Search Tenders
Filters
Reset All
T18 Ref No
All States
All Cities
All Agencies
Tender ID
Due Date
Tender Value
Tender Source
Tender Type

18Latest Air drier repair Tenders List

Latest Air drier repair Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Air drier repair tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Air drier repair tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Air drier repair Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Air drier repair tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Air drier repair Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Air drier repair Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Air drier repair Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Air drier repair tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Air drier repair Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Air drier repair sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Air drier repair tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Air drier repair tenders.

Is EMD mandatory for all Air drier repair tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Air drier repair work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Air drier repair tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Air drier repair Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 16188914
Source : GEM Tenders
LIVE TENDER
tender for round the clock operation and preventive maintenance work , dismantling and shifting of asp , shifting of overhauled or new asp , oh of asp , dismantling and shifting of coarse ash pump , shifting of overhauled or new coarse ash pump , oh of coarse ash pump , dismantling and shifting of vp , shifting of overhauled or new vp , manpower assistance for oh of vp , manpower assistance for servicing of iac , manpower assistance for servicing of tac , oh of esp blower , oh of im and terminal silo blower , oh of im and terminal silo vent air fan , oh or servicing of hmdc , oh or servicing of rotary feeder , dismantling and shifting of balp or fwp or fahp or bahp or eco pump or hcsd pump , shifting of overhauled or new balp or fwp or fahp or bahp or eco pump or hcsd pump , oh of fwp , oh of balp pump , oh of fahp pump , oh of bahp pump , oh of economizer pump , oh of hmdc pump , oh of hp swp , oh of lp swp , oh of baofp , oh of rwp , oh of ahp clarifier sludge pump , oh of dosing pump , oh of awrp , oh of rpswp , oh of drain pump , oh of baha jet type drain pump , manpower assistance for fc of asp , manpower assistance for fc of coarse ash pump , oh of gb of asp , oh of gb of coarse ash pump , oh of lop of fc of asp , servicing of oc of fc of asp , servicing of tds of clarifier , alignment of asp , rotation of as disposal line , rotation of ba discharge pipe line , replacement of ms pipe line dia 250 nb to 350 nb , replacement of ci pipe line dia 200 nb to 250 nb , ash disposal by dumper or trolley to outside power house , servicing of dewatering pump , servicing of submersible pump , removal of wornout or damage valves , inatallation of new or repaired valves , replacement of spout , pipe laying and alignment of ms pipe 406.4mm , refractory works in bah , providing shuttering to carry out the refractory work , fabrication and erection of anchor of bah , scaffolding work in bottom ash hopper , isolation of bottom ash hopper , hiring of 01 no. jcb or compact loader bobcat , manpower assistance for oh or servicing of drier, round the clock operation routine and preventive mechanical maintenance of ahd, round the clock operation routine and preventive mechanical maintenance and housekeeping and cleaning works of complete ash handling plant of 2x660mw ctps obra, sonebhadra., dismantling and shifting of ash slurry pump from its foundation to maintenance bay, shifting of overhauled new ash slurry pump from maintenance bay to the foundation of pump, complete overhauling of ms indure make ash slurry pumps, dismantling and shifting of coarse ash pump from its foundation to maintenance bay, shifting of overhauled new coarse ash pump from maintenance bay to the foundation of pump, complete overhauling of ms indure make coarse ash pump, dismantling and shifting of vacuum pumps from its foundation to maintenance bay, shifting of overhauled new vacuum pumps from maintenance bay to the foundation of the pump, providing manpower assistance for overhauling of vacuum pumps in presence of oem ta make vacuunair aeromatic capacity 3871 cubic meter per hour, providing manpower assistance for servicing of instrument air compressor with drier in presence of oem ta make atlas copco capacity 1300 cubic meter per hour, providing manpower assistance for servicing of transport air compressor in presence of oem ta make atlas copco capacity 8250 or 7500 cubic meter per hour, complete overhauling of esp fluidizing air blower make model rh 120ac capacity 660 cubic meter per hour, complete overhauling of im and terminal silo aeration blower fluidizing air blower make model rhh 20wc capacity 1400 cubic meter per hour, complete overhauling of im and terminal silo vent air fan type centrifugal make ms maxim air, complete overhauling or servicing of hmdc installed at im and terminal silo, complete overhauling or servicing of rotary feeder installed in im and terminal silo tank, dismantling and shifting of balp or fwp or fahp or bahp or eco. pump or hcsd pump from its foundation to maintenance bay, shifting of overhauled or new balp or fwp or fahp or bahp or eco. pump or hmdc pump from maintenance bay to the foundation of the pump, overhauling of flushing water pump fwp, overhauling of bottom ash low pressure pump balp, overhauling of fly ash high pressure pump fahp, overhauling of bottom ash high pressure pump bahp, overhauling of economizer pump, overhauling of hydro mix dust conditioner pump hmdc for im and terminal silo, overhauling of hp seal water pump, overhauling of lp seal water pump, overhauling of bottom ash overflow pump baofp, overhauling of recycle water pump rwp, overhauling of ahp clarifier sludge pump, overhauling of alum lime and poly electrolyte dosing pump, overhauling of ash water recovery pump, overhauling of recovery pump seal water pump, overhauling