sqmm plus 1 x 1dot5 sqmm detailed specification please refer the data sheet in the attachment , 80 wire running charges for above 5 meters 4 x 1dot 5 sqmm plus 1 x 1dot5 sqmm detailed specification please refer the data sheet in the attachment , 81 wire running charges for above 5 meters 2 x 2dot5 sqmm plus 1 x 1dot 5 sqmm detailed specification please refer the data sheet in the attachment , 82 wire running charges for above 5 meters 4 x 2dot5 sqmm plus 1 x 1dot5 sq.mm detailed specification please refer the data sheet in the attachment , 83 wire running charges for above 5 meters 2 x 4 sqmm plus 1 x 1dot5 sqmm detailed specification please refer the data sheet in the attachment , 84 wire running charges for above 5 meters 4 x 4 sqmm plus 1 x 1dot5 sqmm detailed specification please refer the data sheet in the attachment , 85 wire running charges for above 5 meters 4 x 6 sqmm plus 1 x 1 dot 5 sqmm detailed specification please refer the data sheet in the attachment , 86 wire running charges for above 5 meters 4 x 10 sqmm plus 1 x 1dot 5 sqmm detailed specification please refer the data sheet in the attachment , 87 wire running charges for above 5 meters 4 x 16 sqmm plus 1 x 1dot5 sq.mm detailed specification please refer the data sheet in the attachment , 88 replacing charge of following 2way or 4ways surface or recess mounting vertical type tpn mcb db please refer the data sheet in the attachment , 89 fixing charge of following 2way or 4ways surface or recess mounting vertical type tpn mcb db please refer the data sheet in the attachment , 90 replacing charge of vertical type tpn mcb db 8 way please refer the data sheet in the attachment , 91 fixing charge of vertical type tpn mcb db 8 way please refer the data sheet in the attachment , 92 replacing charge of vertical type tpn mcb db 12 way please refer the data sheet in the attachment , 93 fixing charge of vertical type tpn mcb db 12 way please refer the data sheet in the attachment , 94 replacing charge of vertical type tpn mcb db 16 way please refer the data sheet in the attachment , 95 fixing charge of vertical type tpn mcb db 16 way please refer the data sheet in the attachment , 96 replacing charge of vertical type tpn mcb db 24 way please refer the data sheet in the attachment , 97 fixing charge of vertical type tpn mcb db 24 way please refer the data sheet in the attachment , 98 replacing of exfan on the surface connection testing commissioning etc as required please refer the data sheet in the attachment , 99 fixing of exfan on the surface connection testing commissioning etc as required please refer the data sheet in the attachment , 100 replacing 1way or 2 way 6a piano type switch or socket on the existing switch box or cover please refer the data sheet in the attachment , 101 fixing 1way or 2 way 6a piano type switch or socket on the existing switch box or cover please refer the data sheet in the attachment , 102 replacing piano type switch or socket on the existing switch box or cover 20 amps switch socket please refer the data sheet in the attachment , 103 fixing piano type switch or socket on the existing switch box or cover 20 amps switch socket please refer the data sheet in the attachment , 104 replacing electronic type regulator on the existing switch box or cover please refer the data sheet in the attachment , 105 fixing electronic type regulator on the existing switch box or cover please refer the data sheet in the attachment , 106 replacing charge 5a ceiling rose on the existing junction box or wooden block detailed specification please refer the data sheet in the attachment , 107 fixing charge 5a ceiling rose on the existing junction box or wooden block detailed specification please refer the data sheet in the attachment , 108 replacing 5a brass batten or angle holder including connection detailed specification please refer the data sheet in the attachment , 109 fixing 5a brass batten or angle holder including connection detailed specification please refer the data sheet in the attachment , 110 replacing tpn disconnector fuse switch unit inside the existing panel board 63a please refer the data sheet in the attachment , 111 fixing tpn disconnector fuse switch unit inside the existing panel board 63a please refer the data sheet in the attachment , 112 replacing tpn disconnector fuse switch unit inside the existing panel board 125 or 100a please refer the data sheet in the attachment , 113 fixing tpn disconnector fuse switch unit inside the existing panel board 125 or 100a please refer the data sheet in the attachment , 114 replacing tpn disconnector fuse switch unit inside the existing panel board 160a please refer the data sheet in the attachment , 115 fixing tpn disconnector fuse switch unit inside the existing panel board 160a please refer the data sheet in the attachment , 116 replacing tpn disconnector fuse switch unit inside the existing panel board 200a please refer the data sheet in the attachment , 117 fixing tpn disconnector fuse switch unit inside the existing panel board 200a please refer the data sheet in the attachment , 118 replacing tpn disconnector fuse switch unit inside the existing panel board 400a please refer the data sheet in the attachment , 119 fixing tpn disconnector fuse switch unit inside the existing panel board 400a please refer the data sheet in the attachment , 120 replacing 4p change over switch unit inside the existing panel board 63a detailed specification please refer the data sheet in the attachment , 121 fixing 4p change over switch unit inside the existing panel board 63a detailed specification please refer the data sheet in the attachment , 122 