Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Air cooled condensers Tenders List

Latest Air cooled condensers Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Air cooled condensers tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Air cooled condensers tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Air cooled condensers Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Air cooled condensers tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Air cooled condensers Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Air cooled condensers Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Air cooled condensers Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Air cooled condensers tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Air cooled condensers Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Air cooled condensers sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Air cooled condensers tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Air cooled condensers tenders.

Is EMD mandatory for all Air cooled condensers tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Air cooled condensers work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Air cooled condensers tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Air cooled condensers Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 14994783
Location : chandigarh , chandigarh
Source : GEM Tenders

tender for supplying of 1.5 tr nominal capacity invertor type metal body , installation, testing and commissioning of of 1.5 tr inverter type ductable air cooled split ac unit as per item no.1 above in equipment room , providing and fixing heavt duty powder coated m s stand of suitable size made out of suitable guage ms shee , supply and fixing of 3 core 2.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply and fixing of 4 core 1.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply installation testing and commissioning including vaccumiazation and nitrogen testing of , supply installation testing and commissioning including vaccumiazation and nitrogen , supplying and fixing of 25 mm sizes of rigid upvc piping from outlet socket of ac unit complete with elbow , supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 230 v c curve dp mcb , supplying and fixing 5 amps to 32 amps rating, 240 or 415 volts c curve miniature circuit breaker suitable for inductive load of single pole and neutral , providing and fixing supply air grills of powder coated aluminum construction having a free area of not less than 70 percent without volume control dampers , supplying and installing of 150 mm width 50 mm depth 1.6 mm thickness nominal size of perforated hot dipped galvanised iron cable tray, supplying of 1.5 tr nominal capacity invertor type metal body ceiling or wall suspended single circuit high static pressure ductable split ac unit with eer not less than 9.5 btu/w-h (not less than 2.8 w/w) having cooling capacity not less than 18000 btu/hr, minimum 45 pa static pressure suitable for operation on 230 v single phase 50 hz ac supply having front flow type indoor unit, air cooled condenser, initial charge of eco friendly refrigerent gas as per atc, installation, testing and commissioning of of 1.5 tr inverter type ductable air cooled split ac unit as per item no.1 above in equipment room as per atc, providing and fixing heavt duty powder coated m s stand of suitable size made out of suitable guage ms shee as per atc, supply and fixing of 3 core 2.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor as per atc, supply and fixing of 4 core 1.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor as per atc, supply installation testing and commissioning including vaccumiazation and nitrogen as per atc, supply installation testing and commissioning including vaccumiazation and nitrogen as per atc, supplying and fixing of 25 mm sizes of rigid upvc piping from outlet socket of ac unit complete with elbow as per atc, supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 230 v c curve dp mcb as per atc, supplying and fixing 5 amps to 32 amps rating, 240 or 415 volts c curve miniature circuit breaker suitable for inductive load of single pole and neutral as per atc, providing and fixing supply air grills of powder coated aluminum construction having a free area of not less than 70 percent without volume control dampers as per atc, supplying and installing of 150 mm width 50 mm depth 1.6 mm thickness nominal size of perforated hot dipped galvanised iron cable tray as per atc


Tender Value : 9444430
Due Date : May 02, 2026
T18 Ref No : 15074347
Location : lucknow , uttar pradesh
Source : GEM Tenders