of drain pumps installed at ba hopper area ash slurry pump house vacuum pump area silo area and recovery clarifier area., overhauling of bottom ash hopper area jet type drain pump, providing manpower assistance for overhauling of fluidomat make fluid coupling model sc 10 300kw or 1480 rpm motor of ash slurry pump in presence of oem ta, providing manpower assistance for overhauling of fluidomat make model sc 8 50kw or 1480 rpm motor speed variation +20 to -20 percentage fluid coupling of course ash pump and clinker grinder drive assembly in presence of oem ta, overhauling of new allen berry works make gear box of ash slurry pump model csa250 260kw or 1150 rpm, overhauling of new allen berry works make gear box of coarse ash pump and clinker grinder drive assembly model csa125 55kw or 1500 rpm, overhauling of lube oil pump of fluid coupling of ash slurry pump, servicing of oil cooler of fluid coupling of ash slurry pump, complete servicing of turbo driving system of clarifier, alignment of ash slurry pump, rotation of ash slurry disposal lines 400x 9.5mm thk nb, rotation of bottom ash discharge pipe line 200 nb, replacement of ms pipe line dia 250 nb to 350 nb, replacement of ci pipe line dia.200 nb to 250 nb, in case the huge quantity of ash accumulated at esp or im silo or terminal silo floor the same shall be segregated and lifted by dumper or trolley to outside powerhouse boundary for its disposal of 2x660mw ctps. one dumper equal to two tractor trolley, complete servicing of dewatering pump., servicing of goodwin make submersible pump of capacity 200 cubic meter per hour mechanical work, removal of worn out or damaged valves of size more than 80mm nb from ash disposal line or seal water line or ash water line etc., installation of new or repaired valves of size more than 80mm nb in ash disposal line or seal water line or ash water line etc., replacement or repairing of spout of im silo or terminal silo, pipe laying and alignment of following diameter ms pipe over the rcc pedestal of height approx. varies from 300 to 1500mm which includes transportation of pipe and its accessories at erection site including cutting, grinding as well as its welding tightening of coupling clamping bolt and nuts gasket etc. including testing as per recommendation of field quality plan satisfactory hydraulic testing commissioning etc. required for proper completion of work including cost of all labour material t and p etc. erw ms pipe od 406.4mm near im silo area, refractory works in bottom ash hopper, providing shuttering to carry out the refractory work, fabrication and erection of anchor of bah, scaffolding work in bottom ash hopper, isolation of bottom ash hopper, hiring of 01 no. jcb or compact loader bobcat, providing manpower assistance for overhauling or servicing of drier in presence of oem ta make ms mellcon job no csu 58 i
T18 Ref No : 16239962
Location : pune , maharashtra
Source : GEM Tenders
LIVE TENDER
tender for with 2000 lumen , rewinding of ceiling fan motors with sweep up to 1400 mm , rewinding of exhaust fan motors with sweep up to 450 mm , rewinding of pedestal fan motors with sweep up to 450 mm , replacement of faulty 100 watt, two module, 5 step electronic fan regulator on the existing switchboard , replacement of faulty piano switch 5 or 6 amp on the existing switchboard , replacement of faulty 3 pin 5 or 6 amp socket outlet on the existing switchboard , replacement of faulty 6 pin 15 or 16 amp socket outlet on the existing switchboard , replacement of faulty 5 to 32 a, c curve sp mcb in the existing mcb db , replacement of faulty 5 to 32 a, c curve dp mcb in the existing mcb db , refilling of existing 4.5kg, co2 type fire extinguisher , repairing of faulty compound light with provision of high performance cool daylight 40 watt led bulb, and 2 x 1.5 sq mm cu cond. cable , supplying and laying 25mm x 5mm gi strip at 0.50 metre below ground , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty on and off push button , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty overload relay , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty on delay timer , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty pla relay i , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty connector for power terminal , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty thermostat , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hand shut off valve , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty drier filter , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty safety pressure relief valve , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hp gauge , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty lp gauge , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hp cutout , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty lp cutout , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty 25 a 415 v tp contactor, mnx25, ac3 rating suitable for din rail mount , repair of 7 tr singhson package ac unit by nitrogen pressure testing, leak rectification, flushing, brazing or flaring, vacuuming, purging, leak-proofing , supplying and charging or topping of r 22 refrigerant gas , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty, ocm of ems at te bldg and staff qtrs at chd pune sh attending defects at rnc, supplying and fixing of led indicators red, yellow, blue or green of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels etc as reqd., supplying and fixing of ac ammeter 0 to 200a class 1, analog 96mm size of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd, supplying and fixing of ac voltmeter 0 to 500v class 1, analog 96 mm of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd., supplying and fixing of hn type 63 a fuse link compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd., supplying and fixing of voltmeter selector switch of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd., supplying and fixing of 100 a, 415 v, 4 pole isolator of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd., servicing and repairing of 800 a, air circuit breakers of c and s make including draw out from panel cleaning of jaw contact and arc chut by using crc or