Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Ac pipeline repair Tenders List

Latest Ac pipeline repair Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Ac pipeline repair tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Ac pipeline repair tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Ac pipeline repair Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Ac pipeline repair tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Ac pipeline repair Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Ac pipeline repair Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Ac pipeline repair Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Ac pipeline repair tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Ac pipeline repair Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Ac pipeline repair sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Ac pipeline repair tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Ac pipeline repair tenders.

Is EMD mandatory for all Ac pipeline repair tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Ac pipeline repair work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Ac pipeline repair tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Ac pipeline repair Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15003213
Location : rupsi , assam
Source : GEM Tenders

tender for operation and maintenance of electrical and mechanical installations , job contract for operation and day to day maintenance services of airport systems equipments , execution of item of schedule of rates cpwd dsr 2022 as and when required , testing of transformer oil sample including conducting bdv test and submission of test report etc complete as required , filtration of transformer oil of 630 kva transformer , servicing and checking of lt air circuit breaker , servicing and checking of ht vacuum circuit breaker , calibration and testing of relays at ht panel , calibration and testing of following relays at lt and synchronizing panel , scrubbing, cleaning the existing surface of cubicle panel, feeder pillars and painting , lettering of maximum 2 inch size alphabetic or numerical , cleaning the surface of ms chequered plates , supply and replacement of silica gel in breather of existing 630 kva transformer etc. complete as required , lifting and lowering of 10 hp borewell submersible motor pump set , servicing and complete overhauling of 10 hp borewell submersible motor pump set , decoration of terminal building and canopy of rupsi airport , supply and replacement of defective smoke detectors , supply and replacement of defective manual call point , supply of convertor or driver suitable for philips make 20 w downlight types led luminaires or fittings , supply of convertor or driver suitable for osram make 120w types led luminaires or fittings , supply of convertor or driver suitable for havells make 18 or 20 w downlight types led luminaires or fittings , supply of convertor or driver suitable for wipro make 36w 2ftx2ft recess mounted fitting , supply of 1000w 240v lamp suitable for aerodrome beacon , supply of aerodrome beacon , calibration of clinometer , supply of reflector suitable for ama make papi , supply of 2c x 4 sq mm. secondary lead with plug , supply of b connector or four way porcelain terminal , supply of 5 kv grade 50 hz ac isolating transformer , supply of two pin halogen lamp holder suitable for 200 watt , supply of 5 w screw cap led lamp , supply of wind sock cloth , supply and replacement of led flood light , supply and replacement of obstruction light of wind direction indicator , supply and replacement of 180 ah 12 v lead acid battery , supply and replacement of 100 ah 12 v lead acid battery , supply of automaic electric hand drier , servicing, checking repairing overhauling and testing of crompton make 630 kva transformer, annual operation and maintenance of electrical and mechanical works at rupsi airport, operation and maintenance of electrical and mechanical installations of operational and non operational areas including terminal buildling, ats building, fire station, electrical substation and other ancillary buildings for round the clock operation on all days including sundays and holidays by engaging following manpower along with providing required tool and consumables as specified in special conditions of contract for day to day maintenance except spares. the job includes preventive, routine maintenance, attending complaint or fault or breakdown by taking rectification action\nensuring serviceability and satisfactory working condition of the system, maintaining all records and documentation etc. complete as per agreement conditions and as per the instruction of eic.\n1. supervisor (highly skilled) - 01 no.\n2. document assistant (highly skilled) - 01 no.\n3. wireman (skilled) - 07 nos.\n4. semi-skilled- 06 nos.\n5. helper (unskilled) - 03 nos.