Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Ahu filter Tenders List

Latest Ahu filter Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Ahu filter tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Ahu filter tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Ahu filter Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Ahu filter tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Ahu filter Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Ahu filter Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Ahu filter Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Ahu filter tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Ahu filter Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Ahu filter sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Ahu filter tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Ahu filter tenders.

Is EMD mandatory for all Ahu filter tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Ahu filter work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Ahu filter tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Ahu filter Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15062995
Location : krishna , andhra pradesh
Source : GEM Tenders

Tender Value : 0
Due Date : Apr 27, 2026
T18 Ref No : 15247132
Location : new delhi , delhi
Source : GEM Tenders

tender for operation of microprocessor based hvac system , all inclusive comprehensive maintenance , replacement of damaged and worn out control and power wiring , dismantling and replacement of existing faulty 2 amp dp mcb , dismantling and replacement of existing faulty mpcb ms 116 , replacement of burnt broken and rusted terminal block , dismantling and replacement of following sizes of existing worn out faulty pipe 200mm dia 32 mm thick insulation , 150mm dia 32 mm thick insulation , 125mm dia 32 mm thick insulation , 100mm dia 32 mm thick insulation , 80mm dia 32 mm thick insulation , 65mm dia 32 mm thick insulation , dismantling and replacement of following sizes of existing worn out ndustrial type pressure gauges , providing and fixing in position the mercury in glass industrial type thermometers , butterfly valve manual with c i body ss disc a 150 mm dia , 100 mm dia , dismantling and replacement of following existing worn out faulty tpmccb 100 a 16 ka tpmccb , 200 a 25 ka tpmccb , 630 a 50 ka tpmccb , 800 a 50 ka tpmccb , making suitable modification replacement of overheated existing aluminium bus bar , dismantling and replacement of existing worn out faulty paddle type water flow , attending leakage in the existing chilled water pipeline , replacement of the following items of existing electrical panels mnx 32 contactor make l andtac plant room , mnx 25 contactor make l andt , 2noplus2 nc add on blockmake l andt , overload relay mn 2 of range 9 to 15 amps make l andt , single phase preventer , on off push button with elements , led indication lampr y b g , 3 way selector switch , star delta timer , digital voltmetermake select or ss , digital ammeter make select or ss , v belt , painting of existing old electrical panel, om hvac bsb janpath nd, operation of microprocessor based hvac system of capacity 5 x 100 tr chilling machines with screw compressors and air cooled condensers as detailed in annexure a and ductable tower type split ac and split ac as detailed in annexure b by deputing the following staff \n skilled semi skilled unskilled \n6 am to 2pm 1 1 2\n2 pm to 10 pm 1 1 2\ngeneral shift 9 am to 5 pm 1 0 0\nnotes \n1 staff may be asked to work in any shift and any day without any extra cost \n2 bill processed receipt proof online salary transfer account epf esi contr presently 12 perct and 3 25 perct ofpay respas reqt \n3 if esi and epf contributions rescission work initiated \n4 staff deployed enrolled attendance system\n5 the contractor ensure personnel meet defined standards f\n6 operation of the pumps 7 operation of ahus and tfa \n8 oper electrical panels\n9 recording readings chillers ahus pumps digital temperature meter \n10 to attend the floor complaints \n11 weekly washing ahus filters and ahus room\n12 chemical cleaning ahus cooling coil\n13 general checking testing and attending minor faults 14 out of skill manpower one skill operator electrician\n15 to carry out leak test compressors condenser coil with soap items are as per schedule of work item 1, all inclusive comprehensive maintenance of following items as per inventory at per annexure b given in relevant sections up to the required standards etc as per specification the items are \n1 ductable ac units\n2 tower split ac units\n3 split ac units \n items are as per schedule of work item 2, replacement of damaged and worn out control and power wiring of star delta starter panel for one motor in existing ahus electrical panel with new pvc insulated copper conductor wires of suitable size including providing and fixing of thimbles ferrules and new insulated fiber sheet for proper insulation removing of existing contactors cleaning and re fixing the same in position after proper checking and tightening of all connections complete as required items are as per schedule of work item 3, dismantling and replacement of existing faulty 2 amp dp mcbs in existing star delta starter panels of chilled water pumps on both primary and secondary sides i c testing etc complete as required items are as per schedule of work item 4, dismantling and replacement of existing faulty mpcb ms 116 in existing star delta