wd40, proper alignment, testing etc as reqd., repairing and calibration of existing apfc relay of syntron make for 135 kvar capacitor panel including auto mode operation and on load testing etc complete as reqd., attending oil leakage of 22kv, 500kva transformer voltamp make, with highgrade oil resistant nitrile or rc70c neoprene bonded cork gaskets incl. supply and top up of 10 ltr of ehv grade mineral oil., carrying out repair or replacement of llop switch suitable for existing 500 kva ea set of greaves make with installation, connection, testing, commissioning as reqd., carrying out repair or replacement of water temperature switch suitable for existing 500 kva ea set of greaves make with installation, connection, testing, commissioning as reqd., carrying out repair or replacement of digital rpm cum hour meter suitable for existing 500 kva ea set of greaves make with installation, connection, testing, commissioning as reqd., carrying out repair or replacement of brass battery terminal with copper lugs for 1 battery with installation, connection, testing, commissioning as reqd., attending leakage in exhaust silencer flexible bellow with brazing or repairing or replacement of existing 500 kva ea set of greaves make etc as reqd., carrying out repair or replacement of charging alternator incl. replacement of components or rewinding of existing 500 kva ea set of greaves make with inst., connection, testing, commissioning etc., attending engine oil leakage of top head and rocker cover engine, fuel pump, tank, fuel valves of 500 kva greaves dg set having engine model tbd 4iv12p, with all genuine greaves cotton spares etc., carrying out servicing, chemical descaling and high-pressure jet cleaning of the radiator of 500 kva dg set incl. dismantling radiator, replacement of rubber hoses and clamps, coolant top up etc., repairing, rewinding of 7.5hp beacon make centrifugal pump set incl. greasing, varnishing, replac. of wornout bearings and gland packing incl. dismantling, handling, transp. and reinstallation etc., replacement of faulty foot valve with a 40 mm dia heavy duty brass foot valve, with all accessories including testing commissioning etc complete as required, repairing of 1.5 tr split ac units by replacement or repair of blower motor for indoor unit of voltas make with connections, testing, commissioning etc as reqd., repairing of 1.5 tr split ac units by attending of leakage incl. brazing or flaring the leak points, vacumising, purging flushing and supplying and charging of r22 or r410 or r134 refrigerant gas etc, supply and fixing 20 watt aluminium led batten tubelight with 2000 lumen for commercial use on wall or ceiling incl. testing commissioning etc complete as required, rewinding of ceiling fan motors with sweep up to 1400 mm, including replacement of worn out bearings, shaft, bush, capacitor, greasing, varnishing, taping, insulation, testing, commissioning as reqd, rewinding of exhaust fan motors with sweep up to 450 mm, including replacement of worn out bearings, shaft, bush, capacitor, greasing, varnishing, taping, insulation, testing, commissioning as reqd., rewinding of pedestal fan motors with sweep up to 450 mm, including replacement of worn out bearings, shaft, bush, capacitor, greasing, varnishing, taping, insulation, testing, commissioning as reqd., replacement of faulty 100 watt, two module, 5 step electronic fan regulator on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty piano switch 5 or 6 amp on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 3 pin 5 or 6 amp socket outlet on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 6 pin 15 or 16 amp socket outlet on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 5 to 32 a, c curve sp mcb in the existing mcb db including connections, testing and commissioning as reqd., replacement of faulty 5 to 32 a, c curve dp mcb in the existing mcb db including connections, testing and commissioning as reqd., refilling of existing 4.5kg, co2 type fire extinguisher including to and fro transportation including replacing faulty horn, hose pipe, hydraulic pressure testing, cleaning, labelling etc. as reqd., repairing of faulty compound light with provision of high performance cool daylight 40 watt led bulb, and 2 x 1.5 sq mm cu cond. cable from pole junction box to fitting etc. complete as reqd., supplying and laying 25mm x 5mm gi strip at 0.50 metre below ground as strip earth electrode, including connection with gi nut, bolt, spring washer etc. as required., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty on and off push button including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty overload relay including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty on delay timer including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty pla relay including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty connector for power terminal including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty thermostat including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hand shut off valve including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty drier filter including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty safety pressure relief valve including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hp gauge including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty lp gauge including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hp cutout including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty lp cutout including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty 25a 415v tp contactor, mnx25, ac3 rating suitable for din rail mount incl. wiring, connection, testing as reqd, repair of 7 tr singhson package ac unit by nitrogen pressure testing, leak rectification, flushing, brazing or flaring, vacuuming, purging, leak-proofing, testing and commissioning etc as reqd, supplying and charging or topping of r 22 refrigerant gas in existing 7 tr package ac units etc compete as required, repair of 7tr conventional package ac unit of singhson make by replacement of the faulty condenser fan motor 1 phase, 0.5hp motor including wiring, connections, testing, commissioning etc as reqd.
