Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Air flow measuring valve Tenders List

Latest Air flow measuring valve Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Air flow measuring valve tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Air flow measuring valve tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Air flow measuring valve Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Air flow measuring valve tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Air flow measuring valve Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Air flow measuring valve Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Air flow measuring valve Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Air flow measuring valve tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Air flow measuring valve Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Air flow measuring valve sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Air flow measuring valve tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Air flow measuring valve tenders.

Is EMD mandatory for all Air flow measuring valve tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Air flow measuring valve work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Air flow measuring valve tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Air flow measuring valve Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15072929
Location : etah , uttar pradesh
Source : GEM Tenders

tender for boq cisf 0707 floating pump , 0707 high expansion foam generator , 0707 aluminium fire suit , 0707 suction hose 100mm , 0707 smoke blower cum exhauster. , 0707stretcher , 0707lifebuoy , 0707life jacket , 0707 celling hook , 0707fire beater , 0707ejector pump , 0707 hydraulic ram , 0707hydraulic cutter , 0707hydraulic spreader , 0707 medium expansion generator , 0706 co2 fire extinguisher 4.5kg , 0706 co2 fire extinguisher 6.5kg , 0706 dcpfire extin. cartridg type-06 kg , 0706 dcpfire extin. cartridg type-09 kg , 0707 branch london type, boq cisf, 0707 floating pump \nspecification--pump and engine specification \ncasing-powder coated anodized aluminum as per is\n617 impeller -bronze impeller 3. engine specification. engine shall meet applicable environmental norms and emission standard of govt. of india. 4 stroke air cooled petrol engine power output -not less than 5.9 hp ignition system -transistorized magneto starting system-recoil type of pump -single suction, centrifugal outlet -63 mm instantaneous water discharge-not less than 900 i or min delivery head-10 meter min water depth -25 mm of water discharge of solid-up to 15 mm size automatic float\ncontrolled throttle 4. fuel tank appropriate for continuous run of at least 1 hrs and should equipped\nwith fuel gauge. 5. float assembly hdpe shell or fiber glass with polyurethane foam.\n23outlet -63 mm instantaneous water discharge-not less than 900 i or min delivery head-10 meter min water depth -25 mm of water discharge of solid-up to 15 mm size automatic float controlled throttle 4. fuel tank appropriate for continuous run of at least 1 hrs and should equipped with fuel gauge. 5. float assembly hdpe shell or fiber glass with polyurethane foam, 0707 high expansion foam generator\nspecification - \nhigh expansion foam generator shall driven by water pressure and used for coverage for large spill of hydrocarbon liquids,total flooding of voluminous enclosure such as cable ducts and in accessible locations. it should be light weight, compact, suitable for groundoperation and easy movement. it should have arrangement for smoke extraction also. it should have pressure gauge of suitable rating at inlet for measuring pressure of water flow. a carrying handles and wheels should be provided for easy and smooth carriage.body -ss or frp materials to be specified by indentor 2. nozzle -gun metal 3. foam screen -ss 4. piping and foam inductor -light weight material with anti corrosive treatment 5. fan -fibre reinforced plastic - frp-or ss-material to be specified by indentor- 6. coupling -gun metal 7. foam duct -nylon or polythene - material to be specified by indentor- 6.0 dimension of the body - shell-and attachment- 1. depth -450 - 500 mm 2. width -900- 950 mm 3. height -900- 1000 mm 4. foam duct -10 meter long 5. smoke duct -10 meter long 6. coupling diameter -63 mm - instantaneous type- 7. maximum unit weight -50 kg, 0707 aluminium fire suit\nspecification - \nthe suit shall allow the wearer to expose himself and withstand point source approximately at 900 degc for 4-5 minutes, 700 degc for 15 minutes and 500 degc for 5 hours without adversely affecting the wearer .the fabrication of fire proximity or