tender for supply of ductable ac , itc of ductable ac , refrigerant piping , ms frame , 3x2.5 sq.mm pvc copper conductor , m s cable tray , pvc flaxible pipe , aluminium supply air grills , gss sheet 24 gauge , fire retardent canvass, supply installation testing and commissioning of ductable ac, supply of ceiling/wall suspended 1.5 tr nominal capacity metal body inverter type ductable air cooled split ac unit having cooling capacity 18000 btu/hr, with external static pressure minimum 30 pa where no duct/small duct is required and minimum 45 pa where long duct is required and minimum energy efficient ratio eer 9.5 btu/w h, suitable for r 410a/32 or similar environment friendly refrigerant gas with rotary/scroll compressor, wireless remote, air cooled condenser complete with all standard fittings etc including transportation, first charging of refrigerant gas, leak testing etc complete as per specifications and terms and conditions attached. the indoor and outdoor units shall have copper tubes/pipes only. make carrier/ daiken/ hitachi/ o general/ blue star/ voltas/ mitsubishi electric india/ mitsubishi heavy industries/ panasonic/ lg/ samsung, installation, testing and commissioning of above 1.5 tr metal body inverter type ductable air conditioning unit including fixing the outdoor unit on the existing platform / stand with necessary vibration arrestors, fixing the indoor unit on the ceiling /wall, making opening in the wall if required and making good the damages, providing interconnection between indoor and outdoor units, gas charging, electrical connection from power outlet near condenser unit to condensor etc complete with suitable supporting, fitting of ducting, stand, lead, damper/grill, canvas with suitable insulation and conduit complete in all respect., supplying and laying of suitable size copper refrigerant piping both liquid and suction lines in the existing tray for the above 1.5 tr inverter type ductable split ac unit along with necessary accessories like nitrile rubber insulation, clamping, brasing etc as required., fabrication and fixing of ms frame made of required size ms angle, ms flats etc for supports for indoor units, out door unit ladder type trays etc i/c cutting, drilling holes, welding grouting, painting, fixing on wall, roof etc as required . as directed by engineer in charge, supplying and laying of 3x2.5 sq.mm pvc insulated flexible copper conductor cable along the surface of wall / in the existing tray etc as required., supplying and installing following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5percentage, in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts and nuts, painting suspenders etc. as required. a. 200 mm width x 50 mm depth x 1.6 mm thickness, s/f of 20 mm braided pvc flexible pipe for condensate drain from indoor unit to the nearest drain point provided as required., supplying and fixing of powder coated extruded aluminium supply air grills with aluminium volume control dampers as per specifications, supply and fabrication of gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. sail/ tata/ jindai / bsnl approved make. a. 24 guage, supply and fixing of suitable size fire retardent canvass connection complete as per site requirement.


Tender Value : 2284468
Due Date : May 09, 2026
T18 Ref No : 15197977