replacing 4p change over switch unit inside the existing panel board detailed specification please refer the data sheet in the attachment , 123 fixing 4p change over switch unit inside the existing panel board 100 or 125 or 160a detailed specification please refer the data sheet in the attachment , 124 replacing 4p change over switch unit inside the existing panel board 200a detailed specification please refer the data sheet in the attachment , 125 fixing 4p change over switch unit inside the existing panel board 200a detailed specification please refer the data sheet in the attachment , 126 replacing 4p change over switch unit inside the existing panel board 400a detailed specification please refer the data sheet in the attachment , 127 fixing 4p change over switch unit inside the existing panel board 400a detailed specification please refer the data sheet in the attachment , 128 replacing 4p change over switch with enclosure 63 or 100 or 160 a detailed specification please refer the data sheet in the attachment , 129 fixing 4p change over switch with enclosure 63 or 100 or 160 a detailed specification please refer the data sheet in the attachment , 130 replacing 4p change over switch with enclosure 200a detailed specification please refer the data sheet in the attachment , 131 fixing 4p change over switch with enclosure 200a detailed specification please refer the data sheet in the attachment , 132fixing single pole 5 amps to 32 amps rating detailed specification please refer the data sheet in the attachment , 133 replacing single pole 5 amps to 32 amps rating detailed specification please refer the data sheet in the attachment , 134 replacing double pole 5 amps to 32 amps rating detailed specification please refer the data sheet in the attachment , 135 fixing double pole 5 amps to 32 amps rating detailed specification please refer the data sheet in the attachment , 136 replacing triple pole 4 pole replacing charge 5 amps to 63 or 100a rating detailed specification please refer the data sheet in the attachment , 137 fixing triple pole 4 pole replacing charge 5 amps to 63 or 100a rating detailed specification please refer the data sheet in the attachment , 138 replacing double pole isolater 40 amps detailed specification please refer the data sheet in the attachment , 139 fixing double pole isolater 40 amps detailed specification please refer the data sheet in the attachment , 140 replacing double pole isolater 63 amps detailed specification please refer the data sheet in the attachment , 141 fixing double pole isolater 63 amps detailed specification please refer the data sheet in the attachment , 142 replacing four pole isolater 40 amps detailed specification please refer the data sheet in the attachment , 143 fixing four pole isolater 40 amps detailed specification please refer the data sheet in the attachment , 144 replacing four pole isolater 63 amps detailed specification please refer the data sheet in the attachment , 145 fixing four pole isolater 63 amps detailed specification please refer the data sheet in the attachment , 146 replacing 16or25or32amps tp mcb detailed specification please refer the data sheet in the attachment , 147 fixing 16 or 25 or 32a tp mcb detailed specification please refer the data sheet in the attachment , 148 replacing 20a 240 volts, spn industrial type detailed specification please refer the data sheet in the attachment , 149 fixing 20a 240 volts, spn industrial type detailed specification please refer the data sheet in the attachment , 150.replacing capacity rising mains 200 amps detailed specification please refer the data sheet in the attachment , 151.fixing capacity rising mains 200 amps detailed specification please refer the data sheet in the attachment , 152.replacing tpn tap off box 16 or 32 or 63 or 100 amps tpn detailed specification please refer the data sheet in the attachment , 152 fixing tpn tap off box 16 or 32 or 63 or 100 amps tpn detailed specification please refer the data sheet in the attachment , 154 earthing with g.i. earth plate 600 mmx600mmx6 mm thick including accessories detailed specification please refer the data sheet in the attachment , 155 earthing with copper earth plate 600mmx600mmx6mm thick including accessories detailed specification please refer the data sheet in the attachment , 156 earthing with gi earth pipe 1 meter long, 40mm dia including accessories detailed specification please refer the data sheet in the attachment , 157 earthing with gi earth pipe 2 meters long , 40mm dia including accessories detailed specification please refer the data sheet in the attachment , 158 earthing with gi earth pipe 3 meter long 40mm dia including accessories detailed specification please refer the data sheet in the attachment , 159 laying earth connection from earth electrode with 4mm dia copper wire in 15 mm dia gi pipe please refer the data sheet in the attachment , 160 laying earth connection from earth electrode with 25mmx5mm copper or gi flat strip gi pipe please refer the data sheet in the attachment , 161 fixing 4mm dia copper wire on surface or in recess for loop earthing along conduit or sub main or cable as required , 162 laying zero point 5 mm telephone line wiring in surface or recessed pvc conduit, , 163 drawing lan cable or coaxial tv cable rg6 grade 0.7mm solid copper conductor in the existing surface or recessed steel or pvc conduit , 164 labour rate for electrical helper , 165 labour rate for excavator , 166 ups and battery dismantling charges including battery to ups and ups to feeding terminal point terminating wires switches sockets etc up to 3 kva , 167 ups and battery installation charges including battery to ups and ups to feeding terminal point terminating wires switches sockets etc up to 3kva , 168 ups and battery installing charges including battery to ups above 3kva to 5kva please refer the data sheet in the attachment , 169 ups and battery dismantling charges including battery to ups above 3kva to 5kva please refer the data sheet in the attachment , 170 ups and battery installing charges including battery to ups above 5kva to 10kva please refer the data sheet in the attachment , 171 ups and battery dismantling charges including battery to ups above 5kva to 10kva please refer the data sheet in the attachment , 172 ups and battery installing charges including battery to ups above 10kva please refer the data sheet in the attachment , 173 ups and battery dismantling charges