approach suit shall be made out of non-flammable, light weight, non-toxic flexible and heat reflecting material. the fabric shall be of impermeable aluminized coated oxidized penotex carbon fiber and shall have thermal insulation lining capable of resisting high temperature not less than 900 degc.max.wt-9.0 kg., 0707 suction hose 100mm\nspecification - \nsuction hose synthetic of 100 mm internal dia and length 2.5 mtr. confirming to is 3549 latest revision. it must be fully wire\nembedded suction hose, which can be used from suction side of the pump from source to pump in-let. the suction hose mostly\nbinded with copper wire with isi marked male and female threaded coupling as per is 902 - latest revision-and shall have 04 lugs.\nthe hose shall be subjected to an internal hydraulic pressure of 8 kg or cm2 for a period of three minutes and there shall be no sign of leakage or failure. the working vacuum shall be down to 635 mm of mercury without collapse. coupling must be tested for hydraulic pressure test at 21 kg or cm2 for a period of 02 minutes. the suction hose must be protected against oil, fungus, chemicals, acid and alkalis., 0707 smoke blower cum exhauster.\nspecification - \nit should be portable, high output smoke exhauster, petrol driven engine - 5.5 hp-and should be of size 18 inch or above. 2. it should be able to provide both positive and negative pressure ventilation to serve dual application i.e. as a blower as well as suction\nfor clearance of smoke or gases even in confined or closed non ventilated areas 3. the exhauster should be compact in dimension or size and should not measure more than 20 - height-x 20 - width-x 15 - depth-with a tolerance of + or -10 percent so that it can be\neasily placed in the fire tender compartment if so required. 4. the exhauster unit should be light in weight and weigh less than 35 kg with a tolerance of + or - 10 percent . 5. the exhauster should have high output airflow for effective de smoking operations. 6. the fan\nsize should be 18 diameter with many turbo blades to generate strong air force. 7. the dimensions should not exceed 18 inch in depth, 24 inch in width and 24 inch in height blade - - 18 diameter assembly should made up of aluminium or air flex fiberglass reinforced\npolyamide blades frame - - it should formed and welded sheet metal construction with powder -coat finish. grille - - should continuous circular wound external -weld steel wire with 4 tie points for additional safety - steel is zinc-plated with a clear\nchromate finish, 0707stretcher\nspecification - \nstretcher sl parameters value 1. unfolded size of the stretcher - l x w x h -not less than 201 x 53 x 13 - cm-with tolerance of +- 2 mm 2. number of folds which can be made not less than 02 3. material of the stretcher frame aluminium or powder coated mild steel 4. material of the support bed of the foldable stretcher vinyl coated nylon fabric or tetron canvas 5. the foldable stretcher shall fold lengthwise and cross wise and shall fold flat for compact storage and asy transportation yes 6. support bed of the foldable stretcher shall be stain and water resistant and easy to clean and antifungal yes 7. foldable stretcher shall have aluminium feet to prevent stretcher bed from touching the floor yes 8. aluminium poles shall have rubber hand grips to keep a firm grasp on the stretcher yes 9. minimum load carrying capacity of the foldable stretcher no less than 160 kg 10. weight of the foldable stretcher not more than 20 kg 11. foldable stretcher should have patient restrain strap with double locking quick release safety buckets yes 12. vertical hoisting sling to be provided yes, 0707lifebuoy\nspecification - 2. technical requirement- - a-the lifebuoy shall be irs approved. - b-lifebuoy shall be made up of, high visibility, impact resistant orange pe material filled with high density soft polyurethane - pu-foam which gives high floatability. - c-lifebuoy shall be provided with a grab line attached at four equally spaced points. - d-lifebuoy shall have solas retro- reflective tape stuck at four equally spaced places. - e-lifebuoy should be suitable for major application is rescue during floods and sea mishaps. - f-lifebuoy should have od 71 +- 1 cms,id 45 +- 1 cms. - g-lifebuoy should have buoyancy more than 17 kg. - h-lifebuoy shall be moisture proof and non-inflammable. 