\n(the above manpower is excluding reliever), job contract for operation and day to day maintenance services of airport systems equipments including scctv camera system, fids , pa system, hhmd, dfmd, security equipments, bdds equipments, xbis machines, etd equipment etc. installed at terminal building, ancillary building at rupsi airport. job also includes attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, providing registers and log books as per formats given in tender document and maintenance of daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, registers and log books and coordination with oem technicians during cmc works etc. by deploying following manpowers as per scope of work given in special conditions of contract shall be ensured round the clock (ie. in one shifts basis) on all days including sundays & national holidays as per direction of eic and as per attached annexure-a of atc. \n1. supervisor (high skilled) -01 no. \n2. technician ( skilled) -01 no. (the above manpower is excluding reliever), execution of item of schedule of rates cpwd dsr 2022 as and when required for attending breakdown, repair and maintenance and upkeep of internal & external electrical installations as per direction of e-i-c at different locations of operational and non operational area i/c terminal building, ats building, fire station, electrical substation and other ancillary buildings etc. the bidder shall quote the rate in inr only including price escalation for 01 year for the job corresponding to an amount of rs. 1,00,000.00 (including gst from dsr 2022 items) and percentage (%) above/below shall be calculated by aai and paid accordingly., testing of transformer oil sample including conducting bdv test and submission of test report etc.\ncomplete as required, filtration of transformer oil of 630 kva transformer to attain acceptable di-electric strength by hot streamline process including arrangement of plant/machine, transportation etc. complete as required by topping of transformer oil and bdv testing including submission of test reports before & after dehydration of oil. (excluding cost of transformer oil) (item is to be executed if the bdv value of transformer oil is found below the stipulated value)., servicing & checking of lt air circuit breaker (acb) of l&t u power omega make by deploying authorised service personnel of manufacturer/ oems service dealers as per oems standards complete as required and submission of service reports., servicing & checking of ht vacuum circuit breaker (vcb) of siemens make by deploying authorised service personnel of manufacturer/oems service dealers as per oems standards complete as required and submission of service reports., calibration and testing of following relays at ht panel by deploying authorised service personnel of manufacturer/oems service dealers as per oems standards complete as required and submission of service reports.\ni) vamp 57 - 5 nos. (numerical type of schneider make)\nii) vajh13 - 5 nos. (tripping relay of alstom make)\niii) vax31 - 5 nos. (trip circuit supervision relay of alstom make)\niv) vaa33 - 4 nos. (auxiliary relay of alstom make), calibration and testing of following relays at lt & synchronizing panel by deploying authorised service personnel of manufacturer/oems service dealers as per oems standards complete as required and submission of service reports.\ni) vajh13 - 2 nos. (tripping relay of alstom make)\nii) vax31 - 2 nos. (trip circuit supervision relay of alstom make)\niii) ccum21pf112a - 2 nos. (definite time reverse power relay of areva make)\niv) cag14af15a - 2 nos. (instantaneous earth fault relayof alstom make), scrubbing, cleaning the existing surface of cubicle panel, feeder pillars & painting the same with one coat of primer and one coat of synthetic enamel paint of approved colour etc. complete as required, lettering of maximum 2inc size (alphabetic / numerical) on the finished painted surface of feeder pillar / panel / earth pits with synthetic enamel paint of approved colour etc. complete as required., cleaning the surface of ms chequered plates and painting with one coat of primer and two coats of synthetic enamel black paint etc. complete as required., supply and replacement of silica gel in breather of existing 630 kva transformer etc. complete as required, lifting and lowering of 10 hp borewell submersible motor pump set along with dismantling of complete delivery pipeline, removal of pump sets, disconnection of flexible submersible cable, reassembling of submersible pump, complete delivery pipeline, fixing / laying of existing submersible cable including electrical connection, testing and commissioning etc. complete as required., servicing and complete overhauling of 10 hp borewell submersible motor pump set including replacement of defective bearing, coupling, impellar, mechanical & oil seal, heat varnishing of motor etc. complete as required, decoration of terminal building and canopy of rupsi airport, in tri-colour, with the following lighting items of pattern approved by e-i-c or his authorized representative, for 03 days etc. complete as required.