Tender Value : 300000
Due Date : May 21, 2026
T18 Ref No : 15143091
Source : GEM Tenders

tender for providing and supplying rollar blinds ami make or approved make and shade of 38mm round aluminium channel with blackout fabric and telting with chain (ball) system with all necessary fixtures and fitting etc. complete. (sample to be final by engineer incharge prior execution of work), providing and supplying vertical blinds of approved make and shade of 100mm regular fabric with powder coated aluminium channel with telting pvc chain and bottom weight plate with all necessary fixtures and fitting etc. complete. (sample to be final by engineer incharge prior execution of work), providing and supplying cube main table assy 50mm thk mdf veneer with bbf pedestal one side lhs 2400wx1200dx750h with return storage with wooden drawer assly. lh at 1800 x 600 x 625 ht. and cube back storage with 3 door assly. at 1650 x 600 x 625 ht. 3nos. back unit cube back upper storage assly. open shelf with glass door.at 1650 x 450 x 1475 ht. 2 nos. for ms cabin, providing and supplying table of size1500lx750dx750ht top made from 25 mm prelaminated particle board all edage are covered by 2 mm thk pvc edge bands glued by hot melt glue gable ends made from 25 mm prelaminated particle board all edage are covered by 0.8mm pvc edge bands glued by hot melt glue applied by auto edge banding machine. modesty panel made from 18mm bolt side prelaminated particle board. all edage are covered by 0.8mm pvc edge bands glued by hot melt gule applied by auto edge banding machine. keyboard tray ( without mouse tray) metal powder coated black colour cpu trolley metal powder coated black colour 3 drawers pedestal unit having overall size 405mmx 460mmx 685mm with central lock and key drawers are complete metal powder coated with ball bearing slide for 2 book drawers and telescopic slide for filling drawer,body and facia in 18 mm pre laminated particle board as per design and drawing and instructions of engineer in charge, providing and supplying of main table at 3600lx1400dx750ht made up of 1818mm thick mdf top with pvc membrane finish and waterfall edge profile. aluminium anodizied finish beeding of 4mm thich is running all over the table top edge. gable ends is aerofoiled shape with front edges in pvc membrane finish and rest in prelaminated mdf with batton structure. gable ends should be hollow from inside for the provision of passing electrical and data wiring. , modesty panel to be made of 18 mm thick prelaminated particle board with pvc edge band\naccess flap for wire manager 2 nos., supply, fitting and fixing of prelam table at 1500lx600dx750ht. with 2b1f pedestal at 400lx450dx670ht.\nwork top shall be made up of work top shall be made 25mm thick prelam (osl) particle board confirming to is 12823 1990 with 2mm thick pvc lipping glued with kliberit779.6 glue. work top is under goes from distributed load test for deflection by applying 0.027kg mm load on top and concentric load test by applying 90kg load on weaker section\nunderstructure modesty panel shall be made of 18mm thick prelam bsl particle board confirming to is 12823 1990 with 2mm thick pvc lipping glued with kliberit779.6 glue. gable ends shall be made of 25mm thick prelam bsl particle board confirming to is12823 1990. the construction shall be aesthetically appealing completely knock down construction fitting is done by using the minifix and dowels. gable end height will be 725mm and its depth varies as per the depth of work top. standard depth of work top will be 600mm and 750mm.\nwire management wire manager cap on the table top shall be made of abs material having diameter 63.5mm standard.the product must be from a manufacturer having iso 9001,iso 14001,latest bifma 5.1 certificates for few of its products., supply, fitting and fixing of prelam cabin at 1350lx600dx750ht. with 2b1f pedestal at 400lx450dx670ht.\nwork top shall be made up of work top shall be made 25mm thick prelam (osl) particle board confirming to is 12823 1990 with 2mm thick pvc lipping glued with kliberit779.6 glue. work top is under goes from distributed load test for deflection by applying 0.027kg mm load on top and concentric load test by applying 90kg load on weaker section\nunderstructure modesty panel shall be made of 18mm thick prelam bsl particle board confirming to is 12823 1990 with 2mm thick pvc lipping glued with kliberit779.6 glue. gable ends shall be made of 25mm thick prelam bsl particle board confirming to is12823 1990. the construction shall be aesthetically appealing completely knock down construction fitting is done by using the minifix and dowels. gable end height will be 725mm and its depth varies as per the depth of work top. standard depth of work top will be 600mm and 750mm.