Location : chandigarh , chandigarh
Source : GEM Tenders

corrigendum tender for supplying of 1.5 tr nominal capacity invertor type metal body , installation, testing and commissioning of of 1.5 tr inverter type ductable air cooled split ac unit as per item no.1 above in equipment room , providing and fixing heavt duty powder coated m s stand of suitable size made out of suitable guage ms shee , supply and fixing of 3 core 2.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply and fixing of 4 core 1.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor , supply installation testing and commissioning including vaccumiazation and nitrogen testing of , supply installation testing and commissioning including vaccumiazation and nitrogen , supplying and fixing of 25 mm sizes of rigid upvc piping from outlet socket of ac unit complete with elbow , supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 230 v c curve dp mcb , supplying and fixing 5 amps to 32 amps rating, 240 or 415 volts c curve miniature circuit breaker suitable for inductive load of single pole and neutral , providing and fixing supply air grills of powder coated aluminum construction having a free area of not less than 70 percent without volume control dampers , supplying and installing of 150 mm width 50 mm depth 1.6 mm thickness nominal size of perforated hot dipped galvanised iron cable tray, supplying of 1.5 tr nominal capacity invertor type metal body ceiling or wall suspended single circuit high static pressure ductable split ac unit with eer not less than 9.5 btu/w-h (not less than 2.8 w/w) having cooling capacity not less than 18000 btu/hr, minimum 45 pa static pressure suitable for operation on 230 v single phase 50 hz ac supply having front flow type indoor unit, air cooled condenser, initial charge of eco friendly refrigerent gas as per atc, installation, testing and commissioning of of 1.5 tr inverter type ductable air cooled split ac unit as per item no.1 above in equipment room as per atc, providing and fixing heavt duty powder coated m s stand of suitable size made out of suitable guage ms shee as per atc, supply and fixing of 3 core 2.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor as per atc, supply and fixing of 4 core 1.5 sq mm control cum transmission wiring and ac power supply cable of shielded copper conductor for looping between indoor and outdoor as per atc, supply installation testing and commissioning including vaccumiazation and nitrogen as per atc, supply installation testing and commissioning including vaccumiazation and nitrogen as per atc, supplying and fixing of 25 mm sizes of rigid upvc piping from outlet socket of ac unit complete with elbow as per atc, supplying and fixing dp sheet steel enclosure on surface or recess along with 25 or 32 a 230 v c curve dp mcb as per atc, supplying and fixing 5 amps to 32 amps rating, 240 or 415 volts c curve miniature circuit breaker suitable for inductive load of single pole and neutral as per atc, providing and fixing supply air grills of powder coated aluminum construction having a free area of not less than 70 percent without volume control dampers as per atc, supplying and installing of 150 mm width 50 mm depth 1.6 mm thickness nominal size of perforated hot dipped galvanised iron cable tray as per atc