3. approvals- - a-lifebuoy shall be irs approved. - b-lifebuoy shall conforms to solas 74 as amended reg. iii or 4,iii or 7.1,iii or 34,x or 3 lsa code reg. i or 1.2 and ii or 2.1.1 imo resolution msc.81 - 70 - , msc. 200 - 80 - , msc.97 - 73-8.1,8.3., 0707life jacket\nspecification - \ntechnical requirement- - a-it shall be made up of high visibility nylon orange coloured cloth filled with high density soft polyethylene foam to provide high floatability. - b-jacket shall be provided with suitable plastic quick lock buckle and velcro for tightening. - c-irs approved water activated life jacket light should be provided with life jacket. - d-whistle shall be attached with jacket and solas approved retro- reflective tape stitched at visible locations covering a total area not less than 400cm. - e-it\nshall be suitable for major application is floods and sea or river mishaps. - f-life jacket shall have size not less than 68 x 42 x 10 cm. - g-floatability shall not be less than 16.5kgs. - h-weight of jacket shall not be more than 750gms - + or -100gm - ., 0707 celling hook\nspecification - \nspecification of fire hook standard is 927 - 2008 the function of fire hook is to pierce celling to allow the water on the upper floor to drain away, to pull down thatched roofs or roofs made out of matting, pulling out bales and bags of various commodities from a distance,opening and closing down of doors and various similar jobs technical features - material shall steel to be used for hook conform is 2004 - 1978 - handle shall be made of bamboo of length not less than 3 m - the edges shall be well shaped and finished - forgings shall be free from seams ,burrs cracks and other surface defect - hook shall be treated with suitable anti corrosive paint - hook shall be engaged to horizontal bar and weight of 140kg shall be applied vertically to the handle .the test hall be repeated ten times .the hook shall not bend and or or dent during the test. - standard is 927 - 2008 marking each hook shall be cleary and permanently marked with the following information - manufacturer s name or trade mark - size of handle - year of manufacture - marked with standard mark note - the equipment should be procured from the manufacturers - manufacturer needs to have all test or evaluation facility in house failing which the test evaluation should got done from govt. lab or govt. approved nabl accredited lab only - pre dispatch inspection-pdi clause is mandatory and to be incorporated at the time of indent of above fire equipment. the cisf representative for inspection or pdi shall be detailed by fire directorate new delhi, standard is 8096 - 1992 fire beaters are often used for putting off small fires such as wild grass, shrubs, dry vegetation, hay, plastic, coal which can be easily put out by beating and smothering. this piece of equipment finds much application in rural areas and in those places where there is a scarcity of water components 1. handle - i-the handle shall be made of solid bamboo having 1800 mm length and 30 + 5 mm diameter or of some alternative material of heat insulate properties provided. the handle shall be finished smooth. - ii-the handle before fitting into the socket made in shank shall be liberally swabbed with termite resistant composition comprising 10 percent solution of acid-chromate composition in water. it will then be allowed to dry for at least 24 hours. - iii-the free end of the bamboo handle shall be protected from disintegrating by fitting with a hollow close ended cap made of chrome plated mild steel or aluminium. the protective cap shall have knurling made on its outer surface to enhance grip at least 5 mm of the round edges of this knurled protective cap shall be chamfered all round at 45 degree to reduce sharpness 2. blade the blade of the fire beater shall consist of a rectangular piece of expanded mild steel or steel or steel wire mesh measuring 452 mm x 352 mm, covered fully on both sides with stretched fire resistant canvas olive green in colour placed between two frames and securely fixed in position with hexagonal nut-bolts using spring washers all-round the frame the two pieces frame shall be made of 1 mm thick mild steel. the width of frame shall be 30 mm. the shank portion of the blade shall also be in two pieces made of 1 mm thick spring steel. the frame shall be welded at diagonals as per is 819-1957 assembling the blade so made shall be fixed with bamboo handle through a two piece shank. the socket part of the shank shall be tightly screwed to the bamboo handle by two bolts, nu, 0707ejector pump\nspecification - \nspecification 1. material of construction -aluminium alloy 2. maximum working pressure -10kg or cm2 3. minimum working pressure -5kg or cm2 4. test pressure -21kg or cm2 5. inlet diameter -100 mm - is - 902 - , male round threaded 6. outlet diameter -100 mm - is - 902 - , male round threaded 7. inst. inlet -63 mm - is - 903-instantaneous male 8. discharge -650lpm at 7kg or cm2 9. max