\nwire management wire manager cap on the table top shall be made of abs material having diameter 63.5mm standard.the product must be from a manufacturer having iso 9001,iso 14001,latest bifma 5.1 certificates for few of its products.\n2b1f pedestal at 400lx450dx670ht. specifications \npedestal top shall be made 18mm thick prelam (osl) particle board confirming to is 12823 1990 with 2mm thick pvc lipping glued with kliberit779.6 glue. table top is under goes from distributed load test for deflection by applying 0.027kg mm load on top and concentric load test by applying 90kg load on weaker section, providing and supplying openable steel storage of 750 x 450 x 1200ht, with 2 adjustable shelves, complete body and shutter made in 0.8 mm thick and top in 2 mm thick crca, 2 shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk. as per drawing., supply, fitting and fixing of prelam cabin. at 1500lx600dx750ht.\nwork top shall be made up of work top shall be made 25mm thick prelam (osl) particle board confirming to is 12823 1990 with 2mm thick pvc lipping glued with kliberit779.6 glue. work top is under goes from distributed load test for deflection by applying 0.027kg mm load on top and concentric load test by applying 90kg load on weaker section\nunderstructure modesty panel shall be made of 18mm thick prelam bsl particle board confirming to is 12823 1990 with 2mm thick pvc lipping glued with kliberit779.6 glue. gable ends shall be made of 25mm thick prelam bsl particle board confirming to is12823 1990. the construction shall be aesthetically appealing completely knock down construction fitting is done by using the minifix and dowels. gable end height will be 725mm and its depth varies as per the depth of work top. standard depth of work top will be 600mm and 750mm., supply, fitting and fixing of sos make metal storage\nstorage body the construction and material of storage body shall be of 0.8mm thick crca and skirting shall be of 1.2mm thick crca sheet confirming to is 513 2008 with powder coated finish up to 50 to 60 micron. the storage top shall be made up of 2mm thick crca sheet with 0.7 mm thick crca sheet that for extra support. shelf shall be made up of 0.8mm crca sheet confirming to is 513 2008 with 0.8mm thick crca sheet that is given for extra support. shelf shall be mounted with the metal shelf support pin made of 2mm thick crca sheet with nickel or chrome plating. load bearing capacity of the shelf shall be 30kgs udl. the construction shall be aesthetically appealing completely welded. m10 screw leveler is given with height adjustment up to 12mm to 15mm\n\nmetal shutter shall be made up of 0.8mm crca sheet confirming to is 513 2008 with powder coated finish up to 50 to 60 micron and 0.8 mm crca sheet t hat is given for extra support and to screw hinges on shutter. shutter is hinged shutter with equal width hung with 0 crank on side panel. multipurpose square lock is used to lock the shutter. pvc flush handles are used in metal shutter., providing and supplying of book case with glass shutter at 825lx300dx1650ht to be made out of complete body and in 0.7mm thick crca and shutter in 1.2mm thick crca with glass pannel in powder coating finish as per drawing., providing and supplying multiple compartment lockers at 1140lx 457d x 1830 mm. ht. with 12 compartments , complete body and shutter made of crca sheet with powder coated finish as per approved color., providing and arrangemnt of high back, synchronized mechanism with multiple locking, adjustable armrest, gaslift for seat height adjustment, standard 5prong p nylon base with leatherite upholstery, providing and arrangemnt of high back chair tilt mechanism with multilocking, high density cushion on seat composite leather with metallic silver finish base and arms with p.u.castors gaslift for height adjustment., providing and supplying adjustable seat height, armrest, locking mechanism, seat lock, swivel, wheels, head support w x h 63 cm x 114 cm frame material sold wood upholstery type cushion diy basic assembly to be done with simple tools by the customer, comes with instructions., providing and supplying make wipro company. the seat and back shall be made up of wood veneer with foam back. the chair can also be provided with fixed wooden armrests .the dimensions of back shall be 49 cm (w) x 37 cm (h) and of seat shall be 51 cm (w) x 50.0cm (d). the seat and back inner shall be upholstered with pu foam and fabric and shall be assembled over the seat and back. the chair is made of rubber wood veneer with thickness of the leg 25 mm and width of the leg at 28mm. seat height 46 cm, height83.0cm, width and depth of chair as measured from base width60.0cm and depth56.0 cm.dimensions tolerance variations shall be within 1 cm., providing and arrangemnt of mid back, normal syncro mechanism , fixed armrest , gaslift for seat height adjustment, standard 5prong nylon base with leather upholstery, providing and supplying 4 legged lab stool, legs made of 16 guage 45 mm outer dimension ms pipe, duly painted, with a 304 grade stainless steel 12 inch wide seat with a 1 inch collar, height adjustment via a screw. as per design and drawing and instructions of engineer in charge., providing and supplying foldable alluminum ladder 1500 mm. ht., providing and supplying of tea table 900mm x 750mm x 450mm with 12mm thick colour eitched tempered glass with bevelled drawing made out of 18mm thick waterproofing ply. the outer laces to be finished with high quality 4 mm thik veneer or 1 mm thik mica etc., providing and supplying 3 seater public seating chair made of complete metal with legs in crome finish and seates in silver powder coating finish., providing and supplying two seater tandem chair