T18 Ref No : 16239964
Location : pune , maharashtra
Source : GEM Tenders
LIVE TENDER
tender for distribution panel , supply,replacement and fixing multifunction or intelligent meter in mv, lt,mv,lt, distribution panel , supply, replacement and fixing 10 kvar capacitor type md02 in existing mv, lt, distribution panels , supply, replacement and fixing ac voltmeter 0-600v class1.0, 144 sq. mm. in existing panels , supply, replacement and fixing ac ammeter, 0 to 600 amp class 1.0, 144 sq, mm size in existing panels , supply, replacement and fixing ammeter selector switch, 3 pole and off, 6a in existing panels , supply, replacement and fixing voltmeter selector switch, 3 pole and off, 6 a in existing panels , supply, replacement and fixing operating handle for mccb 100 amp to 400 amp in existing panels , supply, replacement and fixing fuse carrier with fuse link, 100 amp in existing panels , supply, replacement and fixing hrc fuse link 100 amp in existing panels etc complete as required , supply, replacement and fixing cfl lamp , pl l 4p lamp 36 w in existing fittings, , supplying, replacement and fixing 5 or 6 a switch, piano type, on the sb, cover, panel db etc , supplying, replacement and fixing 15 or 16 a switch, piano type, on the sb, cover, panel db etc , supplying, replacement and fixing 3 pin 5 or 6 a socket outlet, piano type, on the sb etc. as required , supplying, replacement and fixing sp mcb, 5 to 32 a, c series, on the sb, cover, panel db as reqd , repairs of ceiling fan 1200 or 1400 mm incl. dismantling, servicing, rewinding, reinstallation as reqd. , repairs of exhaust fan 450 mm incl. dismantling, servicing, rewinding, reinstallation as reqd. , supply, replacement and fixing 1400 mm ceiling fans complete as reqd. , repairing, rewinding of 2 hp sump pump set including greasing, varnishing, motor bush, etc as reqd. , supplying, fixing , replacement of faulty spares l rewinding of charging alternator for 380 kva ea , supplying, replacement and fixing of radiator fan v belt set compatible 380 kva ea set etc as reqd , supplying, replacement and fixing 12mm dia wire braided pvc diesel pipe compatible for 380 kva ea. , supplying, replacement and fixing ac ammeter 96 sq.mm, 0 to 200 a or 400 a for 380 kva ea as reqd. , supplying, replacement and fixing led indicator lamps, 230 v, r, y and g for 380 kva ea set. , carrying out repair incl.replacement of ecp control panel sefety control, for 125 kva ea as reqd. , carrying out repair incl. replacement, rectification of oil leakage from drain nut for 125kva ea , carrying out repair incl.replacement of stop solenoid valve with solenoid switch for 125 kva ea set , carrying out repair including replacement of spares and rewinding for 125kva ea set as reqd. , carrying out repairs of radiator incl. servicing, cleaning, and attending minor leakage in 125 ea. , carrying out repair including replacement for carry out b check servicing for existing 125 kva ea , carrying out repair inc.replacement led indicator lamps, 230 v, r, y and g for 125kva ea as reqd. , carrying out repair incl. replacement of dc voltmeter 72 sq.mm, 0 to 50 volt for 125kva ea as reqd. , carrying out repair incl.replacement of ac ammeter 96 sq.mm, 0 to 200 amp or 400 amp for 125kva ea. , carrying out repair incl.replacement ammeter and voltmeter selector switch for 125kva ea as reqd. , supplying, replacement and fixing of 12v, 7ah battery compatible for fd and fa system etc as reqd. , supplying, replacement and fixing smoke detector with built in led and mounting base. etc as reqd , supplying, replacement and fixing response indicator on surface or, ocm of ems telecom compound yerawada pune attending defects, supplying, replacement and fixing potential transformer of rating 11kv by 110v, 100va class1 in 11kv ht panel including installations, connections, testing and commissioning etc complete as reqd, supplying, replacement and fixing ammeter with range 0 to 20a, 144 mm x 144 mm size in existing panel including installations, connections, testing and commissioning etc complete as reqd, supplying, replacement and fixing voltmeter with range 0 to 15kv, 144 mm x 144 mm size in existing panel including installations, connections, testing and commissioning etc complete as reqd, supplying, replacement and fixing led type indicators lamp yellow, red, blue and green in colour including testing etc complete as reqd., supplying, replacement and fixing trivector meter including testing etc complete as reqd., heater rectification in 11kv ht panel of bieco lawrie including testing etc complete as reqd., supplying, replacement and fixing selector switch including testing etc complete as reqd., servicing of oil circuit breaker in 11kv ht panel of bieco lawrie including testing etc complete as reqd., service, maintenance and rectification of cable chattering, contact surface conditioning and associated works for transformer no. 2 busbar trunking links in ht panel, testing commissioning as reqd., supplying, replacement and fixing of marshalling box lock for 500 kva indoor transformer of kirloskar make complete as reqd., supplying, replacement and fixing of box cover gasket for 500 kva indoor transformer of m/s. kirloskar including testing etc complete as reqd., supplying, replacement and fixing of marshalling box glass for 500 kva indoor transformer of m/s. kirloskar including testing etc complete as reqd., supplying, replacement and toping of transformer oil for 500 kva indoor transformer of m/s. kirloskar including testing etc complete as reqd., supplying, replacement and fixing silica gel breather for 500 kva indoor transformer of m/s. kirloskar including testing etc complete as reqd., supplying, replacement and fixing of transformer conservator oil gauge for 500 kva indoor transformer of m/s. kirloskar including testing etc complete as reqd., supplying, replacement and fixing of transformer temparature gauge for 500 kva indoor transformer of m/s. kirloskar including testing etc complete as reqd., servicing and repairing of 800 to 250 amp. air circuit breakers incl.draw out from existing panel, cleaning of jaw contact and arcchut by using crc or wd40 proper alignment and testing etc as required, supply, replacement and fixing indicators lamp yellow, red and green colour in existing mv, lt, distribution panels including testing etc complete as required., supply, replacement