starter panels of chilled water pumps on both primary and secondary sides i c testing etc complete as required items are as per schedule of work item 5, replacement of burnt broken and rusted terminal block 63 amp rating along with 2 nos lugs in the existing electrical panel of ahu s chilled water pump s etc complete as required items are as per schedule of work item 6, dismantling and replacement of following sizes of existing worn out faulty pipe at different floors levels i c supplying laying fixing testing and commissioning of nominal sizes of chilled water piping inside the building with necessary clamps vibration isolators and fittings but excluding valves strainers gauges etc duly insulated with following closed cell elastometric nitrile rubber of minimum 45 kg cu m density thermal conductivity 0 037 w mk or better at 20 deg mean temperature class o insulation applied by suitable adhesive complete including repairing of damage to building etc as per specifications and as required complete in all respect \nnote the pipes of sizes 150mm and below shall be m s c class as per is 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is 3589 from minimum 6 35mm thick m s sheet for pipes upto 350 mm dia and from minimum 7mm thick ms sheet for pipes of 400 mm dia and above \na 200mm dia 32 mm thick insulation items are as per schedule of work item 7 a, 150mm dia 32 mm thick insulation items are as per schedule of work item 7 b, 125mm dia 32 mm thick insulation items are as per schedule of work item 7 c, 100mm dia 32 mm thick insulation items are as per schedule of work item 7 d, 80mm dia 32 mm thick insulation items are as per schedule of work item 7 e, 65mm dia 32 mm thick insulation items are as per schedule of work item 7 f, dismantling and replacement of following sizes of existing worn out faulty components at different floors levels i c supplying fixing testing and commissioning of valves gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications 8 1 providing and fixing in position the industrial type pressure gauges with gun metal brass valves complete as required items are as per schedule of work item 8 1, providing and fixing in position the mercury in glass industrial type thermometers items are as per schedule of work item 8 2, butterfly valve manual with c i body ss disc nitrile rubber seal and o ring pn 16 pressure rating for chilled water hot eater circulation as specified a 150 mm dia items are as per schedule of work item 8 3 a, 100 mm dia items are as per schedule of work item 8 3 b, dismantling and replacement of following existing worn out faulty tpmccb at different floors levels i c fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel making connections ics100 perc icu and operational voltage 690v etc as required 100 a 16 ka tpmccb items are as per schedule of work item 9 a, 200 a 25 ka tpmccb items are as per schedule of work item 9 b, 630 a 50 ka tpmccb items are as per schedule of work item 9 c, 800 a 50 ka tpmccb items are as per schedule of work item 9 d, making suitable modification replacement of overheated existing aluminium bus bar links suitable to fit 630 800ampcapacity tp mccb i c cutting bending pvc sleeving testing commissioning etc complete as per site requirement items are as per schedule of work item 10, dismantling and replacement of existing worn out faulty paddle type water flow switch at different floors levels i c installation testing and commissioning with micro switch contacts and retard mechanism complete in all respects as required items are as per schedule of work item 11, attending leakage in the existing chilled water pipeline of various diameters including cutting of damaged portion edge preparation welding testing and making the pipeline operational including providing and fixing necessary scaffolding ladders safety arrangements for working at heights ranging from 15 feet to 100 feet in shaft area cleaning the pipe surface applying anti corrosive paint on welded joints and restoring the system to its original condition complete as required items are as per schedule of work item 12, replacement of the following items of existing electrical panels i c identifying and rectifying the fault dismantling of existing defective parts fixing connections testing etc as required a mnx 32 contactor make l andt ac plant room items are as per schedule of work item 13 a, mnx 25 contactor make l andt items are as per schedule of work item 13 b, 2noplus2 nc add on block make l andt items are as per schedule of work item 13 c, overload relay mn 2 of range 9 to 15 amps make l andt items are as per schedule of work item 13 d, single phase preventer items are as per schedule of work item 13 e, on off push button with elements items are as per schedule of work item 13 f, led indication lamp r y b g items are as per schedule of work item 13 g, 3 way selector switch items are as per schedule of work item 13 h, star delta timer items are as per schedule of work item 13 i, digital voltmeter make select or ss items are as per schedule of work item 13 j, digital ammeter make select or ss items are as per schedule of work item 13 k, v belt items are as per schedule of work item 13 l, painting of existing old electrical panel without dismantling including masking covering of indicators meters switches surface cleaning rust removal 1 coat red oxide primer plus synthetic enamel spray paint and finishing etc as required items are as per schedule of work item 14