with metal seat and back, main frames to be made out of dia 50 x 1.6 mm wall thickness and arms are made out of erw oval tubes of size 48 x 22 and 1.6 mm wall thickness. seat and back frames to be made out of erw tube dia 16 x 1.2 mm wall thickness, seat and back are made out of crca 1.6 mm thickness duly perforated, with nickel chromium plated decorative knobs. all metal should be powder coated .three seater (tandem) chair will be sent in knock down condition and be assembled at site, as per design and drawing and instructions of engineer in charge., providing and supplying single bed of size 2025lx1000dx650h with matress and pillow. understructure the legs are made of square tube of size 25 x 25mm made out of ms with a thickness of 1.2 mm. the legs should have corner brackets welded to it at two levels. the corner brackets are made of 2mm thick crca having a l shaped structure to join the side panels and headboard to the leg. three nos. of horizontal stiffeners are provided at equal intervals. the stiffeners are made of square tube of size 25 x 25mm made out of ms with a thickness of 1.2mm. the middle horizontal stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. this leg is also made of square tube of size 25 x 25mm made out of ms with a thickness of 1.2mm. all metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 microns dft.side panel the side panels are made up of 18mm thick prelam particle board with both side decorative laminate. all exposed edges are sealed with 2mm thick pvc edge banding. the overall width of the side panel is 150mm. the side panels have 18mm thick prelam particle board baton running for required length to add rigidity to the structure.\nhead board the head board is made up of 18mm thick prelam particle board with both side decorative laminate. all exposed edges are sealed with 2mm thick pvc edge banding. the head board size to be considered as 1000 x 650mm.\nfoot board the foot board is made up of 18mm thick prelam particle board with both side decorative laminate. all exposed edges are sealed with 2mm thick pvc edge banding. the head board size to be considered as 1000 x 450mm.\nbed base the bed base is made up of 12mm thick prelam particle board with both side white laminate., providing and supplying dressing table of size 400lx 400dx 1800h.the dressing table unit is made up of 18mm thick prelam particle board with both side decorative laminate. all exposed edges are sealed with 2mm thick pvc edge banding. the unit has one drawer and one shelf. the dressing table has a mirror of 4mm thick pasted on 18mm thick prelm particle board attached to the base unit. the mirror size considered is 1155 x 360 x 4(t). the mirror has been pasted using high quality 3m sticker., providing and supplying bed side table of size 400lx 400dx 415h the bed side unit is made up of 18mm thick prelam particle board with both side decorative laminate. all exposed edges are sealed with 2mm thick pvc edge banding. the bed side table has one drawer and one shelf. the shelf is made of 18mm thick prelam particle board with both side decorative laminate. all exposed edges are sealed with 2mm thick pvc edge banding, providng and fixing factory finish 3 seater sofa made of imported red miraty ood with foam in 40 density for seat and for back in 28 density.premium quality cenflax p.u. foam ith letherite upholstry as per design and drawing and as directed by engineerincharge, providing and supplying factory finish 1 seater sofa made of imported red miraty wood with foam in 40 psi density for seat and back in 28 psi dnsity premium quality sunflex pu foam with leather upholstry as per design and dwg and instructions of engineerincharge, providing and fixing slotted angle storage rack at 905l x 605 x 2400 ht shlf to be made of 1 mm crca powder coated vertical members made of 35x35x1.5 crca,base plate at bottom which can be usd for grouting of the shelf including asembly hardware as per design and drawing and instructions of engineerincharge, supply, fitting and fixing of prelam storage.\nstorage top shall be made of 25mm thick prelam (osl) particle board for low height prelam storage up to 750 height and above 750 mm height 18mm thick prelam (osl) particle board is used. both the 25mm and 18mm thick prelam (osl) particle board confirming to is 12823 1990 with 2mm thick pvc lipping glued with kliberit779.6 glue. storage top is under goes from distributed load test for deflection by applying 0.027kg mm load on top and concentric load test by applying 90kg load on weaker section. load carrying capacity of 18mm thick shelf shall be 25kgs udl., providing and supplying full height partitions in solid finish providing and supplying 80mm to 85mm thick full height double skin partition up to 3 mtr height with all visible sections in anodized powder coated finish. made up of frames and tiles. frame construction in combinaton of aluminium rails and bottom ,center and top members, connected with 2 way round shape post , 3way post , 4 way post made up of aluminium extruded and tiles in 9mm thk. prelaminated partical board of on both side. with all the joints in the partitions covered with pvc extrusions to provide better sound proofing. tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing., providing and supplying 80mm to 85mm thick full height double skin partition up to 3 mtr height with all visible sections in anodized powdercoated finish. made up of frames and tiles. frame construction in combinaton of aluminium rails and bottom ,center and top members, connected with 2 way round shape post , 3way post , 4 way post made up of aluminium extruded and tiles in 5mm