Tender Value : 9444430
Due Date : May 06, 2026
T18 Ref No : 14972483
Location : huzur , madhya pradesh
Source : GEM Tenders

corrigendum tender for supply of 1.5 tr invertor ductable ac , itc of 1.5 tr ductable ac , supply fixing copper piping for 1.5 tr , supply fixing ms stand , sf upvc drain pipe 25 mm dia , sf upvc drain pipe 40 mm dia , supply laying of 3x1.5 sqmm cable , supply laying of 3x2.5 sqmm cable , sf dp sheet steel enclosure with dp mcb , sf 5 amps to 32 amps 240 volts spmcb , gi ducting of thickness 0.63 mm sheet , gi ducting of thickness 0.80 mm sheet , providing fixing aluminium grill , providing fixing canvass connection, supply installation testing and commissioning of ductable ac at gwalior, supplying of 1.5 tr nominal capacity metal body ceiling wall suspended single circuit, high static pressure ductable split ac unit with eer not less than 9.5 btu wh having cooling capacity not less than 18000 btu/hr, minimum 45 pa static pressure suitable for operation on 230 v single phase 50 hz ac supply having front flow type indoor unit, air cooled condenser, initial charge of eco friendly refrigerent gas (r32/r410a) rotary/scroll compressor lcd remote control, protection from under voltage, over voltage, phase imbalance voltage, phase loss, phase reverse & hp/lp etc as per manufacturer/ departmental specifications etc as required. the evaporator and condenser coil comprise of copper tube aluminum fin, installation, testing and commissioning of of following capacity inverter type ductable air cooled split ac unit as per item no.1 and 2 above in equipment room, cooling unit comprising of front flow type indoor unit, air cooled condenser including providing suspension /support of indoor unit from ceiling / wall as per site conditions and installation of outdoor unit on existing ms structure with necessary vibration arrestors and providing interconnection between indoor and outdoor units, electrical connection from power outlet making opening in the wall if required and minor civil work & making good the damages leak testing etc complete as per manufacturer recommendation / departmental specifications etc complete as required.\n(a) 1.5tr ductable, supplying and fixing copper refrigerent pipe line (hot gas and liquid) suitable for 1.5 tr ductable split ac units both 1/4 inch for gas line and 1/2 inch, (outer dia & 1.2 mm thick) for interconnection of outdoor and indoor units as per manufacturer specification on existing ms tray / surface alongwith suitable size rubber foam/insulation i/c necessary flare nuts, suitably brazing with the existing pipe clamping, making holes in walls same etc., as per site requirement., supplying of factory fabricated powder coated heavy duty wall/floor mounted ms stand (bracket) compatible with outdoor unit of ductable split air conditioner units upto 3.0 tr capacity for installation of condenser (out door) unit, fixing the same on wall with suitable size fastners/ nuts bolts and making good the demages etc as per site requirement., supplying and fixing of following sizes of rigid u-pvc piping from outlet socket of ac unit complete with elbow, t-joint, socket duly supported as per site requirement and insulated with 6 mm thick closed cell nitrile rubber insulation etc. complete as reqd for drainage purpose. strain clamps, bolts, nuts, washers including cutting and making good the walls etc. complete as required.\n(a) 25 mm dia, 2 mm thick., supplying and fixing of following sizes of rigid u-pvc piping from outlet socket of ac unit complete with elbow, t-joint, socket duly supported as per site requirement and insulated with 6 mm thick closed cell nitrile rubber insulation etc. complete as reqd for drainage purpose. strain clamps, bolts, nuts, washers including cutting and making good the walls etc. complete as required.\n(b) 40 mm dia, 2 mm thick., supply and laying of following size pvc insulated shielded multi strand frls copper flexible cable including interconnection etc. complete as required\n(a) 3 x 1.5 sq mm, supply and laying of following size pvc insulated shielded multi strand frls copper flexible cable including interconnection etc. complete as required\n(b) 3 x 2.5 sq.mm, supplying and fixing dp sheet steel enclosure on surface recess along with 25 or 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required., supplying and fixing 5 amps to 32 amps 240 volts single pole , c curve, miniature circuit breaker suitable for inductive load in the existing mcb db complete with connections, testing and commissioning etc. as required., supplying, installing, balancing and commissioning of fabricated at site gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets elbows, splitter dampers, vanes hangers support as per approved drawing and specifications of following sheet thickness complete as required\nthickness 0.63 mm sheet, supplying, installing, balancing and commissioning of fabricated at site gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets elbows, splitter dampers vanes hangers support as per approved drawing and specifications of following sheet thickness complete as required.\nthickness 0.80 mm sheet, providing & fixing supply air grills of powder coated aluminum construction having a free area of not less than 70% without volume control dampers in the supply air system as per site requirements complete as per detailed specifications, providing canvass connection made from suitable cloth and suitable required flanges made from gi material on both end for connecting ductable ac units with duct etc. as reqd.