Tender Value : 7391777
Due Date : May 19, 2026
T18 Ref No : 15123025
Location : nagpur , maharashtra
Source : GEM Tenders

tender for floor mounted dx type double skinned ahu , air cooled outdoor vrf units , ahu connection kit , hepa filter plenum laminar air flow system , gi ducting for tb lab , indoor ducting thermal insulation , exposed ducting thermal insulation , acoustic insulation for ducting , ahu control unit for tb lab , manual fire damper with fusible link , volume control damper , return air aluminum grill , 4 core x 16mm aluminum conductor armored cable , 4 core x 10mm sq copper conductor armored cable , 4 core x 4mm sq copper conductor armored cable , 18 gauge raceway with cover 150x50mm , 18 g cable tray 150 x 50 mm wo cover and acc , abc 6 kg fire extinguisher , co2 4 point 5 kg fire extinguisher , emergency evacuation plan , 2x1 point 5 sq mm frls armoured cable , existing system modification , leak detection system , air sampling probes , wall mounted eye washer , air shower for entry exit , class ii type a2 biosafety cabinet , class ii type b2 biosafety cabinet , high capacity exhaust fan , autoclave room exhaust fan , pantry exhaust fan , pressure monitoring system , pressure relief damper , pressure interlocking system plc , variable air volume vav unit , motorized volume control dampers , bag in bag out hepa filtration system , data loggers , alarm system , mdb panel , electrical power cabling copper armoured 4c x 4 sqmm , electrical power cabling copper armored 4c x 6 sqmm , electrical power cabling copper armoured 4c x 10 sqmm , electrical power cabling copper armoured 4c x 1point 5 sqmm cu shielded cable , supply installation testing and commissioning of conduit 2x2 point 5 sqmm 1x1point 5 sqmm for earthing , supply installation testing and commissioning of conduit 2x4 sqmm 1x2 point 5 sqmm for earthing , 25 mm ms conduit , 32 mm pvc conduit , earthing strip with accessories 25x6 mm , supply and laying of 8 swg earthing wire , supply laying and termination of 3 point 5x50 sqmm xlpe aluminium armoured cable , gi perforated cable trays 100 mm wide x 50 mm depth x 1point 6 mm thickness , raceway 150 mm wide x 50 mm depth x 1 point 6 mm thickness , switch socket 6 modular box 16 amp switch socket 6 amp , providing and laying cat 6 6 pair cable with accessories , supply and fixing of 4 way tpn horizontal db box with accessories , supply and fixing of 63 amp isolator , supply and fixing of 63 amp rccb , supply and fixing of 16 amp mcb , supply and fixing of 40 amp rccb , supply and fixing of 100 amp isolator , supply and fixing of 100 amp rccb , scaffolding , supply installation testing and commissioning of ups 20 kva with isolation transformer , supply installation testing and commissioning of 2x2 clean room luminaries , dismantling aluminium gypsum partitions doors windows fixed , dismantling tile work in floors and roofs 10 25 mm thick , cement concrete flooring 124 mix 40 mm thick , modular walls with 60 mm thick puf panels , modular ceiling with 60 mm thick puf panels , epoxy flooring 5 mm thick , aac block masonry 150 230 300 mm thick , 12 mm cement plaster 1 4 mix , vitrified tile 600x600 mm , pvc flooring , plaster of paris putty 2 mm thick , wall painting with acrylic emulsion , granite stone slab for platforms , extra for granite facia drops , extra for openings in granite for sinks , reinforced cement concrete work , centering and shuttering for shelves , steel reinforcement for rcc , stainless steel kitchen sink 610x510 mm , cp brass waste coupling 32 mm , coat hook with bracket , 600 mm long towel rail , cp brass angular stop cock , cp brass bottle trap 32 mm , upvc connection pipe with brass unions , c p sink cock with regular swinging spout table mounted model , c p brass extension nipple 15mmx50mm , stainless steel cabinets under counter and overhead , storage cabinets under counter and overhead , hermetically sealed swing door 900mm w x 2100mm , hermetically sealed swing door 1500mm w x 2100mm h , flush door shutters isi marked non decorative 35mm thick , extra for lipping with teak wood battens 25mm minimum depth , extra for vision panel not exceeding 0 point1 sqm rectangular or square , laminated sheet , h type stainless steel pull handle 304 grade 25x600mm , aluminium extruded section body tubular type universal hydraulic door closer , pair design lever handle on roses and escutcheons with mortise sash lock , dgu glass 1200mm x 1400mm , pass box 580 x 650 x 700 mm id 1 , pass box 230 x 230 x 295 mm id 1 , aluminium work for fixed portions polyester powder coated 50 micron , aluminium shutters for doors windows , glazing in aluminium frames 5mm float glass , pre laminated particle board for panelling 12mm thick , removal and refixing mineral fibre false ceiling tiles 595x595mm , cpvc pipes 15mm nominal dia hot cold water , cpvc pipes 20mm nominal dia hot and cold water , cutting holes in rcc floors roofs up to 15x15cm for drain pipes , trap self cleansing 100mm inlet outlet sand cast iron s and s , trap self cleansing 100mm inlet 75mm outlet sand cast iron s and s , glazed stoneware pipes class sp 1 100mm 1 is1 cement mortar , demolishing cement concrete 136 or richer , cement concrete work up to plinth level 124 mix , square mouth sw gully trap class sp 1 100x100mm p type , corner coving , steel work in built up tubular trusses hot finished, as per specification and scope of work