thk. non toughened glass on both side. with all the joints in the partitions covered with pvc extrusions to provide better sound proofing. tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing., providing and supplying of glass door and frame at 900mm x 2100mm 12mm thk toughened glass door with frame in anodized aluminium with rubber gasket on both verticals for better sound proofing and provision for one side opening along hardware consisting of floor spring dorma equivalent, patch fitting , lock, door stopper and handle, as per design and drawing and instructions of engineer in charge., providing and supplying medium height partition at 1800 1200ht tile based partition system tile based aluminum partition system of 1800 1200mm ht. made of 60mm thick aluminum frames having two separate race ways for laying electrical and computer wiring. the wire management shall be through to the race way to be fitted at bottom of partition other immediately below of work top with hook on type raceway cover for easy access of wires. frames to be joined by aluminum connectors with m6 x 16 panhead machine screw and washer with aluminum post cover. post cover snap on fashion to be connected on aluminum connector visible aluminium to be in anodized powdercoated finish. the top exposed sides of the frame and posts should be covered with horizontal vertical trim and caps made of aluminum in anodized powdercoated finish in order to enhance its look.upper tiles on the partition to be in soft board or marker or prelaminated partical board tile of 9mm. thk., prelaminated partical board lower tiles in laminate finish 9mm. thk. on both the sides .size 1200 1800mm (h), providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 mm x 60 mm with 12 mm thick three layered flat pressed teak wood particle board bonded with bwp type exterior grade phenol formaldehyde synthetic resin conforming to is 128231990, laminated on both sides,novateakor equivalent and 5 mm thick selected quality plain float glass panels fixed with aluminum glass clips 12 mm x 12 mm and rubber cushioning beading to glass partitions as per approved drawing etc. compete.colour anodized, providing and fixing in position, double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00, supplying single piece plastic moulded chair of size 510 mm x410mm x790 mm with arm rest of approved colour with 1 year waranttee as directed by engineer in charge, providing and supplying storage of size 1600wx450dx650h in combination of three drawers unit with soft closing slides and openable shutter unit with shutters made of mdf with membrane finish and body is made of 0.8 mm thickness crca sheet with radius of 50 mm on all four minor lengths to avoid sharp edges with powder coat finish.storage supported with legs made of alumnium t section for main support along with front portion covered with natural maple wood in melemaine finish toi enhance the asthetics as per design and drawing and as directed by engineer in charge, providing and supplying fire exit and floor identification signage as per manufacturers specifications, ada compliant and modular system, providing and supplying ss braille buttons directional signage in the elevator of the approved brand and make to be installed using the specified adhesive and as per the instructions given by the manufacturer, providing and supplying of high intensity reflective conspicuity tape 25 to 50mm width, on edges of treads in staircase including, cutting, pasting etc. of make 3m or equivalent brand as per the direction of engineer in charge, providing a folding wheelchair of pioneer surgicals brand, model number ps 809 equivalent make as per the directions of the engineer in charge., providing and supplying free standing finish type natural burnt suitable for general utility furniture, bedroom upholstery included number of panels 3 foldable screen type decorative screen model series name handcrafted 3 panel wooden mdf room divider screen with stand included primary material wood primary material subtype wood secondary material wood secondary material subtype mdf primary color brown finish color brown dimensions width 152.4 cm height 182.88 cm depth 1.828 cm other dimensions each panel length 20 inch, height 72 inch, provinding and fixing signages of various size as per design of whit 6 mm imported acrylic sheet with laser cut vinyl ltters over acrylic sheet including all lead,lift and necessary fixtures required etc complete., provinding and fixing maharashtra government department logo using wood platic composite or equivalent with exteriror colur and polish in size 6 feet x 2 feet, dust bin supplying dust bin of polypropelene material 10 lit, door mat supplying door mat of size 3 feeet x 2 feet, providing and supplying 25 mm thick bed side platform at 2200lx450d. for room top 25 mm thick prelaminated board, with wall mounting brackets, providing and supplying ss dining table with folding chair for dining top top is made up of stainless steel having a length of 1800(l) x 760(d) x 750(h) confirming the grade 304 understructure \nunderstructure legs vertical member are made up of 40 x 40 x 1.2 mm thick ms pipe confirming the is 4932 with powder coated finish up to 50 to 60 micron. horizontal member is made up of 25 x 25 x 1.2 mm thick confirming the is 4923with powder coated finish up to 50 to 60 micron. both the horizontal and vertical pipes are welded together by mig welding confirming to is standard is 8161969 and it is welding also tested by confirming to is 8221970. understructure height will be 725mm from the ground, and the bench height will be 500mm from the ground., providing and supplying pre laminated particle board shoe rack, grooves and joints has made a reputed name for itself in the market with highquality modular wardrobe, pre laminated particle board shoe rack