suction depth -10 meters, 0707 hydraulic ram\nspecification - \n4. hydraulic spreader sl parameters value 1. conformity to standards as per nfpa 1936 with latest amendment 2. dimensions - lxbxw- - mm-not more than 900 x 285 x 250 - + 10 percent -3. working pressure in bar 700 4. highest spreading force not less than 650 kn 5. lowest spreading force not less than 40 kn 6. spreading distance not less than 300 mm 7. pulling distance not less than 300 mm 8. highest pulling force kn not less than 34 kn 9. lowest pulling force - lpf-not less than 27 kn 10. weight including battery not more than 20 kg 11. replaceable blade of cutter yes 12. type of teeth of blade straight 13. material of blade of cutter dropped forged special steel alloy 14. material of hinges, pin, lever for protection against corrosion heat treated tool steel. 15. material of tool body to ensure less weight high quality thermoplastic 16. material of arm spreader high alloy forged light metal 17. operating temperature range -25 degc to +55 degc 18. type of battery preferably lithium ion based rechargeable 19. minimum charging time of battery not more than 120 min 20. connector to connect the tool to any 220 v power source , yes, 0707hydraulic cutter\nspecification - \ntechnical specification or data -- hydraulic cutter should have the following specifications. a cutting force upto not less than 690 kn b capable of cutting round bar not less than 40mm dia steel rod of 500 550 mpa strength c blade opening at tips not less than 200 mm. d weight not more than 20 kg accessories -- 01. tool kit for changing curved and straight blades with spare blade. 02. connecting hoses of at least 5 meter for connecting pumps. 03. compatible pumps to achieve above mention performance of equipments., 0707hydraulic spreader\nspecification - \nsl parameters value 1. conformity to standards as per nfpa 1936 with latest amendment 2. dimensions - lxbxw- - mm-not more than 900 x 285 x 250 - + 10 percent- 3. working pressure in bar 700 4. highest spreading force not less than 650 kn 5. lowest spreading force not less than 40 kn 6. spreading distance not less than 300 mm 7. pulling distance not less than 300 mm 8. highest pulling force kn not less than 34 kn 9. lowest pulling force - lpf-not less than 27 kn 10. weight including battery not more than 20 kg 11. replaceable blade of cutter yes 12. type of teeth of blade straight 13. material of blade of cutter dropped forged special steel alloy 14. material of hinges, pin, lever for protection against corrosion heat treated tool steel. 15. material of tool body to ensure less weight high quality thermoplastic 16. material of arm spreader high alloy forged light metal 17. operating temperature range -25 degc to +55 degc 18. type of battery preferably lithium ion based rechargeable 19. minimum charging time of battery not more than 120 min 20. connector to connect the tool to any 220 v power source , yes, 0707 medium expansion generator\nspecification - \nfoam expansion ration within the range of 1 - 300 to 1 - 600.foam output lpm-100-150 m3 or min weight-weight within the range of 20 kg to 25 kg inlet water pressure - bar-- 8 to 10 smoke exhauster-100-120 m3 or min at 08 to 10 bar inlet pressure material of construction-body or shell -s.s - 304 grade - , nozzle-g.m, foam screen-knitted fabric or s.s, fan - ,alloy aluminum, turbine-g.m., foam duct - 30 m long-- polythene, carrying handle and stand-s.s, smoke trunk-7.5 mtrs. long special construction., as per is 15683 - 2018 -with\nlatest amendments - 1. type of extinguisher isi marked stored pressure type co2 4.5 kg capacity\nfire extinguisher, conforming to is 15683 - 2018 -with latest amendments - .2. extinguishing media carbon dioxide based - as per is 15222 - 3. expelling medium co2 extinguishing medium. 4. type of extinguisher high pressure extinguisher - service pressure greater than 19 bar- 5. feature of fire extinguishers yes, safety devices - mandatory for high pressure extinguisher - , rechargeable andcarrying handle and hose assembly is mandatory as per clause no. 9.3 and 9.8 of is 15683-2018. 6. class of fire for which fire extinguisher is suitable. class-b and c 7. minimum effective discharge time-minimum 8 sec - as per 7.2.2 of is 15683 - 2018- 8. material specification for the body of highpressure extinguisher- steel body - as per latest is 7285- 9. carbon dioxide based fire extinguisher capacity in kg. 4.5 kgs. 10. operating temperature temperature range as mentioned in clause no.7.1of is 15683 - 2018. 