and fixing indicators lamp blue colour in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing multifunction or intelligent meter in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing 10 kvar capacitor type md02 in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing ac voltmeter having range 0 to 600v class 1.0 accuracy, 144 sq. mm size in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing ac ammeter having range 0 to 600 amp class 1.0, 144 sq. mm size in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing ammeter selector switch, 3 pole and off, 6a in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing voltmeter selector switch, 3 pole and off, 6 a in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing operating handle for mccb 100 amp to 400 amp in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing fuse carrier with fuse link, 100 amp in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing hrc fuse link 100 amp in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing cfl lamp, pl l 4p lamp 36 w in existing fittings, fitting type 2 x 36 w cfl master pl l 36w l 865l4p 1ctl25) etc complete as required., supplying, replacement and fixing 5 or 6 amps switch, piano type, on the switch board, cover, panel db including connections etc. as required, supplying, replacement and fixing 15 or 16 amps switch, piano type, on the switch board, cover, panel db including connections etc. as required, supplying, replacement and fixing 3 pin 5 or 6 a socket outlet, piano type, on the switch board, cover, panel db including connections etc. as required, supplying, replacement and fixing sp mcb, 5 to 32 a, c series, on the switch board, cover, panel db including connections etc. as required, repairs of existing ceiling fan,1200 mm or 1400 mm incl. dismantling, servicing, rewinding, replacement of bearings, capacitor, to and fro transportation to repair, necessary reinstallation as reqd., repairs of existing exhaust 450 mm incl. dismantling, servicing, rewinding, replacement of bearings, capacitor, to and fro transportation to repair, necessary reinstallation as reqd., supply, replacement and fixing 1400 mm sweep ceiling fans complete as reqd., repairing, rewinding of 2 hp sump pump set including greasing, varnishing, replacement of motor bush, nut bolts and gland packing transportation loading, unloading testing comm. etc as required., supplying, fixing, replacement of faulty spares and rewinding of charging alternator of same make, model and compatible for existing 380 kva ea set, cummins make with itc etc complete as reqd., supplying, replacement and fixing of radiator fan v belt set of same make, model and compatible for existing 380 kva ea set, with installation, connection, testing, commissioning as required, supplying, replacement and fixing 12mm dia wire braided pvc diesel pipe of same make, model and compatible for existing 380 kva ea set, with installation, connection, testing, commissioning as reqd, supplying, replacement and fixing ac ammeter 96 sq.mm, 0 to 200a or 400a of same make, model and compatible for existing 380 kva ea set, with installation, connection, testing, commissioning as reqd, supplying, replacement and fixing led indicator lamps, 230 v, r, y and g of same make, model and compatible for existing 380 kva ea set, with installation, connection, testing, commissioning as reqd, carrying out repair incl. replacement of ecp control panel sefety control, rectification incl. mechanical operation for 125 kva ea set kirloskar make with testing, commissioning etc as reqd., carrying out repair including replacement , rectification of oil leakage from drain nut for existing 125 kva ea set kirloskar make with installation, testing, commissioning etc as reqd., carrying out repair including replacement of stop solenoid valve with solenoid switch for existing 125 kva ea set kirloskar make with installation, testing, commissioning etc as reqd., carrying out repair including replacement of spares and rewinding for existing 125kva ea set kirloskar make with installation, testing, commissioning as reqd., carrying out repairs of radiator including servicing, cleaning, and attending minor leakage for existing 125kva ea set with installation, testing, commissioning as reqd., carrying out repair including replacement, b check servicing for existing 125 kva ea set kirloskar make with testing etc complete as reqd., carrying out repair including replacement led indicator lamps, 230 v, r, y and g for existing 125 kva ea set kirloskar make with installation, testing, commissioning etc as reqd., carrying out repair including replacement dc voltmeter 72 sq.mm size, 0 to 50 volt for existing 125 kva ea set kirloskar make with installation, testing, commissioning etc as reqd., carrying out repair including replacement ac ammeter 96 sq.mm size, 0 to 200 amp or 400 amp for existing 125 kva ea set kirloskar make with installation, testing, commissioning etc as reqd., carrying out repair including replacement ammeter and voltmeter selector switch for existing 125 kva ea set kirloskar make with installation, testing, commissioning etc as reqd., supplying, replacement and fixing of 12v 7ah battery same make, model and compatible for existing fire detection and fire alarm system with connections, testing and commissioning complete as reqd., supplying, replacement and fixing of smoke detector with built in led and mounting base complete compatible for existing fd and fa system with testing & commissioning complete as reqd., supplying, replacement and fixing response indicator on surface or recess ms box having two leds metallic cover compatible for existing fd and fa system with testing, commissioning complete as reqd., supplying, replacement and fixing hammer, chain compatible for existing fd and fa system with testing, commissioning complete as reqd., supplying, replacement and fixing exit sign board compatible for existing fd and fa system with testing, commissioning complete as reqd., repairs of existing 7 tr conventional package ac twin ckt, singhson make incl. supplying, charging and topping of r22 refrigerent gas with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac, twin ckt, singhson make incl. replacement hp and lp cut out in the refrigerant circuit pu 1 and 2 with testing, commissioning complete as reqd., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement of hp gauge of pu 1 and 2 with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement of lp gauge with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement thermostat with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement condenser motor 1ph, 0.5hp for pu 1 with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement of filter drier of pu 2 with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement of overload relay of pu 1 and 2 with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement of pla relay of pu 1 with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement of on delay timer of pu 1 and pu 2 with testing, commissioning complete as required., repairs to the control wiring including replacement of circuit components, wiring, etc. if necessary for satisfactory operation of the package ac unit complete as required. for pu 1 and 2