Tender Value : 0
Due Date : May 08, 2026
T18 Ref No : 14919781
Location : senapati , manipur
Source : GEM Tenders

corrigendum tender for proc of prc items for qe mar 2026 of ge 869 ews ii xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , pvc insulated copper cable single core and multi core circular sheathed with flexible conductor (v2) isi marked to is 694 (q2) , electrical plugs (v2) isi marked to is 1293 (q2) , elecric bells and accessories as per is 2268 (q3) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , 09 or 10 watt led bulb white , flexible wire copper twin core sheathed 40 0.076 , pvc copper cable single core 2.5 sqmm , led focus light 15 watt , prospot cob swival led light 15 watt , ht cable end joint kit 95 sqmm , 05 watt led b22 bulb white , pvc copper 1.5 sqmm single core , heating element 2000 watt , pvc copper cable single core 4 sqmm , pvc cashing caping 25mm , pvc cashing caping 20mm , flexible wire copper twin core sheathed 23 0.076 , moudlar plate 12m , modular box 12m , pvc copper cable single core 6 sqmm , db 8 way double door , decorative tipe led spot light 5w focus light 230v 50hz , led batten fitting 2 feet long , thermostat for geyser , pvc switch board rectangle 8 inch x12 inch , moudlar plate 8m , modular box 8m , fan regulator modular , pvc copper cable twin core 1.5 sqmm , ht fuse element 11000 volts 5 amps , ht fuse element 11000 volts 20 amps , ht fuse element 11000 volts 10 amps , ht cable jointing kit 3.5 corex95sqmm outdoor , switch socket combination 616 amp multi , switch socket combination 3 pin 15 amp , fuse wire copper 100 amp , ht cable joint kit 3.5 core 95 x 52mm , holder angular , tape insulation tape pvc size 25mm x 25 mtr , switch piano 5 amps one way single pole , call bell buzzer , ceiling rose 5 amps , fan capacitor 2.5 mfd 240 v , pvc switch board 6 inch x 8 inch , pvc copper 2.5 sqmm single core multistand , pendent holder brass , coloured lamp 15w 240v red and green , switch board boxes 230 x 80 x 50mm , pvc switch board 4 inch x 7 inch , pvc switch board 4 inch x 4 inch , moudlar plate 6m , moudlar plate 4m , moudlar plate 3m , modular box 6m , modular box 4m , modular box 3m , modular blank space , modular switch socket combination box 5a , modular switch socket combination box 15a , socket modular 15a , socket modular 5a , socket 5 amps 5 pin multy purpose , tape insulation pvc size 50mmx25mtr , led lamp 3w b22cdl , led lamp retrofit 5 watt 240 volts , bell push modular 6a or 10a , pvc copper wire 6 sqmm , pvc cable insulated copper conductor 3 core x 70 oblique 0.0076 , modular switch 6a , modular socket 6a , modular switch 16a , modular socket 16a , exhaust fan steel body 300 mm , 2 feet x 2 feet ceiling light , 1 feet x 1 feet ceiling light , pvc aluminium 6 sqmm one core , lugs copper alloy 400 sqmm , copper lugs 70 sqmm , pvc aluminium 4 sqmm two core , pvc cable alusheathered weather proof twin flat 6 sqmm , lugs copper alloy 16mm , lugs copper alloy 25mm , lugs copper alloy 35mm , lugs copper alloy 50mm , lugs copper alloy 95mm , lugs copper alloy 120mm , lugs copper alloy 150mm , lugs copper alloy 185mm , lugs copper alloy 240mm , lt ug cable 3.5 core 25 sqm , acsr conductor , pvc aluminum cable single core 10 sqmm , lt line separator , water tank 500 ltr , water tank 1000 ltr , pvc bathroom cabinet mirror size 450 x 350mm , corner glass shelves , fuse wire copper 15 amp , veneer sheet 8 feet x 4 feet x 1mm white , galvanised mild steel wire cloth size 1mtr x 15mtr roll , cascade type ewc , gyser hot and cold stool connecting pipe , grating doom 125mm with hole , grating doom 125mm without hole , waste coupling sink 75mm , waste coupling sink 100mm , hinges 3 inch , hinges 4 inch , hexa blade , gi reducer elbow 15x20mm , oil putty , synthetic enamel paint superior tint , pink primer , red oxide primer , coal tar black paint , 600mmx450mm bevelled edge mirror , synthetic rubber adhesive in 1 ltr container , cp pillar cock , cp bib cock with flenge , cp angle cock with flenge , cp 2 way angle cock with flenge , concealed stop cock 15mm with flenge , stop cock regular body female thread , stop cock regular body male thread , centre hole basin mixture with out pop up waste system , hand shower with 1.5 mtrflaxible tube , corner glass self 200mm , plastic rawal plug 40mm long , shower 100mm dia round shape single flow , shower 100mm round shape single flow 1 5m easy flex tuble , bracket for whb , extention nipples 15mm x 50mm , hex nipple cp 15mm x 50mm , hydraulic door closer , door stopper , sliding door bolt aluminium 200mm , e board false ceiling size 60cmx60cmx4mm , glass panes 3mm , half threaded screw 35mm , full threaded screw 25mm , low plug 35mm , half threaded screw 25mm , door handle 150mm , sand coarse locally available , ditto but with waste hole of ptmt minimum weight 100 gms , wire nails of any size , aluminium extruded handle 100mm size , aluminium extruded barrel tower bolt 150mm , aluminium sliding door bolt 300mm long , glue for lime , 12mm thick particle board , 3mm thick glass panes , 5.5mm thick sheet glass shelf 12cm wide railing 60mm long , 15mm glavanised steel tubes medium grade , 20mm glavanised steel tubes medium grade , varnish finishing interior or exterior , french polish , distemper , 18mm pre laminated particle board grade 2 quality , exterior emulsion paint weather proof of 1st quality , painting brush 10cm flat size , painting brush 7.5cm flat size , painting brush 