11. fire ratings of different class of fires-minimum 34b - higher acceptable- general parameters- - according to is 15683 - 2018 - latest amendment-- 1. conformity to standard is-15683-2018 - latest amendments- 2. bis marking yes 3. availability of test report from central govt. or nabl or ilac accredited lab to prove conformity to specification availability of test report from central govt. or nabl accredited laboratory. additional technical parameters- 1. marking required as per clause 10.2 of is 15683 - 2018 2. valve high pressure control valve as per is-3224 bearing isi mark and peso - ccoe - , nagpur approved. 3. test report and peso or bis certificate- a-test reports from central govt. or nabl accredited laboratory shall be submitted along with supply otherwise material shall be rejected. b-peso - formerly ccoe - , nagpur approval certific, 0706 co2 fire extinguisher 6.5kg\nspecification - \nspecification for co2 6.5 kg capacity fire extinguisher - trolley mounted- isi marked 6.5kg capacity\nco2 trolley mounted portable fire extinguisher confirming to is - 16018-2012 having typical shape, showing the cylinder, concave base shall be completed with following -- technical data 1. temperature working range shall be -300 c to +550 c 2. co2 fire extinguisher should be as per is-16018 - latest revision - . with isi mark. 3. filled carbon dioxide gas shall be as per is-15222 - latest revision - . 4. extinguisher should be provided with ms trolley with solid rubber wheels, handle, control discharge m e c h a n i s m with discharge hose, rubber grip, hanging clamp and n o n metallic discharge horn. 5. the minimum bursting pressure of discharge hose - wire braided-shall be 275 bar. 6. extinguisher should be class b, c and electrical fires, fire rating 55b. 7. seamless cylinder should be as per is 7285 - latest revision-with isi mark and should be approved by peso. 8. discharge valve should be wheel type as per is 3224 - latest revision-with isi mark. 9. safety device should be as per is 5903 and safety device conforming to is-5903 - latest revision-shall be in-built in discharge valve conforming to is-3224. 10. siphon tube should be of brass alloy no. 2 as per is 407. 11. finishing of paint shall be with po red as per is-5 - shade 538- 12. inspection and testing of the extinguisher shall be as per approved qap, fire extinguisher, as per is 15683 - 2018 -with latest amendments - 1. type-cartridge type with 01 spare\ncartridge 2. extinguishing media-powder based as per is - 4308 or abc powder conforming to is - 4308 3. expelling medium or agent-n2 based - stored pressure 4. type of extinguisher-low pressure extinguisher - service pressure 19 bar- 5. feature of fire extinguishers-carrying handle and hose assembly is mandatory as per clause no. 9.3 and 9.8 of is15683-2018 6. class of fire for which fire extinguisher is suitable- class-a, b and c 7. minimum effective discharge time-minimum 13 sec - as per 7.2.1.1 of is 15683 - 2018- 8. material specification for the body of lowpressure extinguisher- welded low carbon steel cylinders as per clause no. 9.2.5 of is -1568 9. powder based extinguishing media-abc - mono ammonium phosphate 90 percent- 10. powder based fire extinguisher capacity in kg-06 kgs. 11. operating temperature -degc-- temperature range as mentioned in clause no.7.1 of is 15683 - 2018 12. fire ratings of different class of fires 3a, 89b - minimum- general parameters- - according to is 15683 - 2018 - latest amendment- 1. conformity to standard is-15683-2018 - latest amendments- 2. bis marking yes 3. availability of test report from central govt. or nabl or ilac accredited lab to prove conformity to specification availability of test report from central govt. or nabl accredited laboratory additional technical parameters 1. marking-required as per clause 10.2 of is 15683 - 2018 2. test reports test reports from central govt. or nabl accredited laboratory shall be submitted along with supply otherwise material shall be rejected. 3. bis certificate-valid bis approval certificate - is15683 - 2018-consisting cml license number shall be submitted along with offer. 4. painting-body of the fire extinguisher shall be painted withp.o. red color conforming to shade no. 536 or, fire extinguisher, as per is 15683 - 2018 -with latest amendments- 1. type-cartridge type\nwith 01 spare cartridge 2. extinguishing media-powder based as per is - 4308 or abc powder conforming to is - 4308 3. expelling medium or agent-n2 based - stored pressure- 4. type of extinguisher-low pressure extinguisher - service pressure 19 bar- 5. feature of fire extinguishers-carrying handle and hose assembly is mandatory as per clause no. 9.3 and 9.8 of is15683-2018 6. class of fire for which fire extinguisher is suitable- class-a, b and c 7. minimum effective discharge time-minimum 13 sec - as