Tender Value : 4044314
Due Date : Apr 13, 2026
T18 Ref No : 14972477
Location : huzur , madhya pradesh
Source : GEM Tenders

corrigendum tender for supply of 1.5 tr invertor ductable ac , itc of 1.5 tr ductable ac , supply fixing copper piping for 1.5 tr , supply fixing ms stand , sf upvc drain pipe 25 mm dia , sf upvc drain pipe 40 mm dia , supply laying of 3x1.5 sqmm cable , supply laying of 3x2.5 sqmm cable , sf dp sheet steel enclosure with dp mcb , sf 5 amps to 32 amps 240 volts spmcb , gi ducting of thickness 0.63 mm sheet , gi ducting of thickness 0.80 mm sheet , providing fixing aluminium grill , providing fixing canvass connection, supply installation testing and commissioning of ductable ac at bsnl hoshangabad, supplying of one point five tr nominal capacity metal body ceiling wall suspended single circuit high static pressure ductable split ac unit with eer not less than nine point five btu wh having cooling capacity not less than 18000 btu/hr minimum 45 pa static pressure suitable for operation on 230 v single phase 50 hz ac supply having front flow type indoor unit air cooled condenser initial charge of eco friendly refrigerent gas (r32/r410a) rotary/scroll compressor lcd remote control protection from under voltage over voltage phase imbalance voltage phase loss phase reverse & hp/lp etc as per manufacturer/ departmental specifications etc as required the evaporator and condenser coil comprise of copper tube aluminum fin, installation testing and commissioning of of following capacity inverter type ductable air cooled split ac unit as per item no 1 above in equipment room cooling unit comprising of front flow type indoor unit air cooled condenser including providing suspension /support of indoor unit from ceiling / wall as per site conditions and installation of outdoor unit on existing ms structure with necessary vibration arrestors and providing interconnection between indoor and outdoor units electrical connection from power outlet making opening in the wall if required and minor civil work & making good the damages leak testing etc complete as per manufacturer recommendation / departmental specifications etc complete as required\n(a) one and half tr ductable, supplying and fixing copper refrigerent pipe line (hot gas and liquid) suitable for one and half tr ductable split ac units both 1/4 inch for gas line and 1/2 inch (outer dia & 12 mm thick) for interconnection of outdoor and indoor units as per manufacturer specification on existing ms tray / surface alongwith suitable size rubber foam/insulation i/c necessary flare nuts suitably brazing with the existing pipe clamping making holes in walls same etc as per site requirement, supplying of factory fabricated powder coated heavy duty wall/floor mounted ms stand (bracket) compatible with outdoor unit of ductable split air conditioner units upto 3 tr capacity for installation of condenser (out door) unit fixing the same on wall with suitable size fastners/ nuts bolts and making good the demages etc as per site requirement, supplying and fixing of following sizes of rigid u-pvc piping from outlet socket of ac unit complete with elbow t-joint socket duly supported as per site requirement and insulated with 6 mm thick closed cell nitrile rubber insulation etc complete as reqd for drainage purpose strain clamps bolts nuts washers including cutting and making good the walls etc complete as required\n(a) 25 mm dia 2 mm thick, supplying and fixing of following sizes of rigid u-pvc piping from outlet socket of ac unit complete with elbow t-joint socket duly supported as per site requirement and insulated with 6 mm thick closed cell nitrile rubber insulation etc complete as reqd for drainage purpose strain clamps bolts nuts washers including cutting and making good the walls etc complete as required\n(b) 40 mm dia 2 mm thick, supply and laying of following size pvc insulated shielded multi strand frls copper flexible cable including interconnection etc complete as required\n(a) 3 x 1.5 sq mm, supply and laying of following size pvc insulated shielded multi strand frls copper flexible cable including interconnection etc complete as required\n(b) 3 x 2.5 sqmm, supplying and fixing dp sheet steel enclosure on surface recess along with 25 or 32 a 240 v c curve dp mcb complete with connections testing and commissioning etc as required, supplying and fixing 5 amps to 32 amps 240 volts single pole c curve miniature circuit breaker suitable for inductive load in the existing mcb db complete with connections testing and commissioning etc as required, supplying installing balancing and commissioning of fabricated at site gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets elbows splitter dampers vanes hangers support as per approved drawing and specifications of following sheet thickness complete as required\nthickness 0.63 mm sheet, supplying installing balancing and commissioning of fabricated at site gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets elbows splitter dampers vanes hangers support as per approved drawing and specifications of following sheet thickness complete as required\nthickness 0.80 mm sheet, providing & fixing supply air grills of powder coated aluminum construction having a free area of not less than 70% without volume control dampers in the supply air system as per site requirements complete as per detailed specifications, providing canvass connection made from suitable cloth and suitable required flanges made from gi material on both end for connecting ductable ac units with duct etc as reqd


Tender Value : 4044314
Due Date : Apr 13, 2026
T18 Ref No : 15247132
Location : new delhi , delhi
Source : GEM Tenders