\ni) 60 nos. led series lighting chain (minimum chain length 5m and uniform spacing between chains not more than 0.75 m)\nii) 20 nos. rgb led facade/ disco/ flood light fittings (minimum 10000 lumen output), supply and replacement of defective smoke detectors of suitable make & model compatible to the\nexisting system., supply and replacement of defective manual call point of suitable make & model compatible to the existing system, i) philips make 20 w downlight type dn195b led20s, ii) osram make 120w type. ledenvo led street light, iii) havells make 18/20 w downlight, iv) wipro make 36w 2ftx2ft recess mounted fitting, supply of 1000w , 240v lamp suitable for aerodrome beacon of model ab-1000f make- manairco inc as and when required., supply of aerodrome beacon of model ab-1000f make- manairco inc as and when required., calibration of clinometer from govt. test laboratory/ oem, submission of test report etc., complete as required i/c taking the equipment from aais site to laboratory and bringing back the same from laboratory to aais site., supply of reflector suitable for ama make papi fittings as and when required., supply of 2c x 4 sq mm. secondary lead with plug at one end of standard length of 5 m as and when required, supply of b - connector / four-way porcelain terminal for ama make papi units as and when required, supply of following rating 5 kv grade, 50 hz ac isolating transformer, series type, encapsuled in\npolyster resin, finally moulded in neoprene type rubber with primary and secondary leads, confirming to latest specifications as required suitable for airfield lighting applications etc. as and when required. 200 watt, 6.6/6.6 amp., supply of two pin halogen lamp holder suitable for 200 watt, 6.6 amp lamp as and when required., supply of 5 w screw cap led lamp suitable for landing t , efficacy not less than 100 lm/w as and when required., supply of wind sock cloth, 13 ft 9 inch length, colour preferably orange & white and conforming to icao annex-14 as and when required., supply and replacement of led flood light for mounting on wind direction indicator, equivalent to philips make model bvp132led16/cw 20w 100-240v wb in as and when required., supply and replacement of obstruction light of wind direction indicator as and when required., supply and replacement of 180 ah 12 v lead-acid battery, conforming to is 14257 1995 with up to date amendments, suitable for high cranking performance of 400 kva dg set as and when required., supply and replacement of 100 ah 12 v lead-acid battery, conforming to is 14257 1995 with up to date amendments, suitable for high cranking performance of 62.5 kva dg set as and when required, supply of automaic electric hand drier of following specifications or equivalent\nmake omco, model ipx1,voltage-220-240v, power 1800w, servicing, checking, repairing, overhauling and testing of crompton make 630 kva, 11/0.433 kv transformer including carrying out the following tests by deploying authorised service personnel of manufacturer/oems service dealers as per oems standards complete as required and submission of reports.\na) general inspection\nb) ir value test primary to secondary, primary to earth, secondary to earth\nc) votage ratio check at all tap position,\nd) buchholz relay operation\ne) oti operation\nf) wti operation\ng) on-load tap changer operation check\nh) cleaning of transformer and replacement of silica gel\ni) acidity check test of transformer oil.


Tender Value : 0
Due Date : May 04, 2026
T18 Ref No : 15229023
Location : rupsi , assam
Source : GEM Tenders

corrigendum tender for operation and maintenance of electrical and mechanical installations , job contract for operation and day to day maintenance services of airport systems equipments , execution of item of schedule of rates cpwd dsr 2022 as and when required , testing of transformer oil sample including conducting bdv test and submission of test report etc complete as required , filtration of transformer oil of 630 kva transformer , servicing and checking of lt air circuit breaker , servicing and checking of ht vacuum circuit breaker , calibration and testing of relays at ht panel , calibration and testing of following relays at lt and synchronizing panel , scrubbing, cleaning the existing surface of cubicle panel, feeder pillars and painting , lettering of maximum 2 inch size alphabetic or numerical , cleaning the surface of ms chequered plates , supply and replacement of silica gel in breather of existing 630 kva transformer etc. complete as required , lifting and lowering of 10 hp borewell submersible motor pump set , servicing and complete overhauling of 10 hp borewell submersible motor pump set , decoration of terminal building and canopy of rupsi airport , supply and replacement of defective smoke detectors , supply and replacement of defective manual call point , supply of convertor or driver suitable for philips make 20 w downlight types led luminaires or fittings , supply of convertor or driver suitable for osram make 120w types led luminaires or fittings , supply of convertor or driver suitable for havells make 18 or 20 w downlight types led luminaires or fittings , supply of convertor or driver suitable for wipro make 36w 2ftx2ft recess mounted fitting , supply of 1000w 240v lamp suitable for aerodrome beacon , supply of aerodrome beacon , calibration of clinometer , supply of reflector suitable for ama make papi , supply of 