per 7.2.1.1 of is 15683 - 2018- 8. material specification for the body of lowpressure extinguisher- welded low carbon steel cylinders as per clause no. 9.2.5 of is - 15683 9. powder based extinguishing media-abc - mono ammonium phosphate 90 percent- 10. powder based fire extinguisher capacity in kg-06 kgs. 11. operating temperature -degc-- temperature range as mentioned in clause no.7.1 of is 15683 - 2018 12. fire ratings of different class of fires 3a, 89b - minimum- general parameters- - according to is 15683 - 2018 - latest amendment-- 1. conformity to standard is-15683-2018 - latest amendments- 2. bis marking yes 3. availability of test report from central govt. or nabl or ilac accredited lab to prove conformity to specification availability of test report from central govt. or nabl accredited laboratory additional technical parameters- 1. marking-required as per clause 10.2 of is 15683 - 2018 2. test reports test reports from central govt. or nabl accredited laboratory shall be submitted along with supply otherwise material shall be rejected. 3. bis certificate-valid bis approval certificate - is15683 - 2018-consisting cml license number shall be submitted along with offer. 4. painting-body of the fire extinguisher s, 0707 branch london type\nspecification - \nmultipurpose nozzle 500 lpm 1. technical requirements- - a-flow rate - selectable-- 150-250-350-500 lpm. - b-light in\nweight and easy to handle. - c-weight of the nozzle - 2.5 kg. - d-the calibrated flow rates are easily selectable through an indexed ring and the maximum rate is indicated by a raised lug. - e-the stream patterns are also changed by rotating the diffuser head ring with tactile marking - straight jet, spray and fog - . - f-nozzle should have flush feature for flushing any foreign items like wood or stone etc. - g-nozzle should also have metal partitions inside to restrict entry of foreign particle of bigger size. - h-nozzle should be having pistol grip, shut off ball valve opening and made of aluminium alloy. - i-nozzle shall meet the operational requirement as per en standard. - j-the head is protected with polyurethane bumper guard. the elastomers of bumper guard does not melt under heat. the teeth of nozzle should be of steel. - k-it should be of pok or elkhart or akron or rosenbaur make. - l-nozzle should have 3 stream pattern - straight jet, flash over and wide angle fog- - m-fog angle should be 130 degree. - n-inlet of the nozzle should of swivel inlet to avoid any kinking of hose 2. warranty-warranty - 1 years. service warranty - 5 years 3. pre dispatch inspection- - a-pre dispatch inspection shall be carried out at vendor s or oem site where all testing facilities as per relevant standard are available.


Tender Value : 3614370.28
Due Date : May 02, 2026
T18 Ref No : 15015516
Location : aligarh , uttar pradesh
Source : GEM Tenders

corrigendum tender for title1 , title2 , title3 , title4 , title5 , title6 , title7 , title8 , title9 , title10 , title11 , title12 , title13 , title14 , title15 , title16 , title17 , title18 , title19 , title20 , title21 , title22 , title23 , title24 , title25 , title26 , title27 , title28 , title29 , title30 , title31 , title32 , title33 , title34 , title35 , title36 , title37 , title38 , title39 , title40 , title41 , title42 , title43, toshiba spares, generator steady bearing metal, ring gasket 3 mm compressed non asbestos gasket for blank plate connection stator cooling water line to funnel cl150 asme 16.5 rf dia 65, full face gasket 3 mm compressed non asbestos gasket for bird wire mesh installation scw skid vent cl150 asme 16.5 rf dia 40, full face gasket 3 mm compressed non asbestos gasket emergency seal oil pump discharge nozzle connection cl150 asme 16.5 rf dia 65, full face gasket 3 mm compressed non-asbestos gasket seal oil pump discharge piping regulating valve 10mkw22aa003 connection cl150 asme 16.5 rf dia 65, full face gasket 3 mm compressed non asbestos gasket seal oil pump discharge relief valve 10mkw10aa401 connection cl150 asme 16.5 rf dia 65, full face gasket 3 mm compressed non asbestos gasket seal oil pump discharge relief valve 10mkw20aa001 connection cl150 asme 16.5 rf dia 65, ring gasket 3 mm compressed non asbestos gasket for flow element connection seal oil pump suction piping cl150 asme 16.5 rf dia 65, full face gasket 3 mm compressed non asbestos gasket for strainer connection seal oil pump suction piping cl150 asme 16.5 rf dia 80, full face gasket 3 mm compressed non asbestos gasket pump discharge nozzle connection cl150 asme 16.5 rf dia 80, full face gasket3 mm compressed non asbestos gasket for seal oil pump suction nozzle connection cl150 asme 16.5 rf dia 