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16345604
Location : sagar , madhya pradesh
Source : GEM Tenders
LIVE TENDER
tender for lv7-maruti 5365-011087 , lv7-maruti 54100m70a10 , lv7-maruti 5850-000337 , lv7-maruti 74416m83000 , lv7-mpvy f-1436211 , lv7-stln 2520-012650 , lv7-stln 2530-018237 , lv7-stln f-0244010 , lv7-stln p-3709639 , lv7-stln p3713139 , lv7-stln vf f-7139814 , lv7-stln vf p-1302805 , lv7-stln vf p-2403151 , lv7-stln vf p- 4304833 , lv7-stln vf x-5601500 , lv7-t-815 205-221- 119-4 , lv7-t-815 442-074-918-374 , lv7-t-815 442-076- 631-154 , lv7-t-815 442-960-550-184 , lv7-t-815 443-115- 032-0 , lv7-t-815 443-116-419-450 , lv7-t-815 443-312- 037-000 , lv7-t-815 443-654-091-000 , lv7-t-815 443-930- 131-640 , lv7-t-815 443-938-412-460 , lv7-t-815 4x4 442- 053-112-514 , lv7-t-815 4x4 443-612-131-000-a , lv7-t- 815 4x4 443-853-139-000 , lv7-t-815 hmv 442-073-900- 764 , lv7-t-815 hmv 442-077-400-694 , lv7-t-815 hmv 443-319-014-000 , lv7-tata 122281-yai-r00 , lv7-tata 2154-8240-9901 , lv7-tata l01402000035 , lv7-fat6x6- als b5a39803 , lv7-hmv-6x6-svi 503259200133 , lv7- hmv-6x6-tml 2863-5010-0122 , lv7-hmv-6x6-tml 500629300101 , lv7-hmv-8x8-al b0f08119 , lv7-hmv- 8x8-al f1000220 , lv7-hmv-8x8-al f9e10600 , lv7-hmv- 8x8-al x5k00100 , lv7-hmv-8x8-al x8832300 , lv7-hmv- 6x6-mbrl f8345700 , lv7-krz 100-3522010 , lv7-maruti 12340m82000 , lv7-maruti 12741m53b01 , lv7-maruti 12821m70c00 , lv7-maruti 12911m71c00 , lv7-maruti 12915m71c80 , lv7-maruti 13881-830a0 , lv7-maruti 14300-83412 , lv7-maruti 18117-830a0 , lv7-maruti 18133-84150 , lv7-maruti 24250-83020 , lv7-maruti 24560-83001 , lv7-maruti 2530-014013 mfr no- 48810m60a00 , lv7-maruti 31220m52a20 , lv7-maruti 31311m80110 , lv7-maruti 31320-82631 , lv7-maruti 31621m70f00 , lv7-maruti 37680-80002 , lv7-maruti 38410m66131 , lv7-maruti 38860m79f00, lv7-maruti 5365-011087 ring retaining, lv7-maruti 54100m70a10 lever assy parking brake, lv7-maruti 5850-000337 lamp assy side turn signal lh, lv7-maruti 74416m83000 holder control cable, lv7-mpvy f-1436211 driving flange, lv7-stln 2520-012650 drum clutch power - take off, lv7-stln 2530-018237 tir rod end steering, lv7-stln f-0244010 roller brg, lv7-stln p-3709639 brush gear assy, lv7-stln p3713139 armature, lv7-stln vf f-7139814 bracket - accelerator cable, lv7-stln vf p-1302805 sintered bush, lv7-stln vf p-2403151 seal kit valve sleeve, lv7-stln vf p-4304833 axle shaft lh, lv7-stln vf x-5601500 nbf injector for 135 kw bs-iii vp 37, lv7-t-815205-221-119-4 exhaust manifold screw, lv7-t-815442-074-918-374 fuel pipeline, lv7-t-815442-076-631-154 fuel supply tube, lv7-t-815442-960-550-184 air filter grid, lv7-t-815443-115-032-0 alternator, lv7-t-815443-116-419-450 voltage regulator, lv7-t-815443-312-037-000 rear cluster - 891 016, lv7-t-815443-654-091-000 hose tm02.16x300 dkl-dkl 27x1.5, lv7-t-815443-930-131-640 condenser, lv7-t-815443-938-412-460 resistor, lv7-t-815 4x4 442-053-112-514 hose, lv7-t-815 4x4 443-612-131-000-a reduction valve, lv7-t-815 4x4 443-853-139-000 relay aev 5201 24v, lv7-t-815 hmv 442-073-900-764 steering booster, lv7-t-815 hmv 442-077-400-694 set of seal rear axle 12 items, lv7-t-815 hmv 443-319-014-000 direction flasher switch over - ruhla, lv7-tata122281-yai-r00 gasket cyl head, lv7-tata2154-8240-9901 17w hi power wiper motor, lv7-tatal01402000035 armature assy, lv7-fat6x6-alsb5a39803 spring brake actuator 30-30, lv7-hmv-6x6-svi503259200133 hp hose, lv7-hmv-6x6-tml2863-5010-0122 assy radiator, lv7-hmv-6x6-tml500629300101 assy clutch booster type-1, lv7-hmv-8x8-alb0f08119 air drier, lv7-hmv-8x8-alf1000220 clutch master cyl assy, lv7-hmv-8x8-alf9e10600 head light assy, lv7-hmv-8x8-alx5k00100 quick release valve repair kit, lv7-hmv-8x8-alx8832300 system protection valve, lv7-hmv-6x6-mbrlf8345700 solenoid agb high low, lv7-krz100-3522010 trailer brake control valve assy, lv7-maruti12340m82000 bearing set crank shaft, lv7-maruti12741m53b01 pulley cam shaft timing, lv7-maruti12821m70c00 spring tensioner, lv7-maruti12911m71c00 valve intake, lv7-maruti12915m71c80 valve exhaust 4 valve mpfi, lv7-maruti13881-830a0 hose outlet, lv7-maruti14300-83412 muffler, lv7-maruti18117-830a0 valve assy solenoid, lv7-maruti18133-84150 filter, lv7-maruti24250-83020 gear t-m main shaft 5th, lv7-maruti24560-83001 gear reverse idle nt, lv7-maruti2530-014013 mfr no-48810m60a00 end steering tie rod, lv7-maruti31220m52a20 switch assy, lv7-maruti31311m80110 armature assy, lv7-maruti31320-82631 clutch assy, lv7-maruti31621m70f00 holder assy rectifier, lv7-maruti37680-80002 switch 4 wheel drive, lv7-maruti38410m66131 pump assy, lv7-maruti38860m79f00 relay main and fuel

Unlock Full Tender Access

Start Free Trial to download documents before deadline

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15229023
Location : rupsi , assam
Source : GEM Tenders