tender for operation of microprocessor based hvac system , all inclusive comprehensive maintenance , replacement of damaged and worn out control and power wiring , dismantling and replacement of existing faulty 2 amp dp mcb , dismantling and replacement of existing faulty mpcb ms 116 , replacement of burnt broken and rusted terminal block , dismantling and replacement of following sizes of existing worn out faulty pipe 200mm dia 32 mm thick insulation , 150mm dia 32 mm thick insulation , 125mm dia 32 mm thick insulation , 100mm dia 32 mm thick insulation , 80mm dia 32 mm thick insulation , 65mm dia 32 mm thick insulation , dismantling and replacement of following sizes of existing worn out ndustrial type pressure gauges , providing and fixing in position the mercury in glass industrial type thermometers , butterfly valve manual with c i body ss disc a 150 mm dia , 100 mm dia , dismantling and replacement of following existing worn out faulty tpmccb 100 a 16 ka tpmccb , 200 a 25 ka tpmccb , 630 a 50 ka tpmccb , 800 a 50 ka tpmccb , making suitable modification replacement of overheated existing aluminium bus bar , dismantling and replacement of existing worn out faulty paddle type water flow , attending leakage in the existing chilled water pipeline , replacement of the following items of existing electrical panels mnx 32 contactor make l andtac plant room , mnx 25 contactor make l andt , 2noplus2 nc add on blockmake l andt , overload relay mn 2 of range 9 to 15 amps make l andt , single phase preventer , on off push button with elements , led indication lampr y b g , 3 way selector switch , star delta timer , digital voltmetermake select or ss , digital ammeter make select or ss , v belt , painting of existing old electrical panel, om hvac bsb janpath nd, operation of microprocessor based hvac system of capacity 5 x 100 tr chilling machines with screw compressors and air cooled condensers as detailed in annexure a and ductable tower type split ac and split ac as detailed in annexure b by deputing the following staff \n skilled semi skilled unskilled \n6 am to 2pm 1 1 2\n2 pm to 10 pm 1 1 2\ngeneral shift 9 am to 5 pm 1 0 0\nnotes \n1 staff may be asked to work in any shift and any day without any extra cost \n2 bill processed receipt proof online salary transfer account epf esi contr presently 12 perct and 3 25 perct ofpay respas reqt \n3 if esi and epf contributions rescission work initiated \n4 staff deployed enrolled attendance system\n5 the contractor ensure personnel meet defined standards f\n6 operation of the pumps 7 operation of ahus and tfa \n8 oper electrical panels\n9 recording readings chillers ahus pumps digital temperature meter \n10 to attend the floor complaints \n11 weekly washing ahus filters and ahus room\n12 chemical cleaning ahus cooling coil\n13 general checking testing and attending minor faults 14 out of skill manpower one skill operator electrician\n15 to carry out leak test compressors condenser coil with soap items are as per schedule of work item 1, all inclusive comprehensive maintenance of following items as per inventory at per annexure b given in relevant sections up to the required standards etc as per specification the items are \n1 ductable ac units\n2 tower split ac units\n3 split ac units \n items are as per schedule of work item 2, replacement of damaged and worn out control and power wiring of star delta starter panel for one motor in existing ahus electrical panel with new pvc insulated copper conductor wires of suitable size including providing and fixing of thimbles ferrules and new insulated fiber sheet for proper insulation removing of existing contactors cleaning and re fixing the same in position after proper checking and tightening of all connections complete as required items are as per schedule of work item 3, dismantling and replacement of existing faulty 2 amp dp mcbs in existing star delta starter panels of chilled water pumps on both primary and secondary sides i c testing etc complete as required items are as per schedule of work item 4, dismantling and replacement of existing faulty mpcb ms 116 in existing star delta starter panels of chilled water pumps on both primary and secondary sides i c testing etc complete as required items are as per schedule of work item 5, replacement of burnt broken and rusted terminal block 63 amp rating along with 2 nos lugs in the existing electrical panel of ahu s chilled water pump s etc complete as required items are as per schedule of work item 6, dismantling and replacement of following sizes of existing worn out faulty pipe at different floors levels i c supplying laying fixing testing and commissioning of nominal sizes of chilled water piping inside the building with necessary clamps vibration isolators and fittings but excluding valves