Tender Value : 21837572
Due Date : May 13, 2026
T18 Ref No : 15184501
Location : koraput , odisha
Source : GEM Tenders

tender for 652-15675 , 652-15674 , 652-15679 , 652-15680 , 652- m3094 , 652-15676 , 652-15677 , 652-m4958 , 652-m4959 , 652-m4960 , 652-m4962, filters for ac units, hepa filter for ahu\ntype flange type\nsize 610 x 610 x 305 mm - flange end\ncasing size 540 x 540 mm\ngrade h13\ncasing moc aluminum\nair flow greater than or equal to 2000 cfm 30 +/- 10 mm wc\nefficiency 99.9 % at 0.3 micron\nlocking flange center hole\naluminum fins to be provided\nreliable quality in line with iso. en. ul and ashrea, secondary / fine filter for ahu\ntype flange type\nsize 610 x 610 x 305 mm \ncasing size 540 x 540 mm\ngrade 7\ncasing moc gi / aluminum\nair flow greater than or equal to 2000 cfm 7.50 mm wc\nefficiency 97 % at 3 micron\nlocking flange center hole\naluminum mesh to be provided\nreliable quality in line with iso. en. ul and ashrea, secondary / fine filter for ahu\ntype flange type\nsize 590 x 590 x 300 mm\ncasing size 530 x 530 mm\ngrade 7\ncasing moc gi / aluminum\nair flow greater than or equal to 2000 cfm 7.50 mm wc\nefficiency 97 % at 3 micron\nlocking flange center hole\naluminum mesh to be provided\nreliable quality in line with iso. en. ul and ashrea, secondary / fine filter for ahu\ntype flange type\nsize 590 x 285 x 300 mm\ncasing size 530 x 220 mm\ngrade 7\ncasing moc gi / aluminum\nair flow greater than or equal to 1000 cfm 7.50 mm wc\nefficiency 97 % at 3 micron\nlocking flange center hole\naluminum mesh to be provided\nreliable quality in line with iso. en. ul and ashrea, pre-filter for ahu\ntype cassette / box type (plane end)\nsize 550 x 540 x 50 mm \ncasing moc gi / aluminum\nair flow greater than or equal to 2000 cfm \nefficiency 90 % down to 10-20 micron \naluminum mesh to be provided\nreliable quality in line with iso. en. ul and ashrea, pre-filter for ahu\ntype cassette / box type (plane end)\nsize 595 x 595 x 48 mm \ncasing moc gi / aluminum\nair flow greater than or equal to 2000 cfm \nefficiency 90 % down to 10-20 micron \naluminum mesh to be provided\nreliable quality in line with iso. en. ul and ashrea, pre-filter for ahu\ntype cassette / box type (plane end)\nsize 595 x 285 x 48 mm \ncasing moc gi / aluminum\nair flow greater than or equal to 1000 cfm \nefficiency 90 % down to 10-20 micron \naluminum mesh to be provided\nreliable quality in line with iso. en. ul and ashrea, return air filter for tfa\ntype cassette / box type (plane end)\nsize 590 x 590 x 25 mm \ncasing moc gi / aluminum\nair flow greater than or equal to 2000 cfm \nefficiency 90 % down to 20 micron \naluminum mesh to be provided\nreliable quality in line with iso. en. ul and ashrea, return air filter for tfa\ntype cassette / box type (plane end)\nsize 590 x 290 x 25 mm \ncasing moc gi / aluminum\nair flow greater than or equal to 1000 cfm \nefficiency 90 % down to 20 micron \naluminum mesh to be provided\nreliable quality in line with iso. en. ul and ashrea, fresh air inlet filter for tfa\ntype multi pocket bag filter\nfilter moc synthetic\nframe/header size (wxh) 590 x 590\nheader thickness(hd) 25 mm \ncasing moc gi / aluminum\nlength of pocket 600 mm\nno of pocket 6 or 8\nair flow greater than or equal to 2000 cfm \nefficiency greater than or equal to 80 % down to 10 - 20 micron \nfiltration class f-7 or f-8 \nfinal pressure drop less than or equal to 450 pa\noperating temperature greater than 70 deg. c\nreliable quality in line with iso. en. ul and ashrea, filter mesh fabric for air conditioner\nmaterial polypropylene / polyester\ncleaning water washable\ntype non wooven plane type\ncolour white\nwidth 1 to 1.5 mtr\nthickness greater than or equal to 10 mm\nweight greater than or equal to 80 gsm\ndelivery packing in roll\nno of roll 2 to 4 \nair permeability greater than or equal to 3000 l/sq.m\nair flow rate greater than or equal to 0.5 cubic m/s\ninitial / final resistance greater than or equal to 20/120 pa\nmax. operating temp. 100 deg. c\nreliable quality in line with iso. en. ul and ashrea


Tender Value : 0
Due Date : May 20, 2026