2c x 4 sq mm. secondary lead with plug , supply of b connector or four way porcelain terminal , supply of 5 kv grade 50 hz ac isolating transformer , supply of two pin halogen lamp holder suitable for 200 watt , supply of 5 w screw cap led lamp , supply of wind sock cloth , supply and replacement of led flood light , supply and replacement of obstruction light of wind direction indicator , supply and replacement of 180 ah 12 v lead acid battery , supply and replacement of 100 ah 12 v lead acid battery , supply of automaic electric hand drier , servicing, checking repairing overhauling and testing of crompton make 630 kva transformer, annual operation and maintenance of electrical and mechanical works at rupsi airport, operation and maintenance of electrical and mechanical installations of operational and non operational areas including terminal buildling, ats building, fire station, electrical substation and other ancillary buildings for round the clock operation on all days including sundays and holidays by engaging following manpower along with providing required tool and consumables as specified in special conditions of contract for day to day maintenance except spares. the job includes preventive, routine maintenance, attending complaint or fault or breakdown by taking rectification action\nensuring serviceability and satisfactory working condition of the system, maintaining all records and documentation etc. complete as per agreement conditions and as per the instruction of eic.\n1. supervisor (highly skilled) - 01 no.\n2. document assistant (highly skilled) - 01 no.\n3. wireman (skilled) - 07 nos.\n4. semi-skilled- 06 nos.\n5. helper (unskilled) - 03 nos.\n(the above manpower is excluding reliever), job contract for operation and day to day maintenance services of airport systems equipments including scctv camera system, fids , pa system, hhmd, dfmd, security equipments, bdds equipments, xbis machines, etd equipment etc. installed at terminal building, ancillary building at rupsi airport. job also includes attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, providing registers and log books as per formats given in tender document and maintenance of daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, registers and log books and coordination with oem technicians during cmc works etc. by deploying following manpowers as per scope of work given in special conditions of contract shall be ensured round the clock (ie. in one shifts basis) on all days including sundays & national holidays as per direction of eic and as per attached annexure-a of atc. \n1. supervisor (high skilled) -01 no. \n2. technician ( skilled) -01 no. (the above manpower is excluding reliever), execution of item of schedule of rates cpwd dsr 2022 as and when required for attending breakdown, repair and maintenance and upkeep of internal & external electrical installations as per direction of e-i-c at different locations of operational and non operational area i/c terminal building, ats building, fire station, electrical substation and other ancillary buildings etc. the bidder shall quote the rate in inr only including price escalation for 01 year for the job corresponding to an amount of rs. 1,00,000.00 (including gst from dsr 2022 items) and percentage (%) above/below shall be calculated by aai and paid accordingly., testing of transformer oil sample including conducting bdv test and submission of test report etc.\ncomplete as required, filtration of transformer oil of 630 kva transformer to attain acceptable di-electric strength by hot streamline process including arrangement of plant/machine, transportation etc. complete as required by topping of transformer oil and bdv testing including submission of test reports before & after dehydration of oil. (excluding cost of transformer oil) (item is to be executed if the bdv value of transformer oil is found below the stipulated value)., servicing & checking of lt air circuit breaker (acb) of l&t u power omega make by deploying authorised service personnel of manufacturer/ oems service dealers as per oems standards complete as required and submission of service reports., servicing & checking of ht vacuum circuit breaker (vcb) of siemens make by deploying authorised service personnel of manufacturer/oems service dealers as per oems standards complete as required and submission of service reports., calibration and testing of following relays at ht panel by deploying authorised service personnel of manufacturer/oems service dealers as per oems standards complete as required and submission of service reports.\ni) vamp 57 - 5 nos. (numerical type of schneider make)\nii) vajh13 - 5 nos. (tripping relay of alstom make)\niii) vax31 - 5 nos. (trip circuit supervision relay of alstom make)\niv) vaa33 - 4 nos. (auxiliary relay of alstom make), calibration and testing of following relays at lt & synchronizing panel by deploying authorised service personnel of manufacturer/oems service dealers as per oems standards complete as required and submission of service reports.