100, full face gasket 3 mm compressed non asbestos gasket for manholes air detraining section cl150 asme 16.5 rf dia 450, full face gasket 3 mm compressed non asbestos gasket for butterfly valve connection stator cooling water line to funnel cl150 asme 16.5 rf dia 65, insulating gasket insulating type gasket kit along with fastners for duplex oil strainer outlet connection seal oil pump discharge piping cl150 asme 16.5 rf dia 65, ring gasket 3 mm compressed non asbestos gasket for stator cooling water line to generator and from generator cl150 asme 16.5 rf dia 150, ring gasket 3 mm compressed non asbestos gasket for h2 gas pressure regulator valve connection cl150 asme 16.5 rf dia 15, ring gasket 3 mm compressed non asbestos gasket for stator cooling water line from generator cl150 asme 16.5 rf dia 200, ring gasket 3 mm compressed non asbestos gaske for drain line air detraining section cl150 asme 16.5 rf dia 25, ring gasket 3 mm compressed non asbestos gasket for vent line scw skid storage tank cl150 asme 16.5 rf dia 25, ring gasket 3 mm compressed non asbestos gasket for blank plate connection stator cooling water line to funnel cl150 asme 16.5 rf dia 65, ring gasket 3 mm compressed non asbestos gasket for break up flange connection seal oil pump suction piping upstream of strainer cl150 asme 16.5 rf dia 80, ring gasket 3 mm compressed non asbestos gasket for break up flange connection seal oil pump discharge piping downstream of regulating valve cl150 asme 16.5 rf dia 80, ring gasket 3 mm compressed non asbestos gasket for break up flange connection seal oil make up air detraining section cl150 asme 16.5 rf dia 80, nitrile rubber o ring for duplex oil strainer basket covers refer note 2 special grooved flange dia 65, rectangular o ring gasket nitrile rubber ring gasket square cross section for break up flange connection duplex oil strainer outlet to generator piping dia 65, rectangular o ring gasket nitrile rubber ring gasket square crosssection for seal drain nozzle connection air detraining section dia 80, rectangular o ring gasket nitrile rubber ring gasket square crosssection for break up flange connection from generator to h2 detraining section exciter side dia 125, rectangular o ring gasket nitrile rubber ring gasket square crosssection for break up flange connection from generator to h2 detraining section turbine side dia 125, rectangular o ring gasket nitrile rubber ring gasket square crosssection for h2 detraining section connection from generator to h2 detraining section exciter side dia 125, rectangular o ring gasket nitrile rubber ring gasket square crosssection for h2 detraining section connection from generator to h2 detraining section turbine side dia 125, rectangular o ring gasket nitrile rubber ring gasket square crosssection for break up flange connection bearing 10 oil drain piping special grooved flange dia 250, rectangular o ring gasket nitrile rubber ring gasket square crosssection flange connection for cleaning air detraining section special grooved flange dia 300, rectangular o ring gasket nitrile rubber ring gasket square crosssection for break up flange connection bearing 9 oil drain piping special grooved flange dia 300, rectangular o ring gasket nitrile rubber ring gasket square crosssection for break-up flange connection generator co2 gas piping special grooved flange dia 50, rectangular o ring gasket nitrile rubber ring gasket square crosssection for break up flange connection generator h2 gas piping_special grooved flange dia 50, rectangular o ring gasket nitrile rubber ring gasket square crosssection for float trap valve connection special grooved flange dia 50, rectangular o ring gasket nitrile rubber ring gasket square crosssection for body cover flange connection float trap special grooved flange dia 500, ring gasket 3 mm compressed non asbestos gasket for orifice connection seal oil pump discharge piping cl150 asme 16.5 rf dia 65, ring gasket 3 mm compressed non-asbestos gasket for flow element connection seal oil pump discharge piping cl150 asme 16.5 rf dia 65, ring gasket 3 mm compressed non asbestos gasket for duplex oil strainer inlet connection seal oil pump discharge piping cl150 asme 16.5 rf dia 65, ring gasket 3 mm compressed non asbestos gasket for break up flange connection seal oil make up from air detraining section hma cl150 asme 16.5 rf dia 200, ring gasket 3 mm compressed non asbestos gasket for bird wire mesh connection air detraining section atm piping gbv cl150 asme 16.5 rf dia 200, spring tension measurement tool for generator carbon brushes for toshiba make 660mw generator drawing no. 2kc116665


Tender Value : 3748250
Due Date : Apr 18, 2026