strainers gauges etc duly insulated with following closed cell elastometric nitrile rubber of minimum 45 kg cu m density thermal conductivity 0 037 w mk or better at 20 deg mean temperature class o insulation applied by suitable adhesive complete including repairing of damage to building etc as per specifications and as required complete in all respect \nnote the pipes of sizes 150mm and below shall be m s c class as per is 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is 3589 from minimum 6 35mm thick m s sheet for pipes upto 350 mm dia and from minimum 7mm thick ms sheet for pipes of 400 mm dia and above \na 200mm dia 32 mm thick insulation items are as per schedule of work item 7 a, 150mm dia 32 mm thick insulation items are as per schedule of work item 7 b, 125mm dia 32 mm thick insulation items are as per schedule of work item 7 c, 100mm dia 32 mm thick insulation items are as per schedule of work item 7 d, 80mm dia 32 mm thick insulation items are as per schedule of work item 7 e, 65mm dia 32 mm thick insulation items are as per schedule of work item 7 f, dismantling and replacement of following sizes of existing worn out faulty components at different floors levels i c supplying fixing testing and commissioning of valves gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications 8 1 providing and fixing in position the industrial type pressure gauges with gun metal brass valves complete as required items are as per schedule of work item 8 1, providing and fixing in position the mercury in glass industrial type thermometers items are as per schedule of work item 8 2, butterfly valve manual with c i body ss disc nitrile rubber seal and o ring pn 16 pressure rating for chilled water hot eater circulation as specified a 150 mm dia items are as per schedule of work item 8 3 a, 100 mm dia items are as per schedule of work item 8 3 b, dismantling and replacement of following existing worn out faulty tpmccb at different floors levels i c fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel making connections ics100 perc icu and operational voltage 690v etc as required 100 a 16 ka tpmccb items are as per schedule of work item 9 a, 200 a 25 ka tpmccb items are as per schedule of work item 9 b, 630 a 50 ka tpmccb items are as per schedule of work item 9 c, 800 a 50 ka tpmccb items are as per schedule of work item 9 d, making suitable modification replacement of overheated existing aluminium bus bar links suitable to fit 630 800ampcapacity tp mccb i c cutting bending pvc sleeving testing commissioning etc complete as per site requirement items are as per schedule of work item 10, dismantling and replacement of existing worn out faulty paddle type water flow switch at different floors levels i c installation testing and commissioning with micro switch contacts and retard mechanism complete in all respects as required items are as per schedule of work item 11, attending leakage in the existing chilled water pipeline of various diameters including cutting of damaged portion edge preparation welding testing and making the pipeline operational including providing and fixing necessary scaffolding ladders safety arrangements for working at heights ranging from 15 feet to 100 feet in shaft area cleaning the pipe surface applying anti corrosive paint on welded joints and restoring the system to its original condition complete as required items are as per schedule of work item 12, replacement of the following items of existing electrical panels i c identifying and rectifying the fault dismantling of existing defective parts fixing connections testing etc as required a mnx 32 contactor make l andt ac plant room items are as per schedule of work item 13 a, mnx 25 contactor make l andt items are as per schedule of work item 13 b, 2noplus2 nc add on block make l andt items are as per schedule of work item 13 c, overload relay mn 2 of range 9 to 15 amps make l andt items are as per schedule of work item 13 d, single phase preventer items are as per schedule of work item 13 e, on off push button with elements items are as per schedule of work item 13 f, led indication lamp r y b g items are as per schedule of work item 13 g, 3 way selector switch items are as per schedule of work item 13 h, star delta timer items are as per schedule of work item 13 i, digital voltmeter make select or ss items are as per schedule of work item 13 j, digital ammeter make select or ss items are as per schedule of work item 13 k, v belt items are as per schedule of work item 13 l, painting of existing old electrical panel without dismantling including masking covering of indicators meters switches surface cleaning rust removal 1 coat red oxide primer plus synthetic enamel spray paint and finishing etc as required items are as per schedule of work item 14