2.5cm flat size , lime unslaked fat lime , wooden screw 25mm to 40mm long size , wooden screw 15mm to 20mm long size , m seal 500 gm, 09 or 10 watt led bulb white, flexible wire copper twin core sheathed 40 0.076, pvc copper cable single core 2.5 sqmm, led focus light 15 watt, prospot cob swival led light 15 watt, ht cable end joint kit 95 sqmm, 05 watt led b22 bulb white, pvc copper 1.5 sqmm single core, heating element 2000 watt, pvc copper cable single core 4 sqmm, pvc cashing caping 25mm, pvc cashing caping 20mm, flexible wire copper twin core sheathed 23 0.076, moudlar plate 12m, modular box 12m, pvc copper cable single core 6 sqmm, db 8 way double door, decorative tipe led spot light 5w focus light 230v 50hz, led batten fitting 2 feet long, thermostat for geyser, pvc switch board rectangle 8 inch x12 inch, moudlar plate 8m, modular box 8m, fan regulator modular, pvc copper cable twin core 1.5 sqmm, ht fuse element 11000 volts 5 amps, ht fuse element 11000 volts 20 amps, ht fuse element 11000 volts 10 amps, ht cable jointing kit 3.5 corex95sqmm outdoor, switch socket combination 616 amp multi, switch socket combination 3 pin 15 amp, fuse wire copper 100 amp, ht cable joint kit 3.5 core 95 x 52mm, holder angular, tape insulation tape pvc size 25mm x 25 mtr, switch piano 5 amps one way single pole, call bell buzzer, ceiling rose 5 amps, fan capacitor 2.5 mfd 240 v, pvc switch board 6 inch x 8 inch, pvc copper 2.5 sqmm single core multistand, pendent holder brass, coloured lamp 15w 240v red and green, switch board boxes 230 x 80 x 50mm, pvc switch board 4 inch x 7 inch, pvc switch board 4 inch x 4 inch, moudlar plate 6m, moudlar plate 4m, moudlar plate 3m, modular box 6m, modular box 4m, modular box 3m, modular blank space, modular switch socket combination box 5a, modular switch socket combination box 15a, socket modular 15a, socket modular 5a, socket 5 amps 5 pin multy purpose, tape insulation pvc size 50mmx25mtr, led lamp 3w b22cdl, led lamp retrofit 5 watt 240 volts, bell push modular 6a or 10a, pvc copper wire 6 sqmm, pvc cable insulated copper conductor 3 core x 70 oblique 0.0076, modular switch 6a, modular socket 6a, modular switch 16a, modular socket 16a, exhaust fan steel body 300 mm, 2 feet x 2 feet ceiling light, 1 feet x 1 feet ceiling light, pvc aluminium 6 sqmm one core, lugs copper alloy 400 sqmm, copper lugs 70 sqmm, pvc aluminium 4 sqmm two core, pvc cable alusheathered weather proof twin flat 6 sqmm, lugs copper alloy 16mm, lugs copper alloy 25mm, lugs copper alloy 35mm, lugs copper alloy 50mm, lugs copper alloy 95mm, lugs copper alloy 120mm, lugs copper alloy 150mm, lugs copper alloy 185mm, lugs copper alloy 240mm, lt ug cable 3.5 core 25 sqm, acsr conductor, pvc aluminum cable single core 10 sqmm, lt line separator, water tank 500 ltr, water tank 1000 ltr, pvc bathroom cabinet mirror size 450 x 350mm, corner glass shelves, fuse wire copper 15 amp, veneer sheet 8 feet x 4 feet x 1mm white, galvanised mild steel wire cloth size 1mtr x 15mtr roll, cascade type ewc, gyser hot and cold stool connecting pipe, grating doom 125mm with hole, grating doom 125mm without hole, waste coupling sink 75mm, waste coupling sink 100mm, hinges 3 inch, hinges 4 inch, hexa blade, gi reducer elbow 15x20mm, oil putty, synthetic enamel paint superior tint, pink primer, red oxide primer, coal tar black paint, 600mmx450mm bevelled edge mirror, synthetic rubber adhesive in 1 ltr container, cp pillar cock, cp bib cock with flenge, cp angle cock with flenge, cp 2 way angle cock with flenge, concealed stop cock 15mm with flenge, stop cock regular body female thread, stop cock regular body male thread, centre hole basin mixture with out pop up waste system, hand shower with 1.5 mtrflaxible tube, corner glass self 200mm, plastic rawal plug 40mm long, shower 100mm dia round shape single flow, shower 100mm round shape single flow 1 5m easy flex tuble, bracket for whb, extention nipples 15mm x 50mm, hex nipple cp 15mm x 50mm, hydraulic door closer, door stopper, sliding door bolt aluminium 200mm, e board false ceiling size 60cmx60cmx4mm, glass panes 3mm, half threaded screw 35mm, full threaded screw 25mm, low plug 35mm, half threaded screw 25mm, door handle 150mm, sand coarse locally available, ditto but with waste hole of ptmt minimum weight 100 gms, wire nails of any size, aluminium extruded handle 100mm size, aluminium extruded barrel tower bolt 150mm, aluminium sliding door bolt 300mm long, glue for lime, 12mm thick particle board, 3mm thick glass panes, 5.5mm thick sheet glass shelf 12cm wide railing 60mm long, 15mm glavanised steel tubes medium grade, 20mm glavanised steel tubes medium grade, varnish finishing interior or exterior, french polish, distemper, 18mm pre laminated particle board grade 2 quality, exterior emulsion paint weather proof of 1st quality, painting brush 10cm flat size, painting brush 7.5cm flat size, painting brush 2.5cm flat size, lime unslaked fat lime, wooden screw 25mm to 40mm long size, wooden screw 15mm to 20mm long size, m seal 500 gm pack, pvc bracket plain for 20mm dia rod, pvc bracket angle for 20mm dia rod, fancy bracket plain for 25mm dia rod, fancy bracket angle for 25mm dia rod, centre support for 25mm dia rod, ms window peg stays long, rubber cill door bottom, stell peg set of six, designer wall floor laminates self adhesive of size 1mm thick, roller for paint, ppgi roof sheet corrugated, plain sheet, wooden beading, spindle no 3, spindle no 2, hasp and staple, f cistern washer, f cistern handle, bib cock washer all types, veneer board 8 feet x4 feet x 1mm


Agency / Dept : indian army
Tender Value : 1851750
Due Date : Apr 04, 2026