corrigendum tender for operation and maintenance of electrical and mechanical installations , job contract for operation and day to day maintenance services of airport systems equipments , execution of item of schedule of rates cpwd dsr 2022 as and when required , testing of transformer oil sample including conducting bdv test and submission of test report etc complete as required , filtration of transformer oil of 630 kva transformer , servicing and checking of lt air circuit breaker , servicing and checking of ht vacuum circuit breaker , calibration and testing of relays at ht panel , calibration and testing of following relays at lt and synchronizing panel , scrubbing, cleaning the existing surface of cubicle panel, feeder pillars and painting , lettering of maximum 2 inch size alphabetic or numerical , cleaning the surface of ms chequered plates , supply and replacement of silica gel in breather of existing 630 kva transformer etc. complete as required , lifting and lowering of 10 hp borewell submersible motor pump set , servicing and complete overhauling of 10 hp borewell submersible motor pump set , decoration of terminal building and canopy of rupsi airport , supply and replacement of defective smoke detectors , supply and replacement of defective manual call point , supply of convertor or driver suitable for philips make 20 w downlight types led luminaires or fittings , supply of convertor or driver suitable for osram make 120w types led luminaires or fittings , supply of convertor or driver suitable for havells make 18 or 20 w downlight types led luminaires or fittings , supply of convertor or driver suitable for wipro make 36w 2ftx2ft recess mounted fitting , supply of 1000w 240v lamp suitable for aerodrome beacon , supply of aerodrome beacon , calibration of clinometer , supply of reflector suitable for ama make papi , supply of 2c x 4 sq mm. secondary lead with plug , supply of b connector or four way porcelain terminal , supply of 5 kv grade 50 hz ac isolating transformer , supply of two pin halogen lamp holder suitable for 200 watt , supply of 5 w screw cap led lamp , supply of wind sock cloth , supply and replacement of led flood light , supply and replacement of obstruction light of wind direction indicator , supply and replacement of 180 ah 12 v lead acid battery , supply and replacement of 100 ah 12 v lead acid battery , supply of automaic electric hand drier , servicing, checking repairing overhauling and testing of crompton make 630 kva transformer, annual operation and maintenance of electrical and mechanical works at rupsi airport, operation and maintenance of electrical and mechanical installations of operational and non operational areas including terminal buildling, ats building, fire station, electrical substation and other ancillary buildings for round the clock operation on all days including sundays and holidays by engaging following manpower along with providing required tool and consumables as specified in special conditions of contract for day to day maintenance except spares. the job includes preventive, routine maintenance, attending complaint or fault or breakdown by taking rectification action ensuring serviceability and satisfactory working condition of the system, maintaining all records and documentation etc. complete as per agreement conditions and as per the instruction of eic. 1. supervisor (highly skilled) - 01 no. 2. document assistant (highly skilled) - 01 no. 3. wireman (skilled) - 07 nos. 4. semi-skilled- 06 nos. 5. helper (unskilled) - 03 nos. (the above manpower is excluding reliever), job contract for operation and day to day maintenance services of airport systems equipments including scctv camera system, fids , pa system, hhmd, dfmd, security equipments, bdds equipments, xbis machines, etd equipment etc. installed at terminal building, ancillary building at rupsi airport. job also includes attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, providing registers and log books as per formats given in tender document and maintenance of daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, registers and log books and coordination with oem technicians during cmc works etc. by deploying following manpowers as per scope of work given in special conditions of contract shall be ensured round the clock (ie. in one shifts basis) on all days including sundays & national holidays as per direction of eic and as per attached annexure-a of atc. 1. supervisor (high skilled) -01 no. 2. technician ( skilled) -01 no. (the above manpower is excluding reliever), execution of item of schedule of rates cpwd dsr 2022 as and when required for attending breakdown, repair and maintenance and upkeep of internal & external electrical installations as per direction of e-i-c at different locations of operational and non operational area i/c terminal building, ats building, fire station, electrical substation and other ancillary buildings etc. the bidder shall quote the rate in inr only including price escalation for 01 year for the job corresponding to an amount of rs. 1,00,000.00 (including gst from dsr 2022 items) and percentage (%) above/below shall be calculated by aai and paid accordingly., testing of transformer oil sample including conducting bdv test and submission of test report etc. complete as required, filtration of transformer oil of 630 kva transformer to attain acceptable di-electric strength by hot streamline process including arrangement of plant/machine, transportation etc. complete as required by topping of transformer oil and bdv testing including submission of test reports before & after dehydration of oil. (excluding cost of transformer oil) (item is to be executed if the bdv value of transformer oil is found below the stipulated value)., servicing & checking of lt air circuit breaker (acb) of l&t u power omega make by deploying authorised service personnel of manufacturer/ oems service dealers as per oems standards complete as required and submission of service reports., servicing & checking of ht vacuum circuit breaker (vcb) of siemens make by deploying authorised service personnel of manufacturer/oems service dealers as per oems standards complete as required and submission of service reports., calibration and testing of following relays at ht panel by deploying authorised service personnel of manufacturer/oems service dealers as per oems standards complete as required and submission of service reports. i) vamp 57 - 5 nos. (numerical type of schneider make) ii) vajh13 - 5 nos. (tripping relay of alstom make) iii) vax31 - 5 nos. (trip circuit supervision relay of alstom make) iv) vaa33 - 4 nos. (auxiliary relay of alstom make), calibration and testing of following relays at lt & synchronizing panel by deploying authorised service personnel of manufacturer/oems service dealers as per oems standards complete as required and submission of service reports. i) vajh13 - 2 nos. (tripping relay of alstom make) ii) vax31 - 2 nos. (trip circuit supervision relay of alstom