Tender Value : 7391777
Due Date : May 19, 2026
T18 Ref No : 14942175
Source : GEM Tenders

corrigendum tender for supply of cassette ac, 3.0 tr bee 5-star inverter ac , supply of hi-wall split ac, 1.5 tr bee 5-star inverter ac , supply of hi-wall split ac, 1.0 tr bee 5-star inverter ac , installation of 3.0 tr cassette ac , installation of 1.5 or 1.0 tr hi-wall split ac , supply and installation of copper refrigerent for 3.0 tr cassette acs , supply and installation of copper refrigerent pipes for 1.5 or 1.0 tr sacs , supply and installation of interconnecting wires for 3.0 tr cassette acs , supply and installation of interconnecting wires for 1.5 or 1.0 tr hi-wall split acs , supply and installation of 25 mm pvc drain pipes , supply and installation of ms angle for outdoor units , supply and installation of 4kva stabliser , supply and installation of 5.0 kva stabliser, air conditioning work at sbi ghorahwa branch nichlaul maharajganj in new premises branch shifting, supply of 3.0 tr cassette type ac bee rated (2024 model) 5-star inverter technology air conditioner with full function wireless remote and auto restart feature, with indoor/outdoor unit, gas charge, copper condenser coils and copper cooling coils company provided copper refrigerant pipe complete in all respects., supply of 1.5 tr hi wall type bee rated (2024 model) 5-star inverter technology split air conditioner with full function wireless remote and auto restart feature, with indoor/outdoor unit, gas charge, copper condenser coils and copper cooling coils company provided copper refrigerant pipe complete in all respects., supply of 1.0 tr hi wall type bee rated (2024 model) 5-star inverter technology split air conditioner with full function wireless remote and auto restart feature, with indoor/outdoor unit, gas charge, copper condenser coils and copper cooling coils company provided copper refrigerant pipe complete in all respects., installation, testing and commissioning of 3.0 tr cassette air conditioner/ old ac dismantled from branch with wall cutting/ mounting, stabiliser and making good of damages complete in all respects., installation, testing and commissioning of 1.5 or 1.0 tr hi wall type split air conditioner/ old ac dismantled from branch with wall cutting/ mounting, stabiliser and making good of damages complete in all respects., supply, installation, testing and commissioning of insulated copper refrigerant piping set (suction and discharge) duly insulated by nitrile rubber for suitable for3.0 tr cassette ac., supply, installation, testing and commissioning of insulated copper refrigerant piping set (suction and discharge) duly insulated by nitrile rubber suitable for 1.5 or 1.0 tr split ac., supply, installation, testing and commissioning of inter connecting wiring/ cabling between indoor and outdoor of 3.0 tr cassette ac., supply, installation, testing and commissioning of inter connecting wiring/ cabling between indoor and outdoor of 1.5 or 1.0 tr hi wall split ac., supply, installation, testing and commissioning of pvc 25 mm water pipe with accessories and taking care to prevent leakages, for water drainage in concealed manner either on wall or under floor including making good of damages., supply and installation of robust ms angle, ms flat fabricated floor/ wall mounting stand suitable for outdoor units of cassette/split acs, painted with one coat of primer and two coats of synthetic enamel outdoor type paint including its grouting and making good of damages., supply & installation of 4.0 kva, wall mounted hi lo cut off stabiliser with tdr, voltage range 130-280v, complete in all respects., supply & installation of 5.0 kva, wall mounted hi lo cut off stabiliser with tdr, voltage range 130-280v, complete in all respects.


Agency / Dept : state bank of india SBI
Tender Value : 0
Due Date : Apr 09, 2026
T18 Ref No : 15031801
Location : kharagpur , west bengal

corrigendum tender for supply of split air-conditioner, supply of split air-conditioner of bee 5-star rating, suitable for cooling capacity for the whol e range of 5201 to 6860w (2 ton) with the function of cooling only, with rotary compressor, inverter (varia ble speed) type, suitable for 230v ac, 50 hz system, with 100% copper coil, eco friendly refrigerant, anti- freeze thermostat, with thermal protection for blower motor & condenser motor. conforming to bis specifi cation no. is:1391 (part-2) 2023. bee 5-star rating must comply to ministry of power notification no. s.o. 38 97(e) dated 29th october 2019 for table 3.2(f) with minimum indian seasonal energy efficiency ratio of 5. 0 (applicability date extended by notifications no. s.o. 4485(e) dated 10th december, 2020 and no. s.o. 46 34(e) dated 10th november, 2021). complying to ministry of power notification no. s.o. 2528(e) dated 8th august 2017 for other requirements. refrigerant copper pipes (suction & return) of minimum 4-meter lengt h each, nitrile rubber tube with density 55 kg/cubic meter or more, fire performance class 1, rate of burn ing class v-0, water vapour diffusion resistance factor more than 12000, service temperature 10 to 105-de gree c, surface flame spread class 1 & thickness of minimum inch, relevant test certificates to be submitte d. nitrile rubber tube shall be with suitable inner diameter to suit & to wrap the complete length of refriger ant copper pipe and aluminium foil lamination of 0.2 mm thick to cover entire length of the copper refriger ant pipes, outdoor unit stand and spare pcb circuit will be supplied along with each air-conditioner. any in dian is make - blue star ,lloyd, godrej ,carrier ,daikin voltas etc. detailed specifications attached as annex ure-a. - warranty period: 12 months after the date of delivery pl code : 429000920016


Tender Value : 0
Due Date : Apr 22, 2026