\ni) vajh13 - 2 nos. (tripping relay of alstom make)\nii) vax31 - 2 nos. (trip circuit supervision relay of alstom make)\niii) ccum21pf112a - 2 nos. (definite time reverse power relay of areva make)\niv) cag14af15a - 2 nos. (instantaneous earth fault relayof alstom make), scrubbing, cleaning the existing surface of cubicle panel, feeder pillars & painting the same with one coat of primer and one coat of synthetic enamel paint of approved colour etc. complete as required, lettering of maximum 2inc size (alphabetic / numerical) on the finished painted surface of feeder pillar / panel / earth pits with synthetic enamel paint of approved colour etc. complete as required., cleaning the surface of ms chequered plates and painting with one coat of primer and two coats of synthetic enamel black paint etc. complete as required., supply and replacement of silica gel in breather of existing 630 kva transformer etc. complete as required, lifting and lowering of 10 hp borewell submersible motor pump set along with dismantling of complete delivery pipeline, removal of pump sets, disconnection of flexible submersible cable, reassembling of submersible pump, complete delivery pipeline, fixing / laying of existing submersible cable including electrical connection, testing and commissioning etc. complete as required., servicing and complete overhauling of 10 hp borewell submersible motor pump set including replacement of defective bearing, coupling, impellar, mechanical & oil seal, heat varnishing of motor etc. complete as required, decoration of terminal building and canopy of rupsi airport, in tri-colour, with the following lighting items of pattern approved by e-i-c or his authorized representative, for 03 days etc. complete as required.\ni) 60 nos. led series lighting chain (minimum chain length 5m and uniform spacing between chains not more than 0.75 m)\nii) 20 nos. rgb led facade/ disco/ flood light fittings (minimum 10000 lumen output), supply and replacement of defective smoke detectors of suitable make & model compatible to the\nexisting system., supply and replacement of defective manual call point of suitable make & model compatible to the existing system, i) philips make 20 w downlight type dn195b led20s, ii) osram make 120w type. ledenvo led street light, iii) havells make 18/20 w downlight, iv) wipro make 36w 2ftx2ft recess mounted fitting, supply of 1000w , 240v lamp suitable for aerodrome beacon of model ab-1000f make- manairco inc as and when required., supply of aerodrome beacon of model ab-1000f make- manairco inc as and when required., calibration of clinometer from govt. test laboratory/ oem, submission of test report etc., complete as required i/c taking the equipment from aais site to laboratory and bringing back the same from laboratory to aais site., supply of reflector suitable for ama make papi fittings as and when required., supply of 2c x 4 sq mm. secondary lead with plug at one end of standard length of 5 m as and when required, supply of b - connector / four-way porcelain terminal for ama make papi units as and when required, supply of following rating 5 kv grade, 50 hz ac isolating transformer, series type, encapsuled in\npolyster resin, finally moulded in neoprene type rubber with primary and secondary leads, confirming to latest specifications as required suitable for airfield lighting applications etc. as and when required. 200 watt, 6.6/6.6 amp., supply of two pin halogen lamp holder suitable for 200 watt, 6.6 amp lamp as and when required., supply of 5 w screw cap led lamp suitable for landing t , efficacy not less than 100 lm/w as and when required., supply of wind sock cloth, 13 ft 9 inch length, colour preferably orange & white and conforming to icao annex-14 as and when required., supply and replacement of led flood light for mounting on wind direction indicator, equivalent to philips make model bvp132led16/cw 20w 100-240v wb in as and when required., supply and replacement of obstruction light of wind direction indicator as and when required., supply and replacement of 180 ah 12 v lead-acid battery, conforming to is 14257 1995 with up to date amendments, suitable for high cranking performance of 400 kva dg set as and when required., supply and replacement of 100 ah 12 v lead-acid battery, conforming to is 14257 1995 with up to date amendments, suitable for high cranking performance of 62.5 kva dg set as and when required, supply of automaic electric hand drier of following specifications or equivalent\nmake omco, model ipx1,voltage-220-240v, power 1800w, servicing, checking, repairing, overhauling and testing of crompton make 630 kva, 11/0.433 kv transformer including carrying out the following tests by deploying authorised service personnel of manufacturer/oems service dealers as per oems standards complete as required and submission of reports.\na) general inspection\nb) ir value test primary to secondary, primary to earth, secondary to earth\nc) votage ratio check at all tap position,\nd) buchholz relay operation\ne) oti operation\nf) wti operation\ng) on-load tap changer operation check\nh) cleaning of transformer and replacement of silica gel\ni) acidity check test of transformer oil.


Tender Value : 0
Due Date : May 06, 2026