make) iii) ccum21pf112a - 2 nos. (definite time reverse power relay of areva make) iv) cag14af15a - 2 nos. (instantaneous earth fault relayof alstom make), scrubbing, cleaning the existing surface of cubicle panel, feeder pillars & painting the same with one coat of primer and one coat of synthetic enamel paint of approved colour etc. complete as required, lettering of maximum 2inc size (alphabetic / numerical) on the finished painted surface of feeder pillar / panel / earth pits with synthetic enamel paint of approved colour etc. complete as required., cleaning the surface of ms chequered plates and painting with one coat of primer and two coats of synthetic enamel black paint etc. complete as required., supply and replacement of silica gel in breather of existing 630 kva transformer etc. complete as required, lifting and lowering of 10 hp borewell submersible motor pump set along with dismantling of complete delivery pipeline, removal of pump sets, disconnection of flexible submersible cable, reassembling of submersible pump, complete delivery pipeline, fixing / laying of existing submersible cable including electrical connection, testing and commissioning etc. complete as required., servicing and complete overhauling of 10 hp borewell submersible motor pump set including replacement of defective bearing, coupling, impellar, mechanical & oil seal, heat varnishing of motor etc. complete as required, decoration of terminal building and canopy of rupsi airport, in tri-colour, with the following lighting items of pattern approved by e-i-c or his authorized representative, for 03 days etc. complete as required. i) 60 nos. led series lighting chain (minimum chain length 5m and uniform spacing between chains not more than 0.75 m) ii) 20 nos. rgb led facade/ disco/ flood light fittings (minimum 10000 lumen output), supply and replacement of defective smoke detectors of suitable make & model compatible to the existing system., supply and replacement of defective manual call point of suitable make & model compatible to the existing system, i) philips make 20 w downlight type dn195b led20s, ii) osram make 120w type. ledenvo led street light, iii) havells make 18/20 w downlight, iv) wipro make 36w 2ftx2ft recess mounted fitting, supply of 1000w , 240v lamp suitable for aerodrome beacon of model ab-1000f make- manairco inc as and when required., supply of aerodrome beacon of model ab-1000f make- manairco inc as and when required., calibration of clinometer from govt. test laboratory/ oem, submission of test report etc., complete as required i/c taking the equipment from aais site to laboratory and bringing back the same from laboratory to aais site., supply of reflector suitable for ama make papi fittings as and when required., supply of 2c x 4 sq mm. secondary lead with plug at one end of standard length of 5 m as and when required, supply of b - connector / four-way porcelain terminal for ama make papi units as and when required, supply of following rating 5 kv grade, 50 hz ac isolating transformer, series type, encapsuled in polyster resin, finally moulded in neoprene type rubber with primary and secondary leads, confirming to latest specifications as required suitable for airfield lighting applications etc. as and when required. 200 watt, 6.6/6.6 amp., supply of two pin halogen lamp holder suitable for 200 watt, 6.6 amp lamp as and when required., supply of 5 w screw cap led lamp suitable for landing t , efficacy not less than 100 lm/w as and when required., supply of wind sock cloth, 13 ft 9 inch length, colour preferably orange & white and conforming to icao annex-14 as and when required., supply and replacement of led flood light for mounting on wind direction indicator, equivalent to philips make model bvp132led16/cw 20w 100-240v wb in as and when required., supply and replacement of obstruction light of wind direction indicator as and when required., supply and replacement of 180 ah 12 v lead-acid battery, conforming to is 14257 1995 with up to date amendments, suitable for high cranking performance of 400 kva dg set as and when required., supply and replacement of 100 ah 12 v lead-acid battery, conforming to is 14257 1995 with up to date amendments, suitable for high cranking performance of 62.5 kva dg set as and when required, supply of automaic electric hand drier of following specifications or equivalent make omco, model ipx1,voltage-220-240v, power 1800w, servicing, checking, repairing, overhauling and testing of crompton make 630 kva, 11/0.433 kv transformer including carrying out the following tests by deploying authorised service personnel of manufacturer/oems service dealers as per oems standards complete as required and submission of reports. a) general inspection b) ir value test primary to secondary, primary to earth, secondary to earth c) votage ratio check at all tap position, d) buchholz relay operation e) oti operation f) wti operation g) on-load tap changer operation check h) cleaning of transformer and replacement of silica gel i) acidity check test of transformer oil.

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Air Drier Repair. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Air Drier Repair sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Air Drier Repair Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Air Drier Repair, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Air Drier Repair Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Air Drier Repair Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Air Drier Repair.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Air Drier Repair depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Air Drier Repair Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Air Drier Repair bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Air Drier Repair. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Air Drier Repair, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Air Drier Repair, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Air Drier Repair?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Air Drier Repair tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Air Drier Repair?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Air Drier Repair, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Air